Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine Deform ; 11(1): 59-69, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36083461

RESUMO

STUDY DESIGN: Assessment of different proximal instrumentation stiffness features to minimize the mechanical proximal junctional failure-related risks through computer-based biomechanical models. OBJECTIVE: To biomechanically assess variations of proximal instrumentation and loads acting on the spine and construct to minimize proximal junctional failure (PJF) risks. The use of less-stiff fixation such as hooks or tensioned bands, compared to pedicle screws, at the proximal instrumentation level are considered to allow for a gradual transition in stiffness with the adjacent levels, but the impact of such flexible fixation on the loads balance and complications such as PJF remain uncertain. METHODS: Six patients with adult spine deformity who underwent posterior spinal instrumentation were used to numerically model and simulate the surgical steps, erected posture, and flexion functional loading in patient-specific multibody analyses. Three types of upper-level fixation (pedicle screws (PS), supralaminar hooks (SH), and sublaminar bands (SB) with tensions of 50, 250, and 350 N) and rod stiffness (CoCr/6 mm, CoCr/5.5 mm, Ti/5.5 mm) were simulated. The loads acting on the spine and implants of the 90 simulated configurations were analyzed using Kruskal-Wallis statistical tests. RESULTS: Simulated high-tensioned bands decreased the sagittal moment at the adjacent level proximal to the instrumentation (1.3 Nm at 250 N; 2.5 Nm at 350 N) compared to screws alone (PS) (15.6 Nm). At one level above, the high-tensioned SB increased the sagittal moment (17.7 Nm-SB vs. 15.5 Nm-PS) and bending moment on the rods (5.4 Nm and 5.7 Nm vs. 0.6 Nm) (p < 0.05). SB with 50 N tension yielded smaller changes in load transition compared to higher tension, with moments of 8.1 Nm and 16.8 Nm one and two levels above the instrumentation. The sagittal moment at the upper implant-vertebra connection decreased with the rod stiffness (1.0 Nm for CoCr/6 mm vs. 0.7 Nm for Ti/5.5 mm; p < 0.05). CONCLUSION: Simulated sublaminar bands with lower tension produced smaller changes in the load transition across proximal junctional levels. Decreasing the rod stiffness further modified these changes, with a decrease in loads associated with bone failure, however, lower stiffness did increase the rod breakage risk. LEVEL OF EVIDENCE: N/A.


Assuntos
Vértebras Lombares , Parafusos Pediculares , Humanos , Adulto , Vértebras Lombares/cirurgia , Vértebras Torácicas/cirurgia , Simulação por Computador , Amplitude de Movimento Articular
2.
Spine Deform ; 11(1): 49-58, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36083462

RESUMO

STUDY DESIGN: Assessment of sagittal lordosis distribution on mechanical proximal junctional failure-related risks through computer-based biomechanical models. OBJECTIVE: To biomechanically assess how lordosis distribution influences radiographical and biomechanical indices related to Proximal Junctional Failure (PJF). The "optimal" patient-specific targets to restore the sagittal balance in posterior spinal fusion are still not known. Among these, the effect of the lumbar lordosis correction strategy on complications such as PJF remain uncertain. METHODS: In this computational biomechanical study, five adult spinal deformity patients who underwent posterior spinal fixation were retrospectively reviewed. Their surgery, first erect posture and flexion movement were simulated with a patient-specific multibody model. Three pedicle subtraction osteotomy (PSO) levels (L3, L4, and L5) were simulated, with consistent global lordosis for a given patient and pelvic tilt adjusted accordingly to the actual surgery. Computed loads on the anterior spine and instrumentation were analyzed and compared using Kruskal-Wallis statistical tests and Spearman correlations. RESULTS: In these models, no significant correlations were found between the lordosis distribution index (LDI), PSO level and biomechanical PJF-related indices. However, increasing the sagittal vertical axis (SVA) and thoracolumbar junction angle (TLJ) and decreasing the sacral slope (SS) increased the bending moment sustained by the rods at the proximal instrumented level (r = 0.52, 0.57, - 0.56, respectively, p < 0.05). There was a negative correlation between SS and the bending moment held by the adjacent proximal segment (r = - 0.71, p < 0.05). CONCLUSION: Based on these biomechanical simulations, there was no correlation between the lordosis distribution and PJF-associated biomechanical factors. However, increasing SS and flattening the TLJ, as postural adjustment strategies required by a more distal PSO, did decrease such PJF-related factors. Sagittal restoration and PJF risks remain multifactorial, and the use of patient-specific biomechanical models may help to better understand the complex interrelated mechanisms.


Assuntos
Cifose , Lordose , Adulto , Humanos , Lordose/diagnóstico por imagem , Lordose/cirurgia , Estudos Retrospectivos , Cifose/cirurgia , Sacro , Reoperação
3.
J Biophotonics ; 12(5): e201800336, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30604478

RESUMO

The mechanical properties of biological tissues are strongly correlated to the specific distribution of their collagen fibers. Monitoring the dynamic reorganization of the collagen network during mechanical stretching is however a technical challenge, because it requires mapping orientation of collagen fibers in a thick and deforming sample. In this work, a fast polarization-resolved second harmonic generation microscope is implemented to map collagen orientation during mechanical assays. This system is based on line-to-line switching of polarization using an electro-optical modulator and works in epi-detection geometry. After proper calibration, it successfully highlights the collagen dynamic alignment along the traction direction in ex vivo murine skin dermis. This microstructure reorganization is quantified by the entropy of the collagen orientation distribution as a function of the stretch ratio. It exhibits a linear behavior, whose slope is measured with a good accuracy. This approach can be generalized to probe a variety of dynamic processes in thick tissues.


Assuntos
Colágeno/metabolismo , Fenômenos Mecânicos , Microscopia , Pele/diagnóstico por imagem , Pele/metabolismo , Animais , Fenômenos Biomecânicos , Processamento de Imagem Assistida por Computador , Camundongos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...