Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 33(11): 7769-7778, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37171489

RESUMO

OBJECTIVES: To determine whether dual-energy CT (DECT) can be used to accurately and reliably detect anterior cruciate ligament (ACL) rupture. MATERIALS AND METHODS: Participants with unilateral ACL rupture were prospectively enrolled, and the bilateral knees were scanned by DECT. A tissue-specific mapping algorithm was applied to improve the visualization of the ACLs. The 80-keV CT value, mixed-keV CT value, electron density (Rho), and effective atomic number (Zeff) were measured to quantitatively differentiate torn ACLs from normal ACLs. MRI and arthroscopy served as the reference standards. RESULTS: Fifty-one participants (mean age, 27.0 ± 8.7 years; 31 men) were enrolled. Intact and torn ACLs were explicitly differentiated on color-coded DECT images. The 80-keV CT value, mixed-keV CT value, and Rho were significantly lower for the torn ACLs than for the intact ACLs (p < 0.001). The optimal cutoff values were an 80-keV CT value of 61.8 HU, a mixed-keV CT value of 60.9 HU, and a Rho of 51.8 HU, with AUCs of 98.0% (95% CI: 97.0-98.9%), 99.2% (95% CI: 98.6-99.7%), and 99.8% (95% CI: 99.6-100.0%), respectively. Overall, DECT had almost perfect reliability and validity in detecting ACL integrity (sensitivity = 97.1% [95% CI: 88.1-99.8%]; specificity = 98.0% [95% CI: 89.5-99.9%]; PPV = 98.0% [95% CI: 93.0-99.8%]; NPV = 97.1% [95% CI: 91.7-99.4%]; accuracy = 97.5% [95% CI: 94.3-99.2%]). There was no evidence of a difference between MRI and DECT in the diagnostic performance (p > 0.99). CONCLUSION: DECT has excellent diagnostic accuracy and reliability in qualitatively and quantitatively diagnosing ACL rupture. CLINICAL RELEVANCE STATEMENT: DECT could validly and reliably diagnose ACL rupture using both qualitative and quantitative methods, which may become a promising substitute for MRI to evaluate the integrity of injured ACLs and the maturity of postoperative ACL autografts. KEY POINTS: • On color-coded DECT images, an uncolored ACL was a reliable sign for qualitatively diagnosing ACL rupture. • The 80-keV CT value, mixed-keV CT value, and Rho were significantly lower for the torn ACLs than for the intact ACLs, which contributed to the quantitative diagnosis of ACL rupture. • DECT had an almost perfect diagnostic performance for ACL rupture, and diagnostic capability was comparable between MRI and DECT.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/cirurgia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Tomografia Computadorizada por Raios X/métodos
2.
Knee Surg Sports Traumatol Arthrosc ; 31(6): 2374-2385, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36138208

RESUMO

PURPOSE: To evaluate the extent of tunnel widening after anterior cruciate ligament reconstruction (ACLR) using the all-inside technique and to establish its correlation with patient-reported clinical outcomes and femoral graft bending angle (GBA). METHODS: Tunnel widening was evaluated using computed tomography (CT)-based three-dimensional (3D) models, and the femoral GBA was directly measured on CT images using the Picture Archiving and Communication System (PACS) software. Clinical follow-up was routine procedure, and patient-reported clinical outcomes mainly included International Knee Documentation Committee (IKDC), Lysholm, and Knee Injury and Osteoarthritis Outcome Scores (KOOS) scores, and subjective knee stability assessment. RESULTS: Fifty-two patients received standard all-inside ACLR, with a median follow-up of 6 months. Reconstructed anterior cruciate ligaments (ACLs) were scanned during the first 3 days and 6 months after surgery. On both the femoral and tibial sides, bone tunnels were most significantly enlarged at the articular aperture segment; the femoral tunnel was 9.2 ± 1.3 mm postoperatively and was significantly enlarged by 32% to a mean tunnel diameter of 12.1 ± 2.0 mm at 6 months after surgery. Moreover, the extent of tunnel enlargement gradually decreased as the measured levels approached those of the bone cortex. The femoral tunnel center was shifted into the anterior and distal direction, and the tibial tunnel center was shifted into the posterior and lateral direction. Additionally, the mean femoral GBA was 105.9° ± 8.1° at the 6-month follow-up. Tunnel enlargement and GBA were not significantly correlated with patient-reported outcomes. CONCLUSIONS: Femoral and tibial tunnels were significantly greater and eccentrically shifted at the 6-month follow-up after all-side ACLR. However, the extent of tunnel widening does not markedly affect the short-term clinical outcomes. Meanwhile, the femoral GBA was not significantly correlated with femoral tunnel widening or patient-reported outcomes. Although the tunnel widening following all-inside ACLR was not associated with clinical outcomes, it potentially caused difficulties in revision ACLR. LEVEL OF EVIDENCE: Level IV.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Tomografia Computadorizada por Raios X/métodos , Reconstrução do Ligamento Cruzado Anterior/métodos , Hipertrofia/cirurgia
3.
J Org Chem ; 83(12): 6423-6431, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29779383

RESUMO

A one-pot cascade heterocyclization strategy has been developed for the synthesis of 2,4-dichloro-substituted pyrano[2,3- d]pyrimidines and furo[2,3- d]pyrimidines from linear γ- and ß-ketomalononitriles using triphosgene and triphenylphosphine oxide. The reaction afforded synthetic useful products with moderate to good yields, bypassing the conventional harsh conditions of chlorination. The mechanistic study revealed that the reaction proceeded with a non-isocyanate route, and the second step may conduct in a triphenylphosphine oxide-catalyzed manner.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...