Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Ophthalmol ; 43(12): 5071-5078, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37874441

RESUMO

PURPOSE: To compare two approaches for the implantation of the PRESERFLO microshunt: an anterior approach (A) with a 6-8-mm peritomy and a posterior approach (P) with a 3-mm incision. METHODS: We retrospectively analyzed 126 patients who received a PRESERFLO microshunt. We compared intraocular pressure (IOP), surgical time, medication count, and postoperative complications over nine months. RESULTS: The baseline IOP was similar in A (21.8 ± 8.5 mm Hg) and P (23.9 ± 8.1 mm Hg) (p = 0.08). Surgical duration was significantly shorter in P (10 ± 0.4 min) than in A (26 ± 0.8 min) (p < 0.001). Postoperative IOP levels were comparable in A (10.8 ± 5.9 mm Hg) and P (10.6 ± 4.5 mm Hg) at 30 days (p = 0.62) and throughout the study (all intra-group p-values > 0.08). The preoperative medication count was 3.2 ± 1.3 drops in A and 3.3 ± 1.0 drops in P (p = 0.4). Postoperative values were 0.2 ± 0.6 in A and 0.3 ± 0.7 in P at nine months. There were no significant differences in complications and surgical revisions between groups (p-values > 0.05). CONCLUSION: Both techniques achieved satisfactory IOP and medication count reductions and had similar safety profiles, but the posterior incision technique was 2.6 times faster than the anterior incision technique.


Assuntos
Glaucoma de Ângulo Aberto , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/complicações , Estudos Retrospectivos , Pressão Intraocular , Tonometria Ocular , Implantação de Prótese
2.
Sci Rep ; 12(1): 10584, 2022 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-35732782

RESUMO

We investigated whether trabeculopuncture (TP) could detect distal outflow resistance to predict the outcome of canal-based glaucoma surgery such as ab interno trabeculectomy (AIT). These procedures have a high utilization in open angle glaucoma, but fail in eyes with an unidentified distal outflow resistance. We assigned 81 porcine eyes to two groups: trial (n = 42) and control (n = 39). At 24 h, four YAG-laser trabeculopunctures were placed nasally, followed by a 180° AIT at the same site at 48 h. The proportion of TP responders between both AIT groups was compared. Histology and outflow canalograms were determined. Both post-TP and post-AIT IOPs were lower than baseline IOP (p = 0.015 and p < 0.01, respectively). The success rates of TP and AIT were 69% and 85.7%, respectively. Sensitivity and specificity values of TP as predictive test for AIT success were 77.7% and 83.3%, respectively. The positive and negative predictive values were 96.6% and 38.5%, respectively. We conclude that a 10% reduction in IOP after TP can be used as a predictor for the success (> 20% IOP decrease) of 180° AIT in porcine eyes.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Trabeculectomia , Animais , Glaucoma/diagnóstico , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Suínos , Malha Trabecular/cirurgia , Trabeculectomia/métodos , Resultado do Tratamento
3.
Br J Ophthalmol ; 99(2): 258-62, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25170064

RESUMO

AIM: To evaluate outcomes of ab interno trabeculectomy (AIT) with the trabectome following failed trabeculectomy. METHODS: Prospective study of AITs and phaco-AITs after a failed trabeculectomy. The indication for AIT was intraocular pressure (IOP) above target on maximally tolerated therapy, and for phaco-AIT a visually significant cataract and need to lower IOP or glaucoma medications. Outcomes included IOP, medications, complications, secondary procedures and success, defined as IOP of less than 21 mm Hg and a greater than 20% reduction from baseline without further surgery. Exclusion criteria were trabeculectomy less than 3 months prior to AIT or follow-up under 1 year. RESULTS: Seventy-three eyes of 73 patients with 1 year follow-up were identified. At 1 year, mean IOP in AIT significantly decreased by 28% from 23.7±5.5 mm Hg, and medications from 2.8±1.2 to 2±1.3 (n=58). In phaco-AIT, the mean IOP decreased 19% from 20±5.9 mm Hg and medications from 2.5±1.5 to 1.6±1.4 (n=15). Transient hypotony occurred in 7%, and further surgery was necessary in 18%. For AIT and phaco-AIT, the 1-year cumulative probability of success was 81% and 87%, respectively. CONCLUSIONS: Both AIT and phaco-AIT showed a reduction in IOP and medication use after 1 year, suggesting that AIT with or without cataract surgery is a safe and effective option following failed trabeculectomy.


Assuntos
Glaucoma/cirurgia , Malha Trabecular/cirurgia , Trabeculectomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Reoperação , Tonometria Ocular , Falha de Tratamento , Resultado do Tratamento , Adulto Jovem
4.
Br J Ophthalmol ; 99(7): 914-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25336577

RESUMO

AIM: To analyse ab interno trabeculectomy (AIT) with the trabectome and combined phacoemulsification with AIT (phaco-AIT) by Shaffer angle grade (SG). METHODS: Prospective study of AIT and phaco-AIT with narrow angles of SG≤2 versus open angles ≥3. Outcomes included intraocular pressure (IOP), medications, complications, secondary surgery and success (IOP <21 mm Hg and >20% reduction without further surgery). Exclusion criteria were missing preoperative data and <1 year follow-up. RESULTS: Of 671 included cases, at 1 year AIT SG≤2 (n=43) had an IOP reduction of 42% from 27.3±7.4 to 15.7±3.0 mm Hg (p<0.01) versus AIT SG≥3 (n=271) with an IOP reduction of 37% from 26.1±7.8 to 16.4±3.9 mm Hg (p<0.01). In phaco-AIT with SG≤2 (n=48), IOP was reduced 24% from 20.7±7.0 to 15.7±3.6 mm Hg (p<0.01) versus phaco-AIT with SG≥3 (n=309) with an IOP reduction of 25% from 22.6±6.4 to 17.0±3.4 mm Hg (p<0.01). There was no difference between SG≤2 and SG≥3 in reduction of IOP or medications, complications, secondary surgery and success rates (p>0.05). CONCLUSIONS: SG≤2 is not associated with worse outcomes in AIT or phaco-AIT.


Assuntos
Câmara Anterior/patologia , Glaucoma/cirurgia , Facoemulsificação , Trabeculectomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/administração & dosagem , Humor Aquoso/metabolismo , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Prospectivos , Tonometria Ocular , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...