1.
Clin Biochem ; 51: 10-20, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29061378

RESUMO

Protein electrophoresis is commonly used as an aid in the diagnosis of monoclonal gammopathies and is performed in many laboratories in Canada and throughout the world. However, unlike many other diagnostic tests, there is limited guidance for standardization and neither guidance nor specific recommendations for clinical reporting of serum (SPE) or urine (UPE) protein electrophoresis and immunotyping available in the literature. Therefore, a Canadian effort was undertaken to recommend standards that cover all aspects of clinical reporting with an ultimate goal towards reporting standardization. The Canadian Society of Clinical Chemists (CSCC) Monoclonal Gammopathy Interest Group (MGIG), which is composed of CSCC members with an interest in protein electrophoresis, has formed a Monoclonal Gammopathy Working Group (MGWG) to take initial steps towards standardization of SPE, UPE and immunotyping. Candidate standardization recommendations were developed, discussed and voted upon by the MGWG. Candidate recommendations that achieved 90% agreement are presented as consensus recommendations. Recommendations that did not achieve 90% consensus remain candidate recommendations and are presented with accompanying MGWG discussion. Eleven consensus recommendations along with candidate recommendations for nomenclature, protein fraction reporting, test utilization, interference handling and interpretive reporting options are presented.


Assuntos
Eletroforese das Proteínas Sanguíneas/métodos , Guias como Assunto , Paraproteinemias/sangue , Sociedades Médicas , Canadá , Humanos
2.
Clin Biochem ; 50(15): 864-869, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28457964

RESUMO

BACKGROUND: Core laboratory (CL), as a new business model, facilitates consolidation and integration of laboratory services to enhance efficiency and reduce costs. This study evaluates the impact of total laboratory automation system (TLA), electric track vehicle (ETV) system and auto-verification (AV) of results on overall turnaround time (TAT) (phlebotomy to reporting TAT: PR-TAT) within a CL setting. METHODS: Mean, median and percentage of outlier (OP) for PR-TAT were compared for pre- and post-CL eras using five representative tests based on different request priorities. Comparison studies were also carried out on the intra-laboratory TAT (in-lab to reporting TAT: IR-TAT) and the delivery TAT (phlebotomy to in-lab TAT: PI-TAT) to reflect the efficiency of the TLA (both before and after introducing result AV) and ETV systems respectively. RESULTS: Median PR-TATs for the urgent samples were reduced on average by 16% across all representative analytes. Median PR-TATs for the routine samples were curtailed by 51%, 50%, 49%, 34% and 22% for urea, potassium, thyroid stimulating hormone (TSH), complete blood count (CBC) and prothrombin time (PT) respectively. The shorter PR-TAT was attributed to a significant reduction of IR-TAT through the TLA. However, the median PI-TAT was delayed when the ETV was used. Application of various AV rules shortened the median IR-TATs for potassium and urea. However, the OP of PR-TAT for the STAT requests exceeding 60min were all higher than those from the pre-CL era. CONCLUSIONS: TLA and auto-verification rules help to efficiently manage substantial volumes of urgent and routine samples. However, the ETV application as it stands shows a negative impact on the PR-TAT.


Assuntos
Automação Laboratorial/métodos , Automação Laboratorial/normas , Registros Eletrônicos de Saúde/normas , Laboratórios Hospitalares/normas , Registros Eletrônicos de Saúde/instrumentação , Registros Eletrônicos de Saúde/organização & administração , Humanos , Laboratórios Hospitalares/organização & administração , Flebotomia/métodos , Flebotomia/normas , Fatores de Tempo
3.
Clin Biochem ; 49(16-17): 1254-1258, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27598438

RESUMO

BACKGROUND: Growing financial and workload pressures on laboratories coupled with user demands for faster turnaround time (TAT) has steered the implementation of total laboratory automation (TLA). The current study evaluates the impact of a complex TLA on core laboratory efficiency through the analysis of the In-lab to Report TAT (IR-TAT) for five representative tests based on the different requested priorities. METHODS: Mean, median and outlier percentages (OP) for IR-TAT were determined following TLA implementation and where possible, compared to the pre-TLA era. RESULTS: The shortest mean IR-TAT via the priority lanes of the TLA was 22min for Complete Blood Count (CBC), followed by 34min, 39min and 40min for Prothrombin time (PT), urea and potassium testing respectively. The mean IR-TAT for STAT CBC loaded directly on to the analyzers was 5min shorter than that processed via the TLA. The mean IR-TATs for both STAT potassium and urea via offline centrifugation were comparable to that processed by the TLA. The longest mean IR-TAT via regular lanes of the TLA was 62min for Thyroid-Stimulating Hormone (TSH) while the shortest was 17min for CBC. All parameters for IR-TAT for CBC and PT tests decreased significantly post- TLA across all requested priorities in particular the outlier percentage (OP) at 30 and 60min. CONCLUSIONS: TLA helps to efficiently manage substantial volumes of samples across all requested priorities. Manual processing for small STAT volumes, at both the initial centrifugation stage and front loading directly on to analyzers, is however likely to yield the shortest IR-TAT.


Assuntos
Automação Laboratorial , Humanos , Estudos de Tempo e Movimento