1.
Life (Basel) ; 14(1)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38255728

RESUMO

I-123 is preferential over I-131 for diagnostic SPECT imaging after a thyroidectomy to determine the presence and size of residual thyroid tissue for radioiodine ablation. Scattering degrades the quality of I-123 SPECT images, primarily due to the penetration of high-energy photons into the main photopeak. The objective of this study was to quantitatively and qualitatively investigate the impact of two widely used window-based scatter correction techniques, the dual energy window (DEW) and triple energy window (TEW) techniques, in I-123 postsurgical SPECT/CT thyroid imaging using an anthropomorphic phantom with small sizes of remnants and anatomically correct surrounding structures. For this purpose, non-scatter-corrected, DEW and TEW scatter-corrected SPECT/CT acquisitions were performed for 0.5-10 mL remnants within a phantom, with 0.5-12.6 MBq administered activities within the remnants, and without and with background-to-remnant activity ratios of 5% and 10%. The decrease in photons, the noise and non-uniformity in the background region due to scatter correction were measured, as well as the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) from small remnants. The images were also visually evaluated by two experienced nuclear medicine physicians. Scatter correction decreased photons to a higher extent in larger regions than smaller regions. Larger remnants yielded higher SNR and CNR values, particularly at lower background activities. It was found from the quantitative analysis and the qualitative evaluation that TEW scatter correction performed better than DEW scatter correction, particularly at higher background activities, while no significant differences were reported at lower background activities. Scatter correction should be applied in I-123 postsurgical SPECT/CT imaging to improve the image contrast and detectability of small remnants within the background.

2.
Life (Basel) ; 13(4)2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37109490

RESUMO

Post-surgical I-123 and I-131 SPECT/CT imaging can provide information on the presence and sizes of thyroid remnants and/or metastasis for an accurate re-staging of disease to apply an individualized radioiodine therapy. The purpose of this study was to develop and validate a neck-thyroid phantom with small sizes of thyroid remnants to be utilized for the optimization of post-surgical SPECT/CT imaging. 3D printing and molding techniques were used to develop the hollow human-shaped and -sized phantom which enclosed the trachea, esophagus, cervical spine, clavicle, and multiple detachable sections with different sizes of thyroid remnant in clinically relevant positions. CT images were acquired to evaluate the morphology of the phantom and the sizes of remnants. Triple-energy window scattered and attenuation corrected SPECT images were acquired for this phantom and for a modified RS-542 commercial solid neck-thyroid phantom. The response and sensitivity of the SPECT modality for different administered I-123 and I-131 activities within the equal-size remnants of both phantoms were calculated. When we compared the phantoms, using the same radiopharmaceutical and similar activities, we found that the measured sensitivities were comparable. In all cases, the I-123 counting rate was higher than the I-131 one. This phantom with capabilities to insert different small sizes of remnants and simulate different background-to-remnants activity ratios can be utilized to evaluate postsurgical thyroid SPECT/CT imaging procedures.

3.
J Nucl Cardiol ; 24(2): 698-707, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26846369

RESUMO

BACKGROUND: A phantom assembly that simulates the respiratory motion of the heart was used to investigate artifacts and their impact on defect detection. METHODS: SPECT/CT images were acquired for phantoms with and without small and large cardiac defects during normal and deep breathing, and also at four static respiratory phases. Acquisitions were reconstructed with and without AC, and with misalignment of transmission and emission scans. A quantitative analysis was performed to assess artifacts. Two physicians reported on defect presence or absence and their results were evaluated. RESULTS: All large defects were correctly reported. Attenuation reduced uptake in the basal LV walls, increasing FN physicians' reports for small defects. Respiratory motion reduced uptake mainly in the anterior and inferior walls increasing FP and FN reports on images without and with small defects, respectively. Artifacts due to misalignment between CT and SPECT scans in normal breathing phantoms did not influence the physicians' reports. CONCLUSIONS: Attenuation and respiratory motion correction should be applied to reduce artifacts before reporting on small defects in deep breathing conditions. Artifacts due to misalignment between CT and SPECT scans do not affect defect detection in normal breathing when the LV is co-registered in SPECT and CT images prior to AC.


Assuntos
Artefatos , Cardiopatias/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/instrumentação , Imagens de Fantasmas , Mecânica Respiratória , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Imagem de Perfusão do Miocárdio/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos