1.
Am J Infect Control ; 51(5): 563-566, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35948122

RESUMO

BACKGROUND: Midline catheters are recommended over peripherally inserted central catheters as short-term vascular access device for peripherally compatible infusates. We assessed the effectiveness and safety of midline catheters. METHODS: Data from midline catheter placements from June 2016 to May 2019 at a tertiary-care Veterans Administration medical center were retrospectively collected. Patients were followed until catheter removal or death, whichever occurred first. The primary outcome was completion of intended therapy; secondary outcomes were catheter-related complications, including major (eg, catheter-related bloodstream infections [CRBSI] or venous thromboembolism [VTE]) and minor (eg, catheter occlusion, kinking, dislodgement) events. RESULTS: Of 115 midlines, 62 (53.9%) were for antibiotic infusion and 49 (32.6%) for difficult access. The median dwell time was 11 days (interquartile range, 5.5-19.5 days). Midline catheters lasted through completion of therapy in 93 patients (80.9%). Catheter-related complications occurred in 27 patients (23.5%), including catheter dislodgement in 10 patients (8.7%), catheter kinking in 8 (7.0%), and catheter occlusion in 3 (2.6%). Only 1 patient experienced a major complication, a deep venous thrombosis (0.9%). CONCLUSIONS: Midlines appear to be effective and safe for short-term vascular access in patients requiring peripherally compatible infusates. While the rate of major complications is low, minor complications that necessitate device removal are common.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Estados Unidos , Humanos , Cateterismo Venoso Central/efeitos adversos , Estudos Retrospectivos , United States Department of Veterans Affairs , Catéteres , Antibacterianos , Cateterismo Periférico/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Cateteres de Demora
2.
Am J Med ; 127(4): 319-28, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24440542

RESUMO

BACKGROUND: Growing use of peripherally inserted central catheters (PICCs) has led to recognition of the risk of PICC-associated bloodstream infection. We sought to identify rates, patterns, and patient, provider, and device characteristics associated with this adverse outcome. METHODS: A retrospective cohort of consecutive adults who underwent PICC placement from June 2009 to July 2012 was assembled. Using multivariable logistic and Cox-proportional hazards regression models, covariates specified a priori were analyzed for their association with PICC-associated bloodstream infection. Odds ratios (OR) and hazard ratios (HR) with corresponding 95% confidence intervals (CI) were used to express the association between each predictor and the outcome of interest. RESULTS: During the study period, 966 PICCs were inserted in 747 unique patients for a total of 26,887 catheter days. Indications for PICC insertion included: long-term antibiotic administration (52%, n = 503), venous access (21%, n = 201), total parenteral nutrition (16%, n = 155), and chemotherapy (11%, n = 107). On bivariate analysis, intensive care unit (ICU) status (OR 3.23; 95% CI, 1.84-5.65), mechanical ventilation (OR 4.39; 95% CI, 2.46-7.82), length of stay (hospital, OR 1.04; 95% CI, 1.02-1.06 and ICU, OR 1.03; 95% CI, 1.02-1.04), PowerPICCs (C. R. Bard, Inc., Murray Hill, NJ; OR 2.58; 95% CI, 1.41-4.73), and devices placed by interventional radiology (OR 2.57; 95% CI, 1.41-4.68) were associated with PICC-bloodstream infection. Catheter lumens were strongly associated with this event (double lumen, OR 5.21; 95% CI, 2.46-11.04, and triple lumen, OR 10.84; 95% CI, 4.38-26.82). On multivariable analysis, only hospital length of stay, ICU status, and number of PICC lumens remained significantly associated with PICC bloodstream infection. Notably, the HR for PICC lumens increased substantially, suggesting earlier time to infection among patients with multi-lumen PICCs (HR 4.08; 95% CI, 1.51-11.02 and HR 8.52; 95% CI, 2.55-28.49 for double- and triple-lumen devices, respectively). CONCLUSIONS: PICC-associated bloodstream infection is most associated with hospital length of stay, ICU status, and number of device lumens. Policy and procedural oversights targeting these factors may be necessary to reduce the risk of this adverse outcome.


Assuntos
Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/epidemiologia , Cateterismo Venoso Central/efeitos adversos , Idoso , Cateterismo Venoso Central/métodos , Cateterismo Periférico , Feminino , Humanos , Masculino , Prevalência , Prognóstico , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...