1.
PLoS One ; 8(3): e59526, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23555692

RESUMO

PURPOSE: To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. MATERIALS AND METHODS: Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. RESULTS: Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. CONCLUSION: In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections.


Assuntos
Escuridão , Enfisema Pulmonar/diagnóstico por imagem , Radiografia/métodos , Animais , Estudos de Viabilidade , Feminino , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Pulmão/fisiopatologia , Camundongos , Camundongos Endogâmicos C57BL , Enfisema Pulmonar/patologia , Enfisema Pulmonar/fisiopatologia , Testes de Função Respiratória , Espalhamento de Radiação , Sensibilidade e Especificidade , Raios X
2.
Z Med Phys ; 23(3): 236-42, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23219282

RESUMO

PURPOSE: An experimental comparison of the contrast-to-noise ratio (CNR) between transmission and dark-field signals in grating-based X-ray imaging for ex-vivo murine lung tissue. MATERIALS AND METHODS: Lungs from three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Background noise of transmission and dark-field signal was quantified by measuring the standard deviation in a region of interest (ROI) placed in a homogeneous area outside the specimen. Image contrast was quantified by measuring the signal range in rectangular ROIs placed in central and peripheral lung parenchyma. The relative contrast gain (RCG) of dark-field over transmission images was calculated as CNRDF / CNRT. RESULTS: In all images, there was a trend for contrast-to-noise ratios of dark-field images (CNRDF) to be higher than for transmission images (CNRT) for all ROIs (median 61 vs. 38, p=0.10), but the difference was statistically significant only for peripheral ROIs (61 vs. 32, p=0.03). Median RCG was >1 for all ROIs (1.84). RCG values were significantly smaller for central ROIs than for peripheral ROIs (1.34 vs. 2.43, p=0.03). CONCLUSION: The contrast-to-noise ratio of dark-field images compares more favorably to the contrast-to-noise ratio of transmission images for peripheral lung regions as compared to central regions. For any specific specimen, a calculation of the RCG allows comparing which X-ray modality (dark-field or transmission imaging) produces better contrast-to-noise characteristics in a well-defined ROI.


Assuntos
Iluminação/métodos , Pulmão/diagnóstico por imagem , Refratometria/instrumentação , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Difração de Raios X/instrumentação , Animais , Cadáver , Feminino , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Z Med Phys ; 23(3): 186-93, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23199611

RESUMO

Iterative reconstruction has a wide spectrum of proven advantages in the field of conventional X-ray absorption-based computed tomography (CT). In this paper, we report on an algebraic iterative reconstruction technique for grating-based differential phase-contrast CT (DPC-CT). Due to the differential nature of DPC-CT projections, a differential operator and a smoothing operator are added to the iterative reconstruction, compared to the one commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured at a two-grating interferometer setup. Since the algorithm is easy to implement and allows for the extension to various regularization possibilities, we expect a significant impact of the method for improving future medical and industrial DPC-CT applications.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Refratometria/métodos , Tomografia Computadorizada por Raios X/métodos , Difração de Raios X/métodos , Animais , Humanos , Imagens de Fantasmas , Refratometria/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Difração de Raios X/instrumentação
4.
J Synchrotron Radiat ; 19(Pt 4): 525-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22713884

RESUMO

The Compact Light Source is a miniature synchrotron producing X-rays at the interaction point of a counter-propagating laser pulse and electron bunch through the process of inverse Compton scattering. The small transverse size of the luminous region yields a highly coherent beam with an angular divergence of a few milliradians. The intrinsic monochromaticity and coherence of the produced X-rays can be exploited in high-sensitivity differential phase-contrast imaging with a grating-based interferometer. Here, the first multimodal X-ray imaging experiments at the Compact Light Source at a clinically compatible X-ray energy of 21 keV are reported. Dose-compatible measurements of a mammography phantom clearly demonstrate an increase in contrast attainable through differential phase and dark-field imaging over conventional attenuation-based projections.


Assuntos
Mamografia/métodos , Imagens de Fantasmas , Diagnóstico por Imagem/métodos , Síncrotrons
5.
J Synchrotron Radiat ; 16(Pt 1): 43-7, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19096173

RESUMO

The first imaging results obtained from a small-size synchrotron are reported. The newly developed Compact Light Source produces inverse Compton X-rays at the intersection point of the counter propagating laser and electron beam. The small size of the intersection point gives a highly coherent cone beam with a few milliradian angular divergence and a few percent energy spread. These specifications make the Compact Light Source ideal for a recently developed grating-based differential phase-contrast imaging method.


Assuntos
Processamento de Imagem Assistida por Computador , Lasers , Síncrotrons , Animais , Óptica e Fotônica , Psychodidae/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...