Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Optom Vis Sci ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38950144

RESUMO

SIGNIFICANCE: Contact lenses are an increasingly popular option for correcting pediatric refractive error due to increased awareness of interventions to slow myopia progression. With limited information on the safety profiles of contact lenses in children, it is important to characterize the current understanding and promote this device's safe and effective use. PURPOSE: This scoping review evaluates characteristics of the current literature that have examined the safety of contact lenses in pediatric patients. It provides future directions for systematic reviews and identifies any gaps in the current literature or areas for future research. METHODS: Literature searches in MEDLINE via PubMed, EMBASE, The Cochrane Library, trial registries, and U.S. Food and Drug Administration clinical trial documentation were performed. Included studies (i.e., experimental and quasi-experimental studies; observational studies including prospective and retrospective cohort, case-control, and analytical cross-sectional studies, and case series of 30 or more participants) reported safety and/or complications of the use of any contact lens for correcting refractive error in children (0 to 18 years). Two independent reviewers first screened the titles and abstracts, and then full-text reports for eligibility. Conflicts in eligibility were resolved by discussions with a third reviewer. Two independent reviewers extracted data, including details about the participants, context, study methods, and key findings relevant to the review question. RESULTS: This scoping review included 73 studies from 10 countries using different contact lens modalities, primarily orthokeratology and soft contact lenses, in children (6 to 18 years). The most common adverse event reported by the studies was corneal staining (60% orthokeratology, 45% soft contact lens). CONCLUSIONS: The need for uniform reporting standards for adverse events poses challenges for comprehensive data synthesis. However, this scoping review identified a sufficient number of studies for a future systematic review to quantify the risks associated with orthokeratology and soft contact lens use in children.

2.
Clin Exp Optom ; 104(1): 42-47, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32945015

RESUMO

CLINICAL RELEVANCE: While the clinical focus of performance metrics is traditionally based on visual acuity, research from the field of visual impairment has demonstrated that metrics such as reading speed and critical print size correlate much more strongly with subjective patient reported outcomes and assessed ability in real-world tasks. BACKGROUND: More recently, digital device use has increasingly replaced many paper-based tasks. Therefore, this study aimed to assess the correlation between standard acuity/contrast metrics and functional reading ability compared to real-world performance on an iPad-based reading task with astigmatic patients corrected wearing toric and mean spherical equivalent contact lenses. METHODS: Thirty-four adult participants, with -0.75 to -1.50-D of refractive astigmatism, were enrolled in a double-masked cross-over study and fitted with toric and spherical equivalent contact lenses, in random order. A digital application was developed to assess zoom, contrast modifications, the distance at which the tablet was held, blink rate, and time to complete the reading task. High and low contrast near logMAR visual acuity were measured along with reading performance (critical print size and optimal reading speed). RESULTS: The amount participants chose to increase tablet font size (zoom) was correlated with their high-contrast visual acuity with toric correction (r = 0.434, p = 0.010). With best sphere correction, zoom was associated with reading speed (r = -0.450, p = 0.008) and working distance (r = 0.522, p = 0.002). Text zoom was also associated with horizontal (toric: r = 0.898, p < 0.001; sphere: r = 0.880, p < 0.001) and vertical scrolling (toric: r = 0.857, p < 0.001; sphere: r = 0.846, p < 0.001). There was a significant negative association between the selection of text contrast and zoom (toric: r = -0.417, p = 0.0141; sphere: r = -0.385, p = 0.025). CONCLUSION: Real-world task performance allows more robust assessment of visual function than standard visual metrics alone. Digital technology offers the opportunity to better understand the impact of different vision correction options on real-world task performance.


