Med Phys ; 50(1): 619-632, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35933612

RESUMO

PURPOSE: To develop a novel instrument for real-time quality assurance (QA) procedures in radiotherapy. The system implements a scintillation-based phantom and associated signal acquisition and processing modules and aims to monitor two-dimensional (2D) dose distributions of small fields. MATERIALS AND METHODS: For the proposed phantom, we have designed and realized a prototype implementing six high-resolution tissue-equivalent scintillating fiber ribbons stacked with in-plane 30° rotated orientations from each other. Each ribbon output is coupled to a silicon photodiode linear array (with an element pitch of 400 µm) to detect scintillating signal, which represents the projected irradiation profile perpendicular to the ribbon's orientation. For the system providing six acquired projected dose profiles at different orientations, we have developed a two-step signal processing method to perform 2D dose reconstruction. The first step is to determine irradiation field geometry parameters using a tomographic geometry approach, and the second one is to perform specific penumbra estimation. The QA system prototype has been tested on a Novalis TrueBeam STX with a 6-MV photon beam for small elliptic fields defined by 5- and 10-mm cone collimators and for 10 × 10- and 20 × 10-mm2 rectangular fields defined by the micro-multileaf collimator. Gamma index analysis using EBT3 films as reference has been carried out with tight 2%-dose-difference (DD)/700-µm-distance-to-agreement (DTA) as well as 1%-DD/1-mm-DTA criteria for evaluating the system performances. The testing also includes an evaluation of the proposed two-step field reconstruction method in comparison with two conventional methods: filtered back projection (FBP) and simultaneous iterative reconstruction technique (SIRT). RESULTS: The reconstructed 2D dose distributions have gamma index pass rates higher than 95% for all the tested configurations as compared with EBT3 film measurements with both 2%-DD/700-µm-DTA and 1%-DD/1-mm criteria. 2D global gamma analysis shows that the two-step and FBP radiation field reconstruction methods systematically outperform the SIRT approach. Moreover, higher gamma index success rates are obtained with the two-step method than with FBP in the case of the fields defined with the stereotactic cones. CONCLUSIONS: The proposed small-field QA system makes a use of six water-equivalent scintillating detectors (fiber ribbons) to acquire dose distribution. The developed two-step signal processing method performs tomographic 2D dose reconstruction. A system prototype has been built and tested using hospital facilities with small rectangular and elliptic fields. Testing results show 2D reconstructed dose distributions with high accuracy and resolution. Such a system could potentially be an alternative approach to film dosimetry for small-field QA, which is still widely used as reference in clinical practice.


Assuntos
Radiometria , Tomografia , Imageamento Tridimensional , Imagens de Fantasmas , Água , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
Sensors (Basel) ; 20(3)2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-32012978

RESUMO

Tackling issues of implantation-caused defects and contamination, this paper presents a new complementary metal-oxide-semiconductor (CMOS) image sensor (CIS) pixel design concept based on a native epitaxial layer for photon detection, charge storage, and charge transfer to the sensing node. To prove this concept, a backside illumination (BSI), p-type, 2-µm-pitch pixel was designed. It integrates a vertical pinned photo gate (PPG), a buried vertical transfer gate (TG), sidewall capacitive deep trench isolation (CDTI), and backside oxide-nitride-oxide (ONO) stack. The designed pixel was fabricated with variations of key parameters for optimization. Testing results showed the following achievements: 13,000 h+ full-well capacity with no lag for charge transfer, 80% quantum efficiency (QE) at 550-nm wavelength, 5 h+/s dark current at 60 °C, 2 h+ temporal noise floor, and 75 dB dynamic range. In comparison with conventional pixel design, the proposed concept could improve CIS performance.

3.
Stud Health Technol Inform ; 264: 74-78, 2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31437888

RESUMO

Personalized medicine implies reducing invasiveness of therapeutic procedures. Although interventional radiology proved a very interesting alternative to surgical procedures, it still raises concerns due to the irradiation dose received by the medical team (and by the patient). We propose a novel concept allowing to reduce very significantly the irradiation dose during the phases where tools inserted in the patient have to be tracked with respect to previously acquired images. This implies inserting a miniaturized X-ray detector in the tip of the tools, and reducing the dose by a "rotating collimator". We demonstrate that real-time processing of the signals allows accurate localization of the tip of the tools, with a dose reduction of at least ten times.


Assuntos
Cateterismo , Radiologia Intervencionista , Interface Usuário-Computador , Fluoroscopia , Humanos , Doses de Radiação , Radiologia Intervencionista/instrumentação
4.
Phys Med Biol ; 58(19): 6701-12, 2013 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24018737

RESUMO

Gallium nitride (GaN), a direct-gap semiconductor that is radioluminescent, can be used as a transducer yielding a high signal from a small detecting volume and thus potentially suitable for use in small fields and for high dose gradients. A common drawback of semiconductor dosimeters with effective atomic numbers higher than soft tissues is that their responses depend on the presence of low energy photons for which the photoelectric cross section varies strongly with atomic number, which may affect the accuracy of dosimetric measurements. To tackle this 'over-response' issue, we propose a model for GaN-based dosimetry with readout correction. The local photon spectrum is calculated by convolving fluence pencil kernel spectra with the beam aperture fluence distribution. The response of a GaN detector is modelled by combining large cavity theory and small cavity theory for the low and high energy components of the local spectrum. Monte Carlo simulations are employed for determination of specific correction factors for different GaN transducer sizes and irradiation conditions. Some model parameters such as the cut-off energy and partitioning energy are discussed. The accuracy of the GaN dosimetric response model has been evaluated for tissue phantom ratio experiments along the central axis. These experiments have shown that calculated and measured GaN responses stay within ±3% at all depths beyond the build-up depth. The calculated GaN response factor is also in good agreement with measured data (±2.5%). The validated model with response compensation improves significantly the accuracy of dosimetric measurements: below 2.5% deviation as compared to 13% without compensation, for a 10 × 10 cm(2) field, at depth from 1.5 to 22 cm.


