Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Case Rep ; 4: 363, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21078164

RESUMO

INTRODUCTION: We report the case of an unusual combination of concomitant subcapital and intertrochanteric fractures of the hip in a patient after a motorcycle accident. To the best of our knowledge, there is no previous report in the literature of these conditions as a result of high energy trauma or of the treatment used. CASE PRESENTATION: A 36-year-old Caucasian man was admitted with this rare fracture combination, and was managed with closed fracture reduction and fixation with a dynamic hip screw combined with an anti-rotational cannulated screw. We found four similar cases on reviewing the literature from 1989 to 2009, but these were reports of older patients after low energy injury. CONCLUSION: We found that segmental fracture of the femoral neck region is an extremely rare and uncategorized hip injury that can occur not only in older people but also in young non-osteoporotic patients, and should be considered for inclusion in femoral fracture classification systems.

2.
Injury ; 39(10): 1210-5, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18703184

RESUMO

Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Proteção Radiológica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fluoroscopia , Humanos , Cuidados Intraoperatórios/métodos , Pessoa de Meia-Idade , Exposição Ocupacional/prevenção & controle , Estudos Prospectivos , Doses de Radiação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...