Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circulation ; 128(16): 1739-47, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23995538

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator indications in Brugada syndrome remain controversial, especially in asymptomatic patients. Previous outcome data are limited by relatively small numbers of patients or short follow-up durations. We report the outcome of patients with Brugada syndrome implanted with an implantable cardioverter-defibrillator in a large multicenter registry. METHODS AND RESULTS: A total of 378 patients (310 male; age, 46±13 years) with a type 1 Brugada ECG pattern implanted with an implantable cardioverter-defibrillator (31 for aborted sudden cardiac arrest, 181 for syncope, and 166 asymptomatic) were included. Fifteen patients (4%) were lost to follow-up. During a mean follow-up of 77±42 months, 7 patients (2%) died (1 as a result of an inappropriate shock), and 46 patients (12%) had appropriate device therapy (5±5 shocks per patient). Appropriate device therapy rates at 10 years were 48% for patients whose implantable cardioverter-defibrillator indication was aborted sudden cardiac arrest, 19% for those whose indication was syncope, and 12% for the patients who were asymptomatic at implantation. At 10 years, rates of inappropriate shock and lead failure were 37% and 29%, respectively. Inappropriate shock occurred in 91 patients (24%; 4±4 shocks per patient) because of lead failure (n=38), supraventricular tachycardia (n=20), T-wave oversensing (n=14), or sinus tachycardia (n=12). Importantly, introduction of remote monitoring, programming a high single ventricular fibrillation zone (>210-220 bpm), and a long detection time were associated with a reduced risk of inappropriate shock. CONCLUSIONS: Appropriate therapies are more prevalent in symptomatic Brugada syndrome patients but are not insignificant in asymptomatic patients (1%/y). Optimal implantable cardioverter-defibrillator programming and follow-up dramatically reduce inappropriate shock. However, lead failure remains a major problem in this population.


Assuntos
Síndrome de Brugada/mortalidade , Síndrome de Brugada/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Adulto , Idoso , Síndrome de Brugada/diagnóstico , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...