Assuntos
Gálio , Modelos Teóricos , Fótons/uso terapêutico , Radiometria/instrumentação , Radioterapia/instrumentação , Semicondutores , Método de Monte Carlo
5.
Opt Express ; 20(3): 2053-61, 2012 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-22330446

RESUMO

This paper presents a buried quad p-n junction (BQJ) photodetector fabricated with a HV (high-voltage) CMOS process. Multiple buried junction photodetectors are wavelength-sensitive devices developed for spectral analysis applications where a compact integrated solution is preferred over systems involving bulk optics or a spectrometer due to physical size limitations. The BQJ device presented here is designed for chip-based biochemical analyses using simultaneous fluorescence labeling of multiple analytes such as with advanced labs-on-chip or miniaturized photonics-based biosensors. Modeling and experimental measurements of the spectral response of the device are presented. A matrix-based method for estimating individual spectral components in a compound spectrum is described. The device and analysis method are validated via a test setup using individually modulated LEDs to simulate light from 4-component fluorescence emission.


Assuntos
Fotometria/instrumentação , Semicondutores , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização
6.
Sensors (Basel) ; 9(1): 131-47, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22389592

RESUMO

We present a single-transistor pixel for CMOS image sensors (CIS). It is a floating-body MOSFET structure, which is used as photo-sensing device and source-follower transistor, and can be controlled to store and evacuate charges. Our investigation into this 1T pixel structure includes modeling to obtain analytical description of conversion gain. Model validation has been done by comparing theoretical predictions and experimental results. On the other hand, the 1T pixel structure has been implemented in different configurations, including rectangular-gate and ring-gate designs, and variations of oxidation parameters for the fabrication process. The pixel characteristics are presented and discussed.

7.
Sensors (Basel) ; 8(10): 6566-6594, 2008 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-27873887

RESUMO

A CMOS Buried Double Junction PN (BDJ) photodetector consists of two vertically-stacked photodiodes. It can be operated as a photodiode with improved performance and wavelength-sensitive response. This paper presents a review of this device and its applications. The CMOS implementation and operating principle are firstly described. This includes the description of several key aspects directly related to the device performances, such as surface reflection, photon absorption and electron-hole pair generation, photocurrent and dark current generation, etc. SPICE modelling of the detector is then presented. Next, design and process considerations are proposed in order to improve the BDJ performance. Finally, several BDJ-detector-based image sensors provide a survey of their applications.

8.
Artigo em Inglês | MEDLINE | ID: mdl-18002612

RESUMO

We present an instrumental development to implement electrochemiluminescence (ECL) microanalysis using printed circuit board (PCB) technology. PCB gold macro-(10 mm2) and micro- (0.09 mm2) electrodes and two ECL microfluidic devices are designed, fabricated and tested via luminol ECL detection. Potential modulation is performed between 0.7 and 0 V vs. Ag/AgCl for luminol oxidation, thus giving rise to on/off ECL responses in the presence of hydrogen peroxide. Synchronous detection is adopted to allow weak ECL signal recovery at a very low signal-to-noise ratio (SNR). The detection limit obtained with the two ECL microfluidic devices is 50 nM and 100 nM H2O2 for macroelectrodes and microelectrodes, respectively.


Assuntos
Medições Luminescentes/métodos , Técnicas Analíticas Microfluídicas , Eletroquímica , Eletrônica , Peróxido de Hidrogênio/química , Substâncias Luminescentes/química , Medições Luminescentes/instrumentação , Luminol/química , Microeletrodos , Prata/química , Compostos de Prata/química
9.
Analyst ; 132(5): 409-11, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17471385

RESUMO

This communication presents an instrumental development based on the printed circuit board (PCB) technology to integrate electrochemiluminescence (ECL) analysis in microfluidic systems. PCB gold macro- (10 mm2) and micro- (0.09 mm2) electrodes and two ECL microfluidic devices are designed, fabricated and tested via luminol ECL detection. Potential modulation is performed between 0.7 and 0 V vs. Ag/AgCl for luminol oxidation, thus giving rise to on/off ECL responses in the presence of hydrogen peroxide. Synchronous detection is adopted to allow weak ECL signal recovery at a very low signal-to-noise ratio (SNR). The detection limit obtained with the two ECL microfluidic devices is 50 nM and 100 nM H2O2 for macroelectrodes and microelectrodes, respectively.


Assuntos
Computadores , Técnicas Analíticas Microfluídicas/instrumentação , Eletroquímica/instrumentação , Eletroquímica/métodos , Eletrodos , Ouro , Peróxido de Hidrogênio/análise , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Microeletrodos , Técnicas Analíticas Microfluídicas/métodos , Sensibilidade e Especificidade , Prata