Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 13(11): e0207867, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30458050

RESUMO

Automated IHC double staining using diaminobenzidine and HRP Magenta is illustrated utilizing a new acidic block with sulfuric acid to prevent cross-reactivity. Residual cross-reactivity in double staining is determined to arise from chromogenic-bound antibodies and amplification system during the first part of the double staining.


Assuntos
Peroxidase do Rábano Silvestre/metabolismo , Imuno-Histoquímica/métodos , Coloração e Rotulagem/métodos , Automação , Benzidinas/metabolismo , Compostos de Diazônio/metabolismo
2.
PLoS One ; 12(6): e0178693, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28662073

RESUMO

AIM: Expression of the base excision repair enzyme alkylpurine-DNA-N-glycosylase (APNG) has been correlated to temozolomide resistance. Our aim was to evaluate the prognostic value of APNG in a population-based cohort with 242 gliomas including 185 glioblastomas (GBMs). Cellular heterogeneity of GBMs was taken into account by excluding APNG expression in non-tumor cells from the analysis. METHODS: APNG expression was evaluated using automated image analysis and a novel quantitative immunohistochemical (IHC) assay (qIHC), where APNG protein expression was evaluated through countable dots. Non-tumor cells were excluded using an IHC/qIHC double-staining. For verification, APNG was measured by a quantitative double-immunofluorescence (IF) assay. As validation APNG mRNA expression was evaluated using independent TCGA data. RESULTS: Using qIHC, high levels of APNG were associated with better overall survival (OS) in univariate (HR = 0.50; P < 0.001) and multivariate analysis (HR = 0.53; P = 0.001). Patients with methylated MGMT promoters and high APNG expression demonstrated better OS, than patients with methylated MGMT promoters and low APNG expression (HR = 0.59; P = 0.08). Retesting the cohort using IF showed similar results in both univariate (HR = 0.61; P = 0.002) and multivariate analysis (HR = 0.81; P = 0.2). The results were supported by data from the TCGA database. CONCLUSIONS: Using two different assays combined with quantitative image analysis excluding non-tumour cells, APNG was an independent prognostic factor among patients with a methylated MGMT promoter. We expect that APNG qIHC can potentially identify GBM patients who will not benefit from treatment with temozolomide.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/patologia , DNA Glicosilases/metabolismo , Glioblastoma/patologia , Idoso , Neoplasias Encefálicas/enzimologia , DNA Glicosilases/genética , Bases de Dados Genéticas , Feminino , Glioblastoma/enzimologia , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Prognóstico , Análise de Sobrevida
3.
Mod Pathol ; 30(2): 180-193, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27767098

RESUMO

In clinical routine pathology today, detection of protein in intact formalin-fixed, paraffin-embedded tissue is limited to immunohistochemistry, which is semi-quantitative. This study presents a new and reliable quantitative immunohistochemistry method, qIHC, based on a novel amplification system that enables quantification of protein directly in formalin-fixed, paraffin-embedded tissue by counting of dots. The qIHC technology can be combined with standard immunohistochemistry, and assessed using standard bright-field microscopy or image analysis. The objective was to study analytical performance of the qIHC method. qIHC was tested under requirements for an analytical quantitative test, and compared with ELISA and flow cytometry for quantitative protein measurements. Human epidermal growth factor receptor 2 (HER2) protein expression was measured in five different cell lines with HER2 expression from undetectable with immunohistochemistry to strong positive staining (IHC 3+). Repeatability, reproducibility, robustness, linearity, dynamic range, sensitivity, and quantification limits were evaluated. Reproducibility and robustness were assessed in a setup to resemble daily work in a laboratory using a commercial immunohistochemistry platform. In addition, qIHC was correlated to standard HER2 immunohistochemistry in 44 breast cancer specimens. For all evaluated parameters, qIHC performance was either comparable or better than the reference methods. Furthermore, qIHC has a lower limit of detection than both immunohistochemistry and the ELISA reference method, and demonstrated ability to measure HER2 accurately and precise within a large dynamic range. In conclusion, the results show that qIHC provides a sensitive, quantitative, accurate, and robust assay for measurement of protein expression in formalin-fixed, paraffin-embedded cell lines, and tissue.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/diagnóstico , Imuno-Histoquímica/métodos , Receptor ErbB-2/metabolismo , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Regulação Neoplásica da Expressão Gênica , Humanos , Inclusão em Parafina , Reprodutibilidade dos Testes
4.
Bioconjug Chem ; 25(6): 1036-42, 2014 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-24852797

