Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Vet Res ; 83(2): 171-179, 2022 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-34851855

RESUMO

OBJECTIVE: To measure changes in pulmonary perfusion during pulsed inhaled nitric oxide (PiNO) delivery in anesthetized, spontaneously breathing and mechanically ventilated ponies positioned in dorsal recumbency. ANIMALS: 6 adult ponies. PROCEDURES: Ponies were anesthetized, positioned in dorsal recumbency in a CT gantry, and allowed to breathe spontaneously. Pulmonary artery, right atrial, and facial artery catheters were placed. Analysis time points were baseline, after 30 minutes of PiNO, and 30 minutes after discontinuation of PiNO. At each time point, iodinated contrast medium was injected, and CT angiography was used to measure pulmonary perfusion. Thermodilution was used to measure cardiac output, and arterial and mixed venous blood samples were collected simultaneously and analyzed. Analyses were repeated while ponies were mechanically ventilated. RESULTS: During PiNO delivery, perfusion to aerated lung regions increased, perfusion to atelectatic lung regions decreased, arterial partial pressure of oxygen increased, and venous admixture and the alveolar-arterial difference in partial pressure of oxygen decreased. Changes in regional perfusion during PiNO delivery were more pronounced when ponies were spontaneously breathing than when they were mechanically ventilated. CLINICAL RELEVANCE: In anesthetized, dorsally recumbent ponies, PiNO delivery resulted in redistribution of pulmonary perfusion from dependent, atelectatic lung regions to nondependent aerated lung regions, leading to improvements in oxygenation. PiNO may offer a treatment option for impaired oxygenation induced by recumbency.


Assuntos
Óxido Nítrico , Respiração Artificial , Animais , Cavalos , Pulmão , Perfusão/veterinária , Respiração , Respiração Artificial/veterinária
2.
Am J Vet Res ; 83(2): 162-170, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34851854

RESUMO

OBJECTIVE: To develop a method based on CT angiography and the maximum slope model (MSM) to measure regional lung perfusion in anesthetized ponies. ANIMALS: 6 ponies. PROCEDURES: Anesthetized ponies were positioned in dorsal recumbency in the CT gantry. Contrast was injected, and the lungs were imaged while ponies were breathing spontaneously and while they were mechanically ventilated. Two observers delineated regions of interest in aerated and atelectatic lung, and perfusion in those regions was calculated with the MSM. Measurements obtained with a computerized method were compared with manual measurements, and computerized measurements were compared with previously reported measurements obtained with microspheres. RESULTS: Perfusion measurements obtained with the MSM were similar to previously reported values obtained with the microsphere method. While ponies were spontaneously breathing, mean ± SD perfusion for aerated and atelectatic lung regions were 4.0 ± 1.9 and 5.0 ± 1.2 mL/min/g of lung tissue, respectively. During mechanical ventilation, values were 4.6 ± 1.2 and 2.7 ± 0.7 mL/min/g of lung tissue at end expiration and 4.1 ± 0.5 and 2.7 ± 0.6 mL/min/g of lung tissue at peak inspiration. Intraobserver agreement was acceptable, but interobserver agreement was lower. Computerized measurements compared well with manual measurements. CLINICAL RELEVANCE: Findings showed that CT angiography and the MSM could be used to measure regional lung perfusion in dorsally recumbent anesthetized ponies. Measurements are repeatable, suggesting that the method could be used to determine efficacy of therapeutic interventions to improve ventilation-perfusion matching and for other studies for which measurement of regional lung perfusion is necessary.


Assuntos
Angiografia por Tomografia Computadorizada , Pulmão , Animais , Angiografia por Tomografia Computadorizada/veterinária , Cavalos , Pulmão/diagnóstico por imagem , Perfusão/veterinária , Respiração , Tomografia Computadorizada por Raios X/veterinária
3.
Am J Vet Res ; 75(11): 949-55, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25350084

