Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 41(7): 1256-1262, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32586967

RESUMO

BACKGROUND AND PURPOSE: Conventional single-shot FSE commonly used for fast MRI may be suboptimal for brain evaluation due to poor image contrast, SNR, or image blurring. We investigated the clinical performance of variable refocusing flip angle single-shot FSE, a variation of single-shot FSE with lower radiofrequency energy deposition and potentially faster acquisition time, as an alternative approach to fast brain MR imaging. MATERIALS AND METHODS: We retrospectively compared half-Fourier single-shot FSE with half- and full-Fourier variable refocusing flip angle single-shot FSE in 30 children. Three readers reviewed images for motion artifacts, image sharpness at the brain-fluid interface, and image sharpness/tissue contrast at gray-white differentiation on a modified 5-point Likert scale. Two readers also evaluated full-Fourier variable refocusing flip angle single-shot FSE against T2-FSE for brain lesion detectability in 38 children. RESULTS: Variable refocusing flip angle single-shot FSE sequences showed more motion artifacts (P < .001). Variable refocusing flip angle single-shot FSE sequences scored higher regarding image sharpness at brain-fluid interfaces (P < .001) and gray-white differentiation (P < .001). Acquisition times for half- and full-Fourier variable refocusing flip angle single-shot FSE were faster than for single-shot FSE (P < .001) with a 53% and 47% reduction, respectively. Intermodality agreement between full-Fourier variable refocusing flip angle single-shot FSE and T2-FSE findings was near-perfect (κ = 0.90, κ = 0.95), with an 8% discordance rate for ground truth lesion detection. CONCLUSIONS: Variable refocusing flip angle single-shot FSE achieved 2× faster scan times than single-shot FSE with improved image sharpness at brain-fluid interfaces and gray-white differentiation. Such improvements are likely attributed to a combination of improved contrast, spatial resolution, SNR, and reduced T2-decay associated with blurring. While variable refocusing flip angle single-shot FSE may be a useful alternative to single-shot FSE and, potentially, T2-FSE when faster scan times are desired, motion artifacts were more common in variable refocusing flip angle single-shot FSE, and, thus, they remain an important consideration before clinical implementation.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adolescente , Artefatos , Criança , Pré-Escolar , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Tempo
2.
Gene Ther ; 17(7): 827-38, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20237511

RESUMO

Transcriptional targeting for cardiac gene therapy is limited by the relatively weak activity of most cardiac-specific promoters. We have developed a bidirectional plasmid vector, which uses a two-step transcriptional amplification (TSTA) strategy to enhance the expression of two optical reporter genes, firefly luciferase (fluc) and Renilla luciferase (hrluc), driven by the cardiac troponin T (cTnT) promoter. The vector was characterized in vitro and in living mice using luminometry and bioluminescence imaging to assess its ability to mediate strong, correlated reporter gene expression in a cardiac cell line and the myocardium, while minimizing expression in non-cardiac cell lines and the liver. In vitro, the TSTA system significantly enhanced cTnT-mediated reporter gene expression with moderate preservation of cardiac specificity. After intramyocardial and hydrodynamic tail vein delivery of an hrluc-enhanced variant of the vector, long-term fluc expression was observed in the heart, but not in the liver. In both the cardiac cell line and the myocardium, fluc expression correlated well with hrluc expression. These results show the vector's ability to effectively amplify and couple transgene expression in a cardiac-specific manner. Further replacement of either reporter gene with a therapeutic gene should allow non-invasive imaging of targeted gene therapy in living subjects.


Assuntos
Amplificação de Genes , Marcação de Genes , Técnicas de Transferência de Genes , Vetores Genéticos , Plasmídeos , Regiões Promotoras Genéticas , Transgenes , Troponina/genética , Animais , Linhagem Celular , Feminino , Genes Reporter , Fígado/metabolismo , Luciferases de Vaga-Lume/genética , Luciferases de Renilla/genética , Camundongos , Camundongos Endogâmicos BALB C , Miocárdio/metabolismo , Transcrição Gênica
3.
Arch Biochem Biophys ; 381(2): 205-12, 2000 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-11032407

RESUMO

A bovine cartilage explant system was used to evaluate the effects of injurious compression on chondrocyte apoptosis and matrix biochemical and biomechanical properties within intact cartilage. Disks of newborn bovine articular cartilage were compressed in vitro to various peak stress levels and chondrocyte apoptotic cell death, tissue biomechanical properties, tissue swelling, glycosaminoglycan loss, and nitrite levels were quantified. Chondrocyte apoptosis occurred at peak stresses as low as 4.5 MPa and increased with peak stress in a dose-dependent manner. This increase in apoptosis was maximal by 24 h after the termination of the loading protocol. At high peak stresses (>20 MPa), greater than 50% of cells apoptosed. When measured in uniaxial confined compression, the equilibrium and dynamic stiffness of explants decreased with the severity of injurious load, although this trend was not significant until 24-MPa peak stress. In contrast, the equilibrium and dynamic stiffness measured in radially unconfined compression decreased significantly after injurious stresses of 12 and 7 MPa, respectively. Together, these results suggested that injurious compression caused a degradation of the collagen fibril network in the 7- to 12-MPa range. Consistent with this hypothesis, injurious compression caused a dose-dependent increase in tissue swelling, significant by 13-MPa peak stress. Glycosaminoglycans were also released from the cartilage in a dose-dependent manner, significant by 6- to 13-MPa peak stress. Nitrite levels were significantly increased above controls at 20-MPa peak stress. Together, these data suggest that injurious compression can stimulate cell death as well as a range of biomechanical and biochemical alterations to the matrix and, possibly, chondrocyte nitric oxide expression. Interestingly, chondrocyte programmed cell death appears to take place at stresses lower than those required to stimulate cartilage matrix degradation and biomechanical changes. While chondrocyte apoptosis may therefore be one of the earliest responses to tissue injury, it is currently unclear whether this initial cellular response subsequently drives cartilage matrix degradation and changes in the biomechanical properties of the tissue.


Assuntos
Apoptose , Cartilagem Articular/lesões , Cartilagem Articular/patologia , Condrócitos/patologia , Animais , Animais Recém-Nascidos , Cartilagem Articular/metabolismo , Bovinos , Colágeno/metabolismo , Marcação In Situ das Extremidades Cortadas , Técnicas In Vitro , Cinética , Estresse Mecânico
4.
J Biomech ; 33(11): 1523-7, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10940414

RESUMO

We have developed an incubator housed, biaxial-tissue-loading device capable of applying axial deformations as small as 1 microm and sinusoidal rotations as small as 0.01 degrees. Axial resolution is 50 nm for applying sinewaves as low as 10 microm (or 1% based on a 1 mm thickness) or as large as 100 microm. Rotational resolution is 0.0005 degrees. The machine is small enough (30 cm high x 25 cm x 20 cm) to be placed in a standard incubator for long-term tissue culture loading studies. In metabolic studies described here, application of sinusoidal macroscopic shear deformation to articular cartilage explants resulted in a significant increase in the synthesis of proteoglycan and proteins (uptake of (35)S-sulfate and (3)H-proline) over controls held at the same static offset compression.


Assuntos
Cartilagem Articular/fisiologia , Animais , Fenômenos Biomecânicos , Engenharia Biomédica/instrumentação , Cartilagem Articular/metabolismo , Bovinos , Técnicas de Cultura , Desenho de Equipamento , Prolina/metabolismo , Sulfatos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...