Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 32(7): 1442-4, 1991 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2066804

RESUMO

Results are presented for SPECT computations of liver volumes and 111In-labeled antibody activities in the livers of eight normal beagle dogs. Administered activities ranged from 1 to 2 mCi. SPECT studies were acquired 1 day postinjection using a rotating gamma camera system with elliptical orbits in a 360-degree rotation (128 views, 15 sec/view, 64 x 64 matrices). Uniformity-corrected images were reconstructed by use of the circular harmonic transform algorithm with computer software developed in-house. Liver volumes and activities were computed from transverse slices, 1 pixel (6.25 mm) in thickness. Comparison of SPECT and autopsy data demonstrated that absolute values of percent differences between measured and computed liver volumes ranged from 1.0% to 7.2%. Absolute values of percent differences between autopsy data and computed 111In activities in the liver ranged from 2.3% to 7.5%. These results suggest that quantitative SPECT has the potential of becoming an important tool in clinical trials for determining activities and localization volumes of radiolabeled antibodies directly from radionuclide images.


Assuntos
Anticorpos , Radioisótopos de Índio , Fígado/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Cães
2.
J Clin Oncol ; 9(6): 918-28, 1991 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2033428

RESUMO

Radiolabeled antiferritin immunoglobulin (Ig) preparations were tested in patients with advanced, end-stage Hodgkin's disease. Four patients received indium-111 (111In)-labeled monoclonal antiferritin (QCI). Targeting was not observed in tumor-bearing areas. Instead, scans showed rapid accumulation of QCI in normal liver. Forty-five patients were injected with 111In-labeled polyclonal antiferritin (rabbit, pig, or baboon). Forty (89%) patients showed tumor uptake, with dosimetric estimates ranging from 300 to 3,000 cGy in 1 week for the subsequently administered yttrium-90 (90Y)-labeled antiferritin. Yttrium-labeled antibody caused hematologic toxicity. Treatment-induced toxicity was not observed in any other organ system. Intravenous autologous bone marrow cells, 18 days after the yttrium infusion, accelerated hematopoietic recovery in eight patients receiving 30 mCi or 40 mCi. Hematopoietic recovery after a 20 mCi 90Y-labeled antiferritin infusion was not influenced by an autologous bone marrow transplant. Two patients receiving 20 mCi and one patient receiving 50 mCi remained aplastic after transplantation for unknown reasons. In 29 assessable patients, a 62% response rate was observed; nine of the 18 responses were complete. Responses ranging from 2 to 26 months were more commonly noted in patients with small tumors and long disease histories. Dosimetric calculations did not predict for responses. Recurrences frequently occurred in new areas instead of areas exhibiting bulky disease at the start of the treatment. Complete responses after 90Y antiferritin were significantly (P less than .02) more frequent than in a previous study with iodine-131 (131I) antiferritin. Further improvements are needed to make this new treatment modality curative.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Ferritinas/imunologia , Doença de Hodgkin/radioterapia , Radioisótopos de Ítrio/uso terapêutico , Adolescente , Adulto , Anticorpos Monoclonais/efeitos adversos , Terapia Combinada , Avaliação de Medicamentos , Feminino , Ferritinas/sangue , Seguimentos , Doenças Hematológicas/etiologia , Doença de Hodgkin/mortalidade , Humanos , Radioisótopos de Índio/efeitos adversos , Radioisótopos de Índio/uso terapêutico , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Taxa de Sobrevida , Radioisótopos de Ítrio/efeitos adversos
3.
Int J Radiat Oncol Biol Phys ; 14(5): 1033-42, 1988 May.
Artigo em Inglês | MEDLINE | ID: mdl-2834309

RESUMO

Radiation absorbed-dose estimates and treatment planning are reported for 11 patients with hepatoma who were administered 90Y-labeled polyclonal antiferritin IgG for therapy in a Phase 1-2 trial. Dosimetric studies included quantitation of the localization and clearance of 111In-labeled antiferritin IgG in tumor and normal tissues and computer-assisted tumor and normal liver volumetrics from X ray CT scans. For the group of patients studied, hepatoma volumes at the time of treatment ranged from 135 to 3442 cm3. Quantitative 111In antiferritin imaging prior to and following 600 or 900 cGy of external-beam irradiation of the primary tumor demonstrated that tumor uptake increased 1.1 to 5.8-fold (mean 2.8) following external beam. In contrast, changes in uptake of radiolabeled antiferritin in normal liver ranged from 0.35 to 2.1-fold (mean 0.93) after external irradiation. Administered activities of 90Y antiferritin ranged from 8 to 37 mCi and were dependent on tumor volume and tumor localization of radiolabeled antiferritin. Following external-beam irradiation, tumor dose rates achieved with 90Y antiferritin ranged from 10 to 20 cGy/hr and normal liver dose rates from 1.1 to 5.7 cGy/h. The corresponding absorbed dose in hepatomas ranged from 900 to 2150 cGy and in normal liver from 80 to 650 cGy. After external-beam irradiation, tumor and normal liver uptake of 90Y antiferritin was consistent with that of 131I antiferritin.


Assuntos
Anticorpos/uso terapêutico , Carcinoma Hepatocelular/radioterapia , Ferritinas/imunologia , Neoplasias Hepáticas/radioterapia , Radioisótopos de Ítrio/uso terapêutico , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
4.
J Comput Assist Tomogr ; 10(4): 621-8, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3016045

RESUMO

A new computer algorithm is described for liver and tumor volume determinations for patients with hepatoma and primary hepatic cholangiocarcinoma. The algorithm is based on global histograms of CT numbers of the liver and primary liver cancers. The algorithm includes computer-assisted definition of the liver boundary in each CT slice. Liver and tumor volumes of 10 patients calculated by the histogram method were compared with volumes obtained from CT slices that were manually contoured by experienced observers. A correlation coefficient of 0.995 was determined for these two methods of volume computations. Mean values of the differences in volumes obtained by the two methods were 6.7 and 8.0% for the liver and tumor, respectively. The computer algorithm was tested on CT scans for an additional 46 patients by highlighting regions corresponding to normal liver and tumor tissues in each CT slice and determined to be accurate by experienced observers. The computer software is being used clinically to assess tumor response in a new treatment program for primary liver cancers that includes radiolabeled antibodies.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adenoma de Ducto Biliar/diagnóstico por imagem , Adenoma de Ducto Biliar/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...