Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Regul Toxicol Pharmacol ; 70(3): 704-10, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25444997

RESUMO

Leading commercial electronic cigarettes were tested to determine bulk composition. The e-cigarettes and conventional cigarettes were evaluated using machine-puffing to compare nicotine delivery and relative yields of chemical constituents. The e-liquids tested were found to contain humectants, glycerin and/or propylene glycol, (⩾75% content); water (<20%); nicotine (approximately 2%); and flavor (<10%). The aerosol collected mass (ACM) of the e-cigarette samples was similar in composition to the e-liquids. Aerosol nicotine for the e-cigarette samples was 85% lower than nicotine yield for the conventional cigarettes. Analysis of the smoke from conventional cigarettes showed that the mainstream cigarette smoke delivered approximately 1500times more harmful and potentially harmful constituents (HPHCs) tested when compared to e-cigarette aerosol or to puffing room air. The deliveries of HPHCs tested for these e-cigarette products were similar to the study air blanks rather than to deliveries from conventional cigarettes; no significant contribution of cigarette smoke HPHCs from any of the compound classes tested was found for the e-cigarettes. Thus, the results of this study support previous researchers' discussion of e-cigarette products' potential for reduced exposure compared to cigarette smoke.


Assuntos
Aerossóis/análise , Sistemas Eletrônicos de Liberação de Nicotina , Substâncias Perigosas/análise , Fumaça/análise , Produtos do Tabaco , Monóxido de Carbono/análise , Glicerol/análise , Nicotina/análise , Propilenoglicol/análise
2.
Int J Environ Res Public Health ; 11(11): 11177-91, 2014 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-25350011

RESUMO

Exhaled aerosols were collected following the use of two leading U.S. commercial electronic cigarettes (e-cigarettes) and a conventional cigarette by human subjects and analyzed for phenolics, carbonyls, water, glycerin and nicotine using a vacuum-assisted filter pad capture system. Exhaled breath blanks were determined for each subject prior to each product use and aerosol collection session. Distribution and mass balance of exhaled e-cigarette aerosol composition was greater than 99.9% water and glycerin, and a small amount (<0.06%) of nicotine. Total phenolic content in exhaled e-cigarette aerosol was not distinguishable from exhaled breath blanks, while total phenolics in exhaled cigarette smoke were significantly greater than in exhaled e-cigarette aerosol and exhaled breaths, averaging 66 µg/session (range 36 to 117 µg/session). The total carbonyls in exhaled e-cigarette aerosols were also not distinguishable from exhaled breaths or room air blanks. Total carbonyls in exhaled cigarette smoke was significantly greater than in exhaled e-cigarette aerosols, exhaled breath and room air blanks, averaging 242 µg/session (range 136 to 352 µg/session). These results indicate that exhaled e-cigarette aerosol does not increase bystander exposure for phenolics and carbonyls above the levels observed in exhaled breaths of air.


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Sistemas Eletrônicos de Liberação de Nicotina , Fumaça/análise , Produtos do Tabaco/análise , Adulto , Humanos , Pessoa de Meia-Idade , Adulto Jovem
3.
Environ Sci Technol ; 36(9): 2048-53, 2002 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-12026991

RESUMO

This work involves the novel use of a radio telemetry-based system that continuously monitors phosphine using two different types of electrochemical detectors (ECD/RT). The ECD/RT units were used to monitor phosphine inside and at varying distances from large tobacco storage warehouses. A master controller unit transferred the data to a personal computer that received and displayed the data. Supervisory control and data acquisition software assimilated the data from each ECD/RT unit, displayed and updated it as new transmissions were received, and stored the data in secure databases. Phosphine concentrations outside five warehouses simultaneously under fumigation and at the facility boundaries were <0.3 parts per million (ppm). Phosphine levels ranged from 0 to 580 ppm inside sealed warehouses. A comparison was made between the data collected at an ECD/RT unit approximately 4 m downwind of a sealed warehouse and a colorimetric tube at the same location. The final phosphine concentration from the colorimetric method was 0.05 ppm and the average over the 20-minute collection period for the ECD/RT was 0.13 ppm. This system allows for continuous, remote monitoring around warehouses under fumigation and superior time resolution allowing timely response to fugitive emissions of phosphine.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Inseticidas/análise , Fosfinas/análise , Eletroquímica , Controle de Pragas , Ondas de Rádio , Software , Telemetria , Nicotiana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...