RESUMO

OBJECTIVE: To image the spatial distribution of pulmonary blood flow by means of scintigraphy, evaluate ventilation-perfusion (VA/Q) matching and pulmonary blood shunting (Qs/Qt) by means of the multiple inert gas elimination technique (MIGET), and measure arterial oxygenation and plasma endothelin-1 concentrations before, during, and after pulse-delivered inhaled nitric oxide (PiNO) administration to isoflurane-anesthetized horses in dorsal recumbency. ANIMALS: 3 healthy adult Standardbreds. PROCEDURES: Nitric oxide was pulsed into the inspired gases in dorsally recumbent isoflurane-anesthetized horses. Assessment of VA/Q matching, Qs/Qt, and Pao2 content was performed by use of the MIGET, and spatial distribution of pulmonary blood flow was measured by perfusion scintigraphy following IV injection of technetium Tc 99m-labeled macroaggregated human albumin before, during, and 30 minutes after cessation of PiNO administration. RESULTS: During PiNO administration, significant redistribution of blood flow from the dependent regions to the nondependent regions of the lungs was found and was reflected by improvements in VA/Q matching, decreases in Qs/Qt, and increases in Pao2 content, all of which reverted to baseline values at 30 minutes after PiNO administration. CONCLUSIONS AND CLINICAL RELEVANCE: Administration of PiNO in anesthetized dorsally recumbent horses resulted in redistribution of pulmonary blood flow from dependent atelectatic lung regions to nondependent aerated lung regions. Because hypoxemia is commonly the result of atelectasis in anesthetized dorsally recumbent horses, the addition of nitric oxide to inhaled gases could be used clinically to alleviate hypoxemia in horses during anesthesia.


Assuntos
Anestésicos Inalatórios , Cavalos/fisiologia , Hipóxia/veterinária , Isoflurano , Pulmão/irrigação sanguínea , Óxido Nítrico/administração & dosagem , Administração por Inalação , Adulto , Anestésicos Inalatórios/farmacologia , Animais , Artérias/efeitos dos fármacos , Gasometria/veterinária , Feminino , Frequência Cardíaca/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Hipóxia/etiologia , Hipóxia/terapia , Isoflurano/farmacologia , Pulmão/diagnóstico por imagem , Masculino , Perfusão/veterinária , Atelectasia Pulmonar/fisiopatologia , Atelectasia Pulmonar/veterinária , Cintilografia , Respiração/efeitos dos fármacos
4.
J Am Vet Med Assoc ; 235(9): 1058-63, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19878003

RESUMO

OBJECTIVE: To evaluate radiographic distribution of pulmonary edema (PE) in dogs with mitral regurgitation (MR) and investigate the association between location of radiographic findings and direction of the mitral regurgitant jet (MRJ). DESIGN: Retrospective case series. ANIMALS: 61 dogs with cardiogenic PE and MR resulting from mitral valve disease (MVD; 51 dogs), dilated cardiomyopathy (9), and hypertrophic cardiomyopathy (1). PROCEDURES: Thoracic radiographs of dogs with Doppler echocardiographic evidence of MR were reviewed for location (diffuse, perihilar, or focal) of PE. Also, direction (central or eccentric) of the MRJ, as evaluated by Doppler color flow mapping (DCFM), and distribution (symmetric or asymmetric) of radiographic findings were evaluated. RESULTS: Diffuse, perihilar, and focal increases in pulmonary opacity were observed in 11 (18.0%), 7 (11.5%), and 43 (70.5%) of 61 dogs, respectively. Radiographic evidence of asymmetric PE in a single lung lobe or 2 ipsilateral lobes was found in 21 dogs, with involvement of only the right caudal lung lobe in 17 dogs. Doppler color flow mapping of the MRJ was available for 46 dogs. Of 31 dogs with a central MRJ, 28 had radiographic findings indicative of symmetric PE. Of 15 dogs with eccentric MRJ, 11 had radiographic evidence of asymmetric PE, and all of these dogs had MVD. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs with cardiogenic PE, a symmetric radiographic distribution of increased pulmonary opacity was predominantly associated with a central MRJ, whereas an asymmetric radiographic distribution was usually associated with eccentric MRJ, especially in dogs with MVD.


Assuntos
Doenças do Cão/diagnóstico por imagem , Insuficiência da Valva Mitral/veterinária , Edema Pulmonar/veterinária , Animais , Doenças do Cão/patologia , Cães , Feminino , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/patologia , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/patologia , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...