Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anticancer Res ; 43(1): 405-408, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36585214

RESUMO

BACKGROUND/AIM: Cone-beam computed tomography (CBCT) is the most commonly used system in modern radiotherapy of prostate cancer for daily positioning verification. The use of intraprostatic radiopaque fiducials (FMs) may be added to CBCT. We wanted to investigate the possible advantage of using FMs in daily CBCT repositioning. MATERIALS AND METHODS: We selected three CBCTs for each treatment course for 13 patients (seven with and six without use of FMs) treated at our centre. Seven experienced Radiation Oncologists retrospectively reviewed the CBCTs, recording couch movements for correct patient positioning, and time spent to do it. Analysis of variance and t-test were carried out for comparison of different groups and for differences in mean values of the movements recorded (with p<0.05 as significance level). RESULTS: No statistically significant difference was found between operators in the analysis of images with FMs nor of images without them. A difference was only found in the mean corrections in couch rotation and pitch angle, which were higher in the FM group, and in the mean time for image analysis, which was shorter in this group. Using the van Herk formula, we found a possible reduction of clinical target volume and planning target volume margins for the FM group. CONCLUSION: According to our study, the use of intraprostatic FMs in daily CBCT seems useful for better detection of and correction for non-negligible rotational errors. Furthermore, FMs reduced the time to treatment start, which is very important in reducing the risk of intrafraction organ motion. These results need to be confirmed by further studies.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Masculino , Humanos , Próstata/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos , Estudos Retrospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Marcadores Fiduciais , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
2.
J Appl Clin Med Phys ; 19(5): 517-524, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30009564

RESUMO

Octavius® -4D is a very effective device in radiotherapy treatment quality assurance (QA), due to its simple set-up and analysis package. However, even if it is widely used, its main characteristics and criticalities were only partially investigated. Taking start from its commissioning, the aim of this work was to study the main dependencies of the device response. The outcome dependence was studied comparing results by different delivery techniques [Intensity Modulated Radiation Therapy, IMRT (n = 29) and RapidArc, RA (n = 15)], anatomical regions [15 head/neck, 19 pelvis and 10 pancreas] and linear accelerators [DHX (n = 14) and Trilogy (n = 30)]. Moreover, the agreement dependency on the section of the phantom was assessed. Plan evaluations obtained by 2D, 3D, and volumetric γ-index (both local and global) were also compared. Generally, high dose gradient resulted critically managed by the assembly, with a smoother effect in RA technique. Worse agreements emerged in the 2D γ-index vs those of 3D and volumetric (P < 0.001), that were instead statistically comparable in global metric (P > 0.300). Volumetric plan evaluation was coherent with the average of passing rates on the 3 phantom axes (r ≥ 0.9), but transversal section provided best agreements vs sagittal and coronal ones (P < 0.050). The three studied districts furnished comparable results (P > 0.050) while the two LINACs provided different agreements (P < 0.005). The study pointed out that the phantom transversal section better fits the planned dose distribution, so this should be accounted when a two-dimensional evaluation is needed. Moreover, the major reliability of the 3D metric with respect to the 2D one, as it better agrees with the dosimetric evaluation on the whole volume, suggests that it should be preferred in a two-dimensional evaluation. Better agreements, obtained with RA vs IMRT technique, confirm that Octavius® -4D is specifically conceived for rotational delivery. Lastly, the assembly resulted sensitive to different technology.


Assuntos
Radioterapia de Intensidade Modulada , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...