Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
iScience ; 27(3): 109250, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38439975

RESUMO

The cross-axis projection error (CAPE) caused by residual magnetic fields has recently attracted widespread attention. In this study, we propose a more specific theoretical model and expand the CAPE in gradient measurements. We first report that differences in relaxation rate and residual magnetic field between optically pumped magnetometers (OPMs) introduce a significant error term in the output of OPM gradiometers, referred to as the gradient phase error. Furthermore, when the longitudinal field compensation is inadequate, the interaxial response interference of a single OPM is prominent, resulting in an amplitude distortion of the signal. This is further amplified in the gradiometer configuration, introducing the gradient amplitude error. Our experiments demonstrated that the efficacy of mitigating common-mode noise of OPM gradiometers was significantly impaired when existing the gradient errors. In addition, a simulation with a magnetoencephalography (MEG) system illustrated an induced source localization error of exceeding 2 cm, severely compromising the localization accuracy of OPM-MEG systems.

2.
Opt Express ; 31(13): 21280-21295, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37381231

RESUMO

We propose a miniaturized single-beam optically pumped magnetometer (OPM) with a laser power differential structure, along with a dynamically-adjusted detection circuit. This design enables the suppression of optical fluctuation noise and the enhancement of magnetometer sensitivity. For a single-beam OPM, pump light fluctuation noise is a significant contributor to output noise. To address this, we propose an OPM with a laser differential structure that separates the pump light as a part of the reference signal before it enters the cell. The reference current and OPM output current are then subtracted to suppress the noise introduced by pump light fluctuations. To achieve optimal optical noise suppression, we implement balanced homodyne detection (BHD) with real-time current adjustment, which dynamically adjusts the reference ratio between the two currents according to their amplitude. Ultimately, we can reduce the noise introduced by pump light fluctuations by 47% of the original. The OPM with laser power differential achieves a sensitivity of 17.5 fT/Hz1/2, with the optical fluctuation equivalent noise at 13 fT/Hz1/2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...