Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ear Hear ; 35(4): 418-22, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24658601

RESUMO

OBJECTIVES: The goal of this study was to create and validate a new set of sentence lists that could be used to evaluate the speech-perception abilities of listeners with hearing loss in cases where adult materials are inappropriate due to difficulty level or content. The authors aimed to generate a large number of sentence lists with an equivalent level of difficulty for the evaluation of performance over time and across conditions. DESIGN: The original Pediatric AzBio sentence corpus included 450 sentences recorded from one female talker. All sentences included in the corpus were successfully repeated by kindergarten and first-grade students with normal hearing. The mean intelligibility of each sentence was estimated by processing each sentence through a cochlear implant simulation and calculating the mean percent correct score achieved by 15 normal-hearing listeners. After sorting sentences by mean percent correct scores, 320 sentences were assigned to 16 lists of equivalent difficulty. List equivalency was then validated by presenting all sentence lists, in a novel random order, to adults and children with hearing loss. A final-validation stage examined single-list comparisons from adult and pediatric listeners tested in research or clinical settings. RESULTS: The results of the simulation study allowed for the creation of 16 lists of 20 sentences. The average intelligibility of each list ranged from 78.4 to 78.7%. List equivalency was then validated, when the results of 16 adult cochlear implant users and 9 pediatric hearing aid and cochlear implant users revealed no significant differences across lists. The binomial distribution model was used to account for the inherent variability observed in the lists. This model was also used to generate 95% confidence intervals for one and two list comparisons. A retrospective analysis of 361 instances from 78 adult cochlear implant users and 48 instances from 36 pediatric cochlear implant users revealed that the 95% confidence intervals derived from the model captured 94% of all responses (385 of 409). CONCLUSIONS: The cochlear implant simulation was shown to be an effective method for estimating the intelligibility of individual sentences for use in the evaluation of cochlear implant users. Furthermore, the method used for constructing equivalent sentence lists and estimating the inherent variability of the materials has also been validated. Thus, the AzBio Pediatric Sentence Lists are equivalent and appropriate for the assessment of speech-understanding abilities of children with hearing loss as well as adults for whom performance on AzBio sentences is near the floor.


Assuntos
Implante Coclear , Auxiliares de Audição , Perda Auditiva Neurossensorial/cirurgia , Testes de Discriminação da Fala/métodos , Percepção da Fala , Adulto , Criança , Pré-Escolar , Feminino , Perda Auditiva Neurossensorial/reabilitação , Humanos , Masculino , Reprodutibilidade dos Testes , Inteligibilidade da Fala
2.
Ear Hear ; 33(1): 112-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21829134

RESUMO

OBJECTIVES: The goal of this study was to create and validate a new set of sentence lists that could be used to evaluate the speech perception abilities of hearing-impaired listeners and cochlear implant (CI) users. Our intention was to generate a large number of sentence lists with an equivalent level of difficulty for the evaluation of performance over time and across conditions. DESIGN: The AzBio sentence corpus includes 1000 sentences recorded from two female and two male talkers. The mean intelligibility of each sentence was estimated by processing each sentence through a five-channel CI simulation and calculating the mean percent correct score achieved by 15 normal-hearing listeners. Sentences from each talker were sorted by percent correct score, and 165 sentences were selected from each talker and were then sequentially assigned to 33 lists, each containing 20 sentences (5 sentences from each talker). List equivalency was validated by presenting all lists, in random order, to 15 CI users. RESULTS: Using sentence scores from the CI simulation study produced 33 lists of sentences with a mean score of 85% correct. The results of the validation study with CI users revealed no significant differences in percent correct scores for 29 of the 33 sentence lists. However, individual listeners demonstrated considerable variability in performance on the 29 lists. The binomial distribution model was used to account for the inherent variability observed in the lists. This model was also used to generate 95% confidence intervals for one and two list comparisons. A retrospective analysis of 172 instances where research subjects had been tested on two lists within a single condition revealed that 94% of results were accurately contained within these confidence intervals. CONCLUSIONS: The use of a five-channel CI simulation to estimate the intelligibility of individual sentences allowed for the creation of a large number of sentence lists with an equivalent level of difficulty. The results of the validation procedure with CI users found that 29 of 33 lists allowed scores that were not statistically different. However, individual listeners demonstrated considerable variability in performance across lists. This variability was accurately described by the binomial distribution model and was used to estimate the magnitude of change required to achieve statistical significance when comparing scores from one and two lists per condition. Fifteen sentence lists have been included in the AzBio Sentence Test for use in the clinical evaluation of hearing-impaired listeners and CI users. An additional eight sentence lists have been included in the Minimum Speech Test Battery to be distributed by the CI manufacturers for the evaluation of CI candidates.


Assuntos
Implante Coclear , Perda Auditiva/diagnóstico , Perda Auditiva/reabilitação , Testes de Discriminação da Fala/métodos , Testes de Discriminação da Fala/normas , Percepção da Fala , Adulto , Feminino , Humanos , Linguística , Masculino , Reprodutibilidade dos Testes , Inteligibilidade da Fala , Gravação em Fita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...