Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Imaging ; 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37732694

RESUMO

PURPOSE: Intravenous contrast poses challenges to computed tomography (CT) muscle density analysis. We developed and tested corrections for contrast-enhanced CT muscle density to improve muscle analysis and the utility of CT scans for the assessment of myosteatosis. MATERIALS AND METHODS: Using retrospective images from 240 adults who received routine abdominal CT imaging from March to November 2020 with weight-based iodine contrast, we obtained paraspinal muscle density measurements from noncontrast (NC), arterial, and venous-phase images. We used a calibration sample to develop 9 different mean and regression-based corrections for the effect of contrast. We applied the corrections in a validation sample and conducted equivalence testing. RESULTS: We evaluated 140 patients (mean age 52.0 y [SD: 18.3]; 60% female) in the calibration sample and 100 patients (mean age 54.8 y [SD: 18.9]; 60% female) in the validation sample. Contrast-enhanced muscle density was higher than NC by 8.6 HU (SD: 6.2) for the arterial phase (female, 10.4 HU [SD: 5.7]; male, 6.0 HU [SD:6.0]) and by 6.4 HU [SD:8.1] for the venous phase (female, 8.0 HU [SD: 8.6]; male, 4.0 HU [SD: 6.6]). Corrected contrast-enhanced and NC muscle density was equivalent within 3 HU for all correctionns. The -7.5 HU correction, independent of sex and phase, performed well for arterial (95% CI: -0.18, 1.80 HU) and venous-phase data (95% CI: -0.88, 1.41 HU). CONCLUSIONS: Our validated correction factor of -7.5 HU renders contrast-enhanced muscle density statistically similar to NC density and is a feasible rule-of-thumb for clinicians to implement.

3.
Front Rehabil Sci ; 3: 896114, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36189019

RESUMO

Purpose: Establish bedside biomarkers of myosteatosis for sarcopenia and cachexia. We compared ultrasound biomarkers against MRI-based percent fat, histology, and CT-based muscle density among healthy adults and adults undergoing treatment for lung cancer. Methods: We compared ultrasound and MRI myosteatosis measures among young healthy, older healthy, and older adults with non-small cell lung cancer undergoing systemic treatment, all without significant medical concerns, in a cross-sectional pilot study. We assessed each participant's rectus femoris ultrasound-based echo intensity (EI), shear wave elastography-based shear wave speed, and MRI-based proton density fat-fraction (PDFF). We also assessed BMI, rectus femoris thickness and cross-sectional area. Rectus femoris biopsies were taken for all older adults (n = 20) and we analyzed chest CT scans for older adults undergoing treatment (n = 10). We determined associations between muscle assessments and BMI, and compared these assessments between groups. Results: A total of 10 young healthy adults, 10 older healthy adults, and 10 older adults undergoing treatment were recruited. PDFF was lower in young adults than in older healthy adults and older adults undergoing treatment (0.3 vs. 2.8 vs. 2.9%, respectively, p = 0.01). Young adults had significantly lower EI than older healthy adults, but not older adults undergoing treatment (48.6 vs. 81.8 vs. 75.4, p = 0.02). When comparing associations between measures, PDFF was strongly associated with EI (ρ = 0.75, p < 0.01) and moderately negatively associated with shear wave speed (ρ = -0.49, p < 0.01) but not BMI, whole leg cross-sectional area, or rectus femoris cross-sectional area. Among participants with CT scans, paraspinal muscle density was significantly associated with PDFF (ρ = -0.70, p = 0.023). Histological markers of inflammation or degradation did not differ between older adult groups. Conclusion: PDFF was sensitive to myosteatosis between young adults and both older adult groups. EI was less sensitive to myosteatosis between groups, yet EI was strongly associated with PDFF unlike BMI, which is typically used in cachexia diagnosis. Our results suggest that ultrasound measures may serve to determine myosteatosis at the bedside and are more useful diagnostically than traditional weight assessments like BMI. These results show promise of using EI, shear wave speed, and PDFF proxies of myosteatosis as diagnostic and therapeutic biomarkers of sarcopenia and cachexia.

4.
J Cachexia Sarcopenia Muscle ; 13(6): 2807-2819, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36065509

RESUMO

Computed tomography (CT) is a valuable assessment method for muscle pathologies such as sarcopenia, cachexia, and myosteatosis. However, several key underappreciated scan imaging parameters need consideration for both research and clinical use, specifically CT kilovoltage and the use of contrast material. We conducted a scoping review to assess these effects on CT muscle measures. We reviewed articles from PubMed, Scopus, and Web of Science from 1970 to 2020 on the effect of intravenous contrast material and variation in CT kilovoltage on muscle mass and density. We identified 971 articles on contrast and 277 articles on kilovoltage. The number of articles that met inclusion criteria for contrast and kilovoltage was 11 and 7, respectively. Ten studies evaluated the effect of contrast on muscle density of which nine found that contrast significantly increases CT muscle density (arterial phase 6-23% increase, venous phase 19-57% increase, and delayed phase 23-43% increase). Seven out of 10 studies evaluating the effect of contrast on muscle area found significant increases in area due to contrast (≤2.58%). Six studies evaluating kilovoltage on muscle density found that lower kilovoltage resulted in a higher muscle density (14-40% increase). One study reported a significant decrease in muscle area when reducing kilovoltage (2.9%). The use of contrast and kilovoltage variations can have dramatic effects on skeletal muscle analysis and should be considered and reported in CT muscle analysis research. These significant factors in CT skeletal muscle analysis can alter clinical and research outcomes and are therefore a barrier to clinical application unless better appreciated.


Assuntos
Meios de Contraste , Sarcopenia , Humanos , Sarcopenia/diagnóstico por imagem , Sarcopenia/patologia , Tomografia Computadorizada por Raios X/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Caquexia/patologia
5.
J Alzheimers Dis ; 48(3): 591-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26402075

RESUMO

Thirty-four individuals with mild cognitive impairment were randomized for 6 months to a nutraceutical formulation (NF: folate, alpha-tocopherol, B12, S-adenosyl methioinine, N-acetyl cysteine, acetyl-L-carnitine) or indistinguishable placebo, followed by a 6-month open-label extension in which all individuals received NF. The NF cohort improved in the Dementia Rating Scale (DRS; effect size >0.7) and maintained baseline performance in CLOX-1. The placebo cohort did not improve in DRS and declined in CLOX-1, but during the open-label extension improved in DRS and ceased declining in CLOX-1. These findings extend prior studies of NF efficacy for individuals without cognitive impairment and with Alzheimer's disease.


Assuntos
Disfunção Cognitiva/dietoterapia , Suplementos Nutricionais , Idoso , Estudos de Coortes , Seguimentos , Humanos , Pessoa de Meia-Idade , Escalas de Graduação Psiquiátrica , Resultado do Tratamento
6.
Int J Alzheimers Dis ; 2012: 829743, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22577593

RESUMO

Individuals with MCI declined in performance over 6 months in the Clock-drawing (Clox 1) and the WAIS Digit Span tests, but not in the Dementia Rating Scale (DRS). Individual performance on Clox 1 and Digit Span did not correlate after 6 months. Performance on the Digit Span Test also did not correlate with the DRS, but performance on Clox 1 correlated with the DRS. Performance in Clox 1 was, therefore, not a predictor of performance in the Digit Span Test. These findings support the use of a test battery containing the Digit Span test to detect and track cognitive decline in MCI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...