Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38730858

RESUMO

Cladding with a stick electrode is one of the oldest arc processes for adding a deposit on a base material. The process is suitable for outdoor working, but the disadvantages are low productivity and large dilution rates. In this work, a simple solution is proposed, which would enable cladding of a larger area with one pass and decrease the dilution rate at the same time-a new type of electrode was developed, exhibiting a rectangular cross-section instead of a round one. Hardfacings, welded with E Fe8 electrodes according to EN 14 700 Standard were welded on mild steel S355 J2 base material with three different coated stick electrodes. The first one was a commercially available, standard, round hardfacing electrode, the second was the same, but with a thinner coating, and the third one was a newly developed rectangular electrode. All three types had equal cross-sections of the metallic core and the same type of coating. Manufacturing of the rectangular electrodes in the laboratory is explained briefly. One- and multi-layer deposits were welded with all three types. Differences were observed in the arc behavior between the round and rectangular electrodes. With the rectangular electrode, the microstructure of the deposit was finer, penetration was shallower, and dilution rates were lower, while the hardness was higher, residual stresses predominantly compressive, and the results of instrumented Charpy impact tests and fracture mechanics tests were better.

2.
Materials (Basel) ; 15(19)2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36234121

RESUMO

Heat-affected zones (HAZs) in real welds are usually quite narrow, and consequently most standard mechanical tests are difficult or even impossible. Therefore, simulated microstructures are often used for mechanical tests. However, the most often used weld thermal cycle simulator produces only a few millimeters wide area of simulated microstructure in the middle of specimens. Consequently, these kind of simulated specimen are not suitable for standard tensile tests, and even for Charpy impact tests, the simulated area can be too narrow. Therefore, to investigate the mechanical properties of a fine-grain heat-affected zone in 18CrNiMo7-6 steel, two methods were used for simulation of as-welded microstructures: (a) a weld thermal cycle simulator, and (b) as an alternative, though not yet verified option, austenitizing in a laboratory furnace + water quenching. The microstructures were compared and mechanical properties investigated. The grain sizes of the simulated specimens were 10.9 µm (water-quenched) and 12.6 µm (simulator), whereby the deviations from the real weld were less than 10%. Both types of simulated specimen were used for hardness measurement, Charpy impact tests, and fatigue tests. Water-quenched specimens were large enough to enable standard tensile testing. A hardness of 425 HV, yield strength Rp02 = 1121 MPa, tensile strength Rm = 1475 MPa, impact energy KV = 73.11 J, and crack propagation threshold ΔKthR = 4.33 MPa m0.5 were obtained with the water quenched specimens, and 419 HV, KV = 101.49 J, and ΔKthR = 3.4 MPa m0.5 with the specimens prepared with the simulator. Comparison of the results confirmed that the annealed and quenched specimens were suitable for mechanical tests of FG HAZs, even for standard tensile tests. Due to the use of simulated test specimens, the mechanical properties determined can be linked to the FG HAZ microstructure in 18CrNiMo7-6 steel.

3.
Acta Biomater ; 6(1): 308-17, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19540942

RESUMO

Cu-Al-Ni shape memory alloys (SMAs) have been investigated as materials for medical devices, but their biomedical application is still limited. The aim of this work was to compare the microstructure, corrosion and cytotoxicity in vitro of a Cu-Al-Ni SMA. Rapidly solidified (RS) thin ribbons, manufactured via melt spinning, were used for the tests. The control alloy was a permanent mould casting of the same composition, but without shape memory effect. The results show that RS ribbons are significantly more resistant to corrosion compared with the control alloy, as judged by the lesser release of Cu and Ni into the conditioning medium. These results correlate with the finding that RS ribbons were not cytotoxic to L929 mouse fibroblasts and rat thymocytes. In addition, the RS ribbon conditioning medium inhibited cellular proliferation and IL-2 production by activated rat splenocytes to a much lesser extent. The inhibitory effects were almost completely abolished by conditioning the RS ribbons in culture medium for 4 weeks. Microstructural analysis showed that RS ribbons are martensitic, with boron particles as a minor phase. In contrast, the control Cu-Al-Ni alloy had a complex multiphase microstructure. Examination of the alloy surfaces after conditioning by energy dispersive X-ray and Auger electron spectroscopy showed the formation of Cu and Al oxide layers and confirmed that the metals in RS ribbons are less susceptible to oxidation and corrosion compared with the control alloy. In conclusion, these results suggest that rapid solidification significantly improves the corrosion stability and biocompatibility in vitro of Cu-Al-Ni SMA ribbons.


Assuntos
Ligas/química , Alumínio/química , Materiais Biocompatíveis/química , Cobre/química , Ligas Dentárias/química , Níquel/química , Animais , Apoptose , Sobrevivência Celular , Corrosão , Masculino , Camundongos , Oxigênio/química , Ratos , Baço/citologia , Propriedades de Superfície , Sais de Tetrazólio/química , Tiazóis/química , Timo/citologia
4.
J Biomater Appl ; 25(3): 269-86, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20008088

RESUMO

Cu-Al-Ni shape memory alloys (SMAs) have been investigated as materials for medical devices, but little is known about their biocompatibility. The aim of this work was to study the response of rat peritoneal macrophages (PMØ) to a Cu-Al-Ni SMA in vitro, by measuring the functional activity of mitochondria, necrosis, apoptosis, and production of proinflammatory cytokines. Rapidly solidified (RS) thin ribbons were used for the tests. The control alloy was a permanent mold casting of the same composition, but without the shape memory effect. Our results showed that the control alloy was severely cytotoxic, whereas RS ribbons induced neither necrosis nor apoptosis of PMØ. These findings correlated with the data that RS ribbons are significantly more resistant to corrosion compared to the control alloy, as judged by the lesser release of Cu and Ni in the conditioning medium. However, the ribbons generated intracellular reactive oxygen species and upregulated the production of IL-6 by PMØ. These effects were almost completely abolished by conditioning the RS ribbons for 5 weeks. In conclusion, RS significantly improves the corrosion stability and biocompatibility of Cu-Al-Ni SMA. The biocompatibility of this functional material could be additionally enhanced by conditioning the ribbons in cell culture medium.


Assuntos
Ligas/metabolismo , Alumínio/metabolismo , Materiais Biocompatíveis/metabolismo , Cobre/metabolismo , Macrófagos/citologia , Níquel/metabolismo , Ligas/química , Alumínio/química , Alumínio/imunologia , Animais , Apoptose , Materiais Biocompatíveis/química , Sobrevivência Celular , Células Cultivadas , Cobre/química , Cobre/imunologia , Citocinas/imunologia , Macrófagos/imunologia , Macrófagos/metabolismo , Masculino , Níquel/química , Níquel/imunologia , Peritônio/citologia , Ratos , Espécies Reativas de Oxigênio/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...