Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Health Phys ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888445

RESUMO

ABSTRACT: Imaging plates can measure isotopes with alpha decay (such as radon and its progeny, americium, and so on). However, the detection efficiency of imaging plates is affected by alpha particle energy, types of imaging plates, and the overlapping effect. In this study, simulations were performed to analyze the relationship between detection efficiency and these three influence factors. The research findings suggest that BAS-TR and BAS-MS are well-suited for the detection of alpha particles with energy levels below 6.83 MeV and above, respectively. The track overlap effect correction method proposed in this study is applicable to both BAS-TR and BAS-MS image plates. The measurement results of radon progeny demonstrate that the correction method enhances the detection efficiency from 0.203 to 0.288. This study presents a valuable approach for selecting the appropriate image plate and correcting the track overlap effect in the measurement of alpha radioactive material concentration and other related information.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...