RESUMO

Novel reporters have been synthesized with extended hydrophilic linkers that in combination with polymerizing cross-linkers result in very efficient reporter deposition. By utilizing antibodies to stain HER2 proteins in a cell line model it is demonstrated that the method is highly specific and sensitive with virtually no background. The detection of HER2 proteins in tissue was used to visualize individual antigens as small dots visible in a microscope. Image analysis-assisted counting of fluorescent or colored dots allowed assessment of relative protein levels in tissue. Taken together, we have developed novel reporters that improve the CARD method allowing highly sensitive in situ detection of proteins in tissue. Our findings suggest that in situ protein quantification in biological samples can be performed by object recognition and enumeration of dots, rather than intensity-based fluorescent or colorimetric assays.


Assuntos
Anticorpos/metabolismo , Benzidinas/metabolismo , Reagentes de Ligações Cruzadas/metabolismo , Peroxidase do Rábano Silvestre/metabolismo , Receptor ErbB-2/análise , Anticorpos/química , Benzidinas/química , Biocatálise , Linhagem Celular Tumoral , Reagentes de Ligações Cruzadas/síntese química , Reagentes de Ligações Cruzadas/química , Peroxidase do Rábano Silvestre/química , Humanos , Estrutura Molecular , Receptor ErbB-2/biossíntese
5.
Prenat Diagn ; 23(1): 52-9, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12533814

RESUMO

OBJECTIVES: Fetal nucleated red blood cells (NRBC) that enter the peripheral blood of the mother are suitable for non-invasive prenatal diagnosis. The application of peptide nucleic acid (PNA) probes for tyramide amplified flow fluorescence in situ hybridization (FISH) detection of gamma-globin mRNA in fixed fetal NRBC is investigated. METHODS: Hemin-induced K562 cells or nucleated blood cells (NBC) from male cord blood were mixed with NBC from non-pregnant women and analysed using both slide and flow FISH protocols. Post-chorionic villus sampling (CVS) blood samples from pregnant females carrying male fetuses were flow-sorted (2 x 10(6) NBC/sample). Y chromosome-specific PNA FISH was used to confirm that the identified gamma-globin mRNA stained cells were of fetal origin. RESULTS: Flow FISH isolated gamma-globin mRNA positive NBCs showing characteristic cytoplasmic staining were all Y positive. The amplification system generated a population of false positive cells that were, however, easy to distinguish from the NRBCs in the microscope. CONCLUSION: The gamma-globin mRNA specific PNA probes can be used for detection and isolation of fetal NRBCs from maternal blood. The method has additional potential for the study of gamma-globin mRNA levels or the frequency of adult NRBC (F cells) in patients with hemoglobinopathies.


Assuntos
Eritroblastos/química , Sangue Fetal/química , Hibridização in Situ Fluorescente , Ácidos Nucleicos Peptídicos/análise , Diagnóstico Pré-Natal/métodos , RNA Mensageiro/análise , Adulto , Sequência de Bases , Cromossomos Humanos Y , Eritroblastos/citologia , Feminino , Sangue Fetal/citologia , Transfusão Feto-Materna , Citometria de Fluxo , Humanos , Imunoglobulina G/genética , Recém-Nascido , Masculino , Microscopia de Fluorescência , Dados de Sequência Molecular , Gravidez , Alinhamento de Sequência , Células Tumorais Cultivadas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...