Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 85(2): 02A706, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593440

RESUMO

PKUNIFTY (PeKing University Neutron Imaging FaciliTY), a thermal neutron imaging facility based on a 2 MeV RFQ accelerator, has been constructed at Peking University. Its deuteron injector, which consists of a 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) deuteron ion source and a two-solenoid low energy beam transport (LEBT), aims at producing and delivering 50 mA, 50 keV deuteron beam with a duty factor of 10% (1 ms, 100 Hz). In the preliminary tests of RFQ accelerator, the ECR ion source and LEBT are required to operate at various duty factors (from 1% to 10%). The deuteron ion source has been tested with different pulse widths for this reason. In order to optimize the transmission parameters, the beam current at the exit of RFQ as a function of solenoids tuning and steering magnets tuning are carefully studied. The beam emittance at the entrance of RFQ has been measured with space charge compensation by different argon gas (RG) pressure from 1.6 × 10(-4) Pa to 4.7 × 10(-3) Pa. The measuring results show the best compensating pressure is 3.5 × 10(-3) Pa with a minimal normalized rms emittance of 0.12 pi mm mrad. During the commissioning, we found the purity of deuteron gas is an important factor which severely affects ECR discharge and plasma intensity inside the ion source chamber. The detailed experimental results obtained during the commissioning are discussed in this paper.

2.
Rev Sci Instrum ; 85(2): 02A927, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593506

RESUMO

At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ&SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D(+), 10 mA of O(+), 10 mA of He(+), and 50 mA of H(+)). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.

3.
Rev Sci Instrum ; 85(2): 02A930, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593509

RESUMO

Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H(+) ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D(+) beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.

4.
Rev Sci Instrum ; 83(2): 02B711, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380316

RESUMO

The deuteron injector developed for the PKUNIFTY (Peking University Neutron Imaging Facility) has been installed and commissioned at Peking University (PKU). The injector system must transfer 50 keV 50 mA of D(+) ion beam to the entrance of the 2 MeV radio frequency quadrupole (RFQ) with 10% duty factor (1 ms, 100 Hz). A compact 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) ion source and a 1.36 m long low energy beam transport (LEBT) line using two solenoids was developed as the deuteron injector. A φ5 mm four-quadrant diaphragm was used to simulate the entrance of RFQ electrodes. The beam parameters are measured after this core with an emittance measurement unit (EMU) and a bending magnet for ion fraction analysis at the end of injector. During the commissioning, 77 mA of total deuteron beam was extracted from PMECR and 56 mA of pure D(+) beam that passed through the φ5 mm four-quadrant diaphragm was obtained at the position of RFQ entrance with the measured normalized rms emittance 0.12-0.16π mm mrad. Ion species analysis results show that the deuteron fraction is as high as 99.5%. All of the parameters satisfy PKUNIFTY's requirements. In this paper, we will describe the deuteron injector design and report the commissioning results as well as the initial operation.

5.
Rev Sci Instrum ; 83(2): 02B905, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380337

RESUMO

An electron cyclotron resonance (ECR) ion source is designed for the production of high-current ion beams of various gaseous elements. At the Peking University (PKU), the primary study is focused on developing suitable permanent magnet ECR ion sources (PMECRs) for separated function radio frequency quadrupole (SFRFQ) accelerator and for Peking University Neutron Imaging Facility. Recently, other kinds of high-intensity ion beams are required for new acceleration structure demonstration, simulation of fusion reactor material irradiation, aviation bearing modification, and other applications. So we expanded the ion beam category from O(+), H(+), and D(+) to N(+), Ar(+), and He(+). Up to now, about 120 mA of H(+), 83 mA of D(+), 50 mA of O(+), 63 mA of N(+), 70 mA of Ar(+), and 65 mA of He(+) extracted at 50 kV through a φ 6 mm aperture were produced by the PMECRs at PKU. Their rms emittances are less than 0.2 π mm mrad. Tungsten samples were irradiated by H(+) or He(+) beam extracted from this ion source and H∕He holes and bubbles have been observed on the samples. A method to produce a high intensity H∕He mixed beam to study synergistic effect is developed for nuclear material irradiation. To design a He(+) beam injector for coupled radio frequency quadruple and SFRFQ cavity, He(+) beam transmission experiments were carried out on PKU low energy beam transport test bench and the transmission was less than 50%. It indicated that some electrode modifications must be done to decrease the divergence of He(+) beam.

6.
Rev Sci Instrum ; 81(2): 02B711, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192451

RESUMO

An experimental method is related to research the space charge compensation (SCC) effect in low energy intense proton beams by analyzing residual gas (RG) ion signals. The signal curves were measured with an energy spectrometer under the RG pressure from 1.2x10(-3) to 1.6x10(-2) Pa. Most of the data showed a similar trend with our theoretical predicts. From the RG ion energy spectra the potential distribution in the beam was calculated both with and without the SCC effect. Moreover, as a preliminary result, a best compensating point is achieved for the low energy beam transport transmission of 40 KeV, 60 mA H(+) beam in Peking University.

7.
Rev Sci Instrum ; 81(2): 02B714, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192454

RESUMO

A deuteron radio frequency quadrupoles injector h has been developed at Peking University. A permanent magnetic electron cyclotron resonance (ECR) ion source is used in the injector system. A 50 keV 100 mA proton beam has been extracted from the ECR ion source and the measured normalized rms emittance is 0.11-0.14pi mm mrad. A deuteron beam has also been extracted at 50 kV with 83 mA total current and its emittance is less than 0.18pi mm mrad. The proton beam transmission has been investigated on a low energy beam transport test bench, and up to 93% transmission can be reached. The new injector with two solenoids has been designed and is being constructed. All the development results will be presented in this paper.

8.
Rev Sci Instrum ; 81(2): 02B715, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192455

RESUMO

A set of new ion extraction electrodes have been designed for the permanent magnetic electron cyclotron resonance ion source at Peking University to improve beam quality and transmission. PBGUNS has been used to optimize the extraction electrodes and simulate the beam behavior at the extraction region. The experiments showed that with the new system, the beam half divergence angle can be less than 40 mrad and the normalized rms emittance is about 0.13pi mm mrad when the extracted current is 100 mA at 50 keV in pulse mode. The voltage of the suppression electrode has great effect on beam divergence. The effect of the microwave power and gas flow is also studied.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...