Assuntos
Astigmatismo , Lentes Intraoculares , Adulto , Estudos Cross-Over , Humanos , Refração Ocular , Testes Visuais , Acuidade Visual
3.
Eye Contact Lens ; 47(2): 86-90, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32568927

RESUMO

OBJECTIVES: Fitting philosophies for toric orthokeratology are based on elevation or corneal astigmatism, but it is unclear which is more effective. The purpose of this analysis was to further understand corneal shape and the relationship between peripheral elevation and central astigmatism in moderate-to-high astigmats. METHODS: Corneal tomography was measured three times on the right eyes of 25 moderate-to-high refractive myopic astigmatic adults. Corneal astigmatism and elevation were calculated at 4-, 6-, and 8-mm chords. Subjects were fitted with toric orthokeratology lenses following the manufacturer's guidelines based on elevation. Twenty subjects completed 10 days of wear. A masked examiner assessed movement and centration via slitlamp videos and quantified treatment zone and decentration from tangential power difference tomography maps. Correlations between variables were assessed. RESULTS: Average corneal astigmatism was 2.20±0.70 DC and peripheral elevation was 50.88±18.92 µm and they were strongly correlated (4 mm R2=0.96, 6 mm R2=0.92, 8 mm R2=0.86, all P<0.001). Each diopter of astigmatism equated to 25 µm of elevation at an 8-mm chord. Via slitlamp, average treatment zone area was 12.73±4.62 mm2 and 13 lenses decentered. From tomography, average treatment zone area was 7.16±2.56 mm2 and 17 were decentered. Tomography treatment zone area was negatively correlated with central corneal astigmatism (R2=0.60) and elevation at an 8-mm chord (R2=0.64, both P<0.001). CONCLUSIONS: For tomography images, central corneal astigmatism was highly correlated with peripheral elevation and may be a more expedient measure for clinical use. Treatment area decreased as corneal astigmatism and elevation increased.


Assuntos
Astigmatismo , Lentes Intraoculares , Miopia , Adulto , Astigmatismo/terapia , Córnea , Topografia da Córnea , Humanos , Miopia/terapia , Refração Ocular
4.
Optom Vis Sci ; 97(7): 518-525, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32697559

RESUMO

SIGNIFICANCE: Visual demands today incorporate a significant amount of time using digital devices. Results of this randomized crossover study of spherical and toric contact lenses demonstrated that participants were able to read smaller print size more comfortably and preferred toric contact lenses when using digital devices. PURPOSE: The purpose of this study was to assess how toric contact lens correction affects subjective and objective outcomes of astigmatic patients using real-world digital devices. METHODS: Adult participants, aged between 20 and 38 years with -0.75 to -1.50 D of astigmatism were enrolled in this double-masked randomized crossover 10-day study of Alcon Dailies Aqua Comfort Plus Sphere and Toric (Alcon, Geneva, Switzerland) contact lenses. Electronic high- and low-contrast near logMAR visual acuity and contrast sensitivity were tested. Reading performance was assessed using custom iPad applications; one used a reading sentences test, whereas the other analyzed zoom, contrast, and distance with website-based articles. Participants completed the Near Activity Visual Questionnaire and stated their preferred contact lens correction. RESULTS: Thirty seven participants were screened, 35 participants were enrolled, and 34 participants completed the study. Toric lens correction improved near high- and low-contrast visual acuity by 0.5 to 1 full line (P < .0001) and allowed participants to read one line smaller text on the iPad (P = .01). Participants increased the zoom 11% (P = .004) and the contrast 4% (P = .006) more with spherical lenses while reading articles. Participants held the iPad at approximately the same distance, about 33 cm (P = .63). Eighty five percent of participants preferred the toric correction (P < .0001). Participants reported improved satisfaction with toric lens correction (P = .0002) and noticed the most benefit with tasks such as reading small print and labels/instructions. CONCLUSIONS: This study used digital devices to demonstrate realistic benefits of toric contact lens designs for astigmatic patients.


Assuntos
Astigmatismo/fisiopatologia , Astigmatismo/terapia , Computadores , Lentes de Contato Hidrofílicas , Acuidade Visual/fisiologia , Adulto , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Leitura , Refração Ocular/fisiologia , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...