Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Cardiol ; 44(7): 1514-1519, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37351603

RESUMO

Fetal echocardiograms (F-echo) are recommended in all pregnancies when the fetus has Down syndrome (DS) even if there was a prior obstetric scan (OB-scan) that was normal. The utility of a screening F-echo in this high-risk population when an OB-scan is normal is unknown. Goal of this study was to evaluate if any diagnosis of a critical congenital heart disease (CHD) was missed in a fetus with DS who had a normal OB-scan. Secondary goal was to determine if any CHD was missed postnatally when an OB-scan was read as normal. Retrospective chart review of all fetuses that had a F-echo whose indication was DS between 1/1/2010 to 6/30/2022 was performed. Fetuses were included if they had an OB-scan that was read as normal and had a F-echo. Postnatal transthoracic echocardiogram (pTTE) was reviewed when available. Critical CHD was defined as CHD requiring catheterization or surgical intervention < 1 month of age. One hundred twenty-two F-echo on fetuses with DS were evaluated, of which 48 met inclusion criteria. OB-scan was performed at 20.4 ± 4.5 weeks gestational age and F-echo was performed at 24.0 ± 4.6 weeks gestational age. No patient with a normal OB-scan had a diagnosis of a critical CHD by F-echo (n = 48, negative predictive value = 100%). Evaluating those patients that had an OB-scan and a pTTE (n = 38), 14 patients were diagnosed with CHD (muscular ventricular septal defect (VSD) n = 5, perimembraneous VSD n = 3, secundum atrial septal defect (ASD) n = 2, primum ASD n = 1, transitional atrioventricular septal defect (AVSD) n = 2, and aortic valve abnormality n = 1; negative predictive value = 63.2%). F-echo correctly diagnosed 4 of the 14 missed OB-scan CHD (perimembraneous VSD n = 2, muscular VSD n = 1, and transitional AVSD n = 1). Critical CHD was not missed with a normal OB-scan in this high-risk population. F-echo also missed the majority of CHD when an OB-scan was read as normal. The cost/benefit of screening F-echo in fetuses with DS should be evaluated if a normal OB-scan has been performed, considering all these patients would have a pTTE performed per guidelines.


Assuntos
Síndrome de Down , Cardiopatias Congênitas , Gravidez , Feminino , Humanos , Síndrome de Down/complicações , Estudos Retrospectivos , Ultrassonografia Pré-Natal , Feto , Cardiopatias Congênitas/complicações
2.
Cardiol Ther ; 11(4): 523-530, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36074260

RESUMO

INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure during infancy. METHODS: Chart review was performed on patients who had a PDA closure at not more than 1 year of age between January 1, 2002 and June 1, 2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE at least 3 months after procedure, or had a velocity greater than 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE at least 3 months after device placement. Time points included the first TTE after the procedure, first TTE at least 3 months after procedure, and the most recent TTE. RESULTS: Total of 147 infants met the inclusion criteria. Age and weight at initial procedure were 141 ± 217 days and 4.2 ± 2.8 kg. There was no significant difference in DAo velocity between initial and most recent TTE. LPA velocity and left ventricular diastolic Z score significantly decreased between initial and most recent TTE. Seventy-eight patients had repeat echocardiograms more than 1 year after PDA procedure with no change in clinical management. No patient underwent an intervention on the LPA or DAo for stenosis. CONCLUSION: In patients who underwent an uncomplicated PDA closure during infancy, TTE parameters either stayed stable or improved over time. These findings need to be corroborated in larger studies with longer follow-up. If verified, the long-term TTE guidelines may need to be simplified for this patient population.

3.
Cardiol Ther ; 11(3): 445-452, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35780440

RESUMO

INTRODUCTION: Guidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy. METHODS: Chart review was performed on patients who had a PDA closure ≥ 1 year of age between 1/1/2002 and 6/1/2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE ≥ 6 months after procedure, had a residual PDA or velocity > 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE ≥ 6 months after device placement. Time points included the initial TTE after the procedure, first TTE ≥ 6 months after procedure, and the most recent TTE. RESULTS: A total of 189 patients met the study criteria. The median age and weight at initial procedure were 2.7 (1.0-64.7) years and 12.5 (3.4-69.2) kg. Most recent TTE was performed 2.0 (0.4-17.0) years after PDA closure. There were no significant differences in fractional shortening (36.4 ± 5.0% vs. 36.9 ± 5.6%) or LPA velocity (1.1 ± 0.4 m/s vs. 1.1 ± 0.4 m/s) from initial to most recent TTE, respectively. Left ventricular internal diastolic diameter Z-score significantly decreased (1.4 ± 1.8 vs. - 0.01 ± 1.2, p < 0.01) and DAo peak velocity significantly increased (1.2 ± 0.3 m/s vs. 1.3 ± 0.3 m/s, p = 0.02) from initial to most recent TTE, respectively. No patient died or underwent an intervention on the LPA or DAo for stenosis. Seventy-five patients had a total of 208 repeat TTE > 1 year after PDA procedure with no change in clinical management. CONCLUSIONS: In patients who underwent an uncomplicated PDA closure after infancy, TTE parameters improved or stayed within normal limits on the most recent TTE. Repeat lifetime TTEs after 1-year post-device placement in this population may not necessarily be needed if there are no clinical concerns.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...