Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Cell Infect Microbiol ; 14: 1343338, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38746784

RESUMO

Objectives: To investigate the efficacy of serum protein electrophoresis (SPE) in the diagnosis of periprosthetic joint infection (PJI) after hip and knee arthroplasty. Methods: The medical records of patients undergoing hip and knee arthroplasty at a class A tertiary hospital between August 2013 and January 2021 were retrospectively investigated. A total of 179 patients were included and divided into two groups: 66 patients in the PJI group and 113 patients in the aseptic loosening (AL) group. Serum C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), D-dimer, Fibrinogen, Serum albumin and the proportion of serum protein in SPE were compared between the two groups. The diagnostic sensitivity and specificity were determined using the receiver operating characteristic (ROC) curve, and the diagnostic value was compared using the area under the ROC curve (AUC). Results: There was no significant difference in age, sex and body mass index (BMI) between PJI group and AL group (P>0.05), but there was significant difference in the ratio of hip to knee (X2 = 22.043, P<0.001). The CRP, ESR, D-dimer, Fibrinogen and the proportion of α1 globulin band in PJI group was 22.99(10.55,40.58) mg/L, 37.00(23.00,61.70) mm/h, 790.00(500.00,1500.00) ng/ml, 4.84(3.81,5.55) g/L and 5.80(5.00,7.73) % which was higher than that in AL group [1.89(0.50,4.12) mg/L, U=7.984, P<0.001; 10.10(7.00,16.90) mm/h, U=8.095, P<0.001; 570.00(372.50,780.00) ng/ml, U=3.448, P<0.001; 2.84(2.45,3.43) g/L, U=8.053, P<0.001 and 4.20(3.90,4.80) %, U=8.154, P<0.001]. The Serum albumin and the proportion of Albumin band in PJI group was 36.10(33.10,39.00) g/L and 49.00(44.95,52.20) % which was lower than that in AL group [38.10(34.00,41.10) g/L, U=-2.383, P=0.017 and 54.40(51.55,56.70) %, U=-6.162, P<0.001]. The proportion of In PJI group, the AUC of proportion of α1 globulin was 0.8654, which was equivalent to CRP (0.8698), ESR (0.8680) and outperformed that of fibrinogen (0.8025). Conclusions: Elevated proportion of α1 globulin in SPE presented with good diagnostic value for Tsukayama type IV PJI, and its accuracy was comparable to those of ESR and CRP. And α1 globulin can assist with CRP and ESR to determining the timing of second-stage revision.


Assuntos
Artroplastia do Joelho , Sedimentação Sanguínea , Proteína C-Reativa , Infecções Relacionadas à Prótese , Curva ROC , Humanos , Feminino , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/sangue , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Proteína C-Reativa/análise , Artroplastia do Joelho/efeitos adversos , Proteínas Sanguíneas/análise , Artroplastia de Quadril/efeitos adversos , Sensibilidade e Especificidade , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Fibrinogênio/análise , Fibrinogênio/metabolismo , Eletroforese das Proteínas Sanguíneas/métodos , Idoso de 80 Anos ou mais
2.
J Robot Surg ; 18(1): 79, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365906

RESUMO

Postoperative complications due to inaccurate prosthesis positioning are the main causes of early revision. The aim of this study was to (1) determine whether novel designed whole-process robotic assisted hip system allowed better radiographic outcomes and lower complications risk on the femoral side particularly stem subsidence compared to conventional THA, and to (2) identify the comparison of early clinical outcomes. 72 patients were initially enrolled and randomly divided into 2 groups. Finally, only 65 patients (31 RA-THAs, 34 C-THAs) were analyzed who had full 18-month follow-up data. Radiographic follow-up was performed at immediate and 6-month postoperatively, while clinical follow-up at 18-month postoperatively. Stem-related radiographic outcomes, femoral side complications and clinical scores were compared. The robotic arm allowed better radiographic outcomes of the femoral side, including a higher canal fill ratio (CFR) at B1 (P = 0.040), more neutral stem alignment (P = 0.029), lower subsidence (P = 0.023) and lower leg length discrepancy (LLD) (P = 0.010). In addition, low CFR at B1 (P = 0.001) was found the risk factor for subsidence. However, early clinical outcomes were consistent between both groups. The novel designed whole-process robotic assisted hip system covers both femoral and acetabular side operations. It allows accurate and safe manipulation of femoral side, including better stem-related radiographic outcomes and lower risk of subsidence and LLD. However, no advantage of robotic system in early clinical score was identified. Clinical trial registration number: ChiCTR2100044124.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Resultado do Tratamento , Estudos Retrospectivos
3.
Int J Surg ; 110(4): 2141-2150, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38241325

RESUMO

OBJECTIVE: To compare the effect of a new complete robot-assisted total hip arthroplasty (RA-THA) with that of the manual total hip arthroplasty (MTHA) and to verify the accuracy and safety of the former. METHODS: Overall, 148 patients were enroled from 3 March 2021 to 28 December 2021 in this study and classified into RA-THA ( n =74 patients) and MTHA ( n =74 patients) groups. The sex, age, operative side, BMI, diagnosis, other basic information, operative time, acetabular prosthesis anteversion and inclination, femoral prosthesis anteversion and angulation, femoral prosthesis filling rate, leg length discrepancy (LLD), Harris hip score, and visual analogue scale (VAS) score of the two groups were compared. RESULTS: No significant differences were observed in the two groups regarding sex, age, operative side, BMI, diagnosis, Harris hip score, VAS score, acetabular inclination, acetabular prosthesis anteversion, femoral prosthesis anteversion, combined anteversion, and femoral prosthesis filling rate ( P >0.05). The operative time was significantly longer in the RA-THA group than in the MTHA group (106.71±25.22 min vs. 79.42±16.16 min; t=7.30, P <0.05). The femoral angulation (1.78°±0.64°) and LLD (2.87±1.55 mm) in the RA-THA group were significantly lesser than those in the MTHA group (2.22°±1.11° and 5.81±6.27 mm, respectively; t=-2.95 and t=-3.88, P <0.05). CONCLUSION: The complete RA-THA has some advantages over the traditional procedure in restoring the lower limb length and controlling the femoral prosthesis angulation. Thus, this study verifies the accuracy and safety of the robot-assisted system.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Feminino , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Pessoa de Meia-Idade , Idoso , Duração da Cirurgia , Resultado do Tratamento , Prótese de Quadril
4.
J Orthop Surg Res ; 18(1): 830, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37924147

RESUMO

BACKGROUND: To investigate the accuracy and safety of a newly constructed robotic arm which can cover the whole process of THA, we performed a series of robot-assisted total hip replacement on the cadaver. METHODS: Fifteen frozen cadaveric specimens (30 hips) were used for this study. In this investigation, united hip system and Longwell robotic-assisted system were used. The entire lower limb was CT scanned prior to surgery. The 3D model was produced based on CT data; the site of the prosthesis, including acetabular anteversion, inclination angle, and the position of femoral prosthesis, was planned. With the assistance of a robotic arm, the surgeon changed the parameters based on the preoperative plan and the actual condition during surgery, and completed the whole procedure. Following surgery, we measured the acetabular anteversion angle, acetabular inclination angle, femur anteversion angle, combined anteversion angle, stem angulation, and canal fill ratio. RESULTS: The parameters proved that the acetabular anteversion angle was 16.85 ± 3.00°, the acetabular inclination angle was 40.38 ± 5.37°, femur anteversion angle was 15.90 ± 9.01°, combined anteversion angle was 32.75 ± 9.03°, stem angulation was 1.84 ± 0.99°, and leg length discrepancy was 2.47 ± 1.43 mm. The canal fill ratio (CFR) of femoral prosthesis of osteotomy line in sagittal section is 99.72 ± 1.54% and in coronal section is 62.94 ± 8.91%; below osteotomy line 2.5 cm in sagittal section is 100.00% and in coronal section is 81.48 ± 12.94%; below osteotomy line 7.5 cm in sagittal section is 59.51 ± 12.94% and in coronal section is 89.79 ± 11.13%; femoral shaft isthmus in sagittal section is 56.41 ± 13.80% and in coronal section is 84.95 ± 15.17%. CONCLUSION: The accuracy and safety of this novel robotic arm are suitable for preparing both the acetabular and femoral sides, providing evidence for clinical trial.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Cadáver
5.
Front Med (Lausanne) ; 10: 1212580, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795417

RESUMO

Ochronosis is a rare autosomal recessive disorder of tyrosine metabolism characterized by multilevel spinal degeneration and arthritis of large weight-bearing joints, which is referred to as ochronotic arthropathy. In this case report, we describe diagnosis and treatment of ochronotic arthropathy in a patient who underwent total hip arthroplasty (THA) and total knee arthroplasty (TKA). The Harris hip score was 26 preoperatively and 45, 68, 76, 90, 92, and 94 at 1, 3, 6, 9, 11, and 14 months, respectively, postoperatively. The forgotten joint score (FJS) of the hip was 27.8, 52.8, 81.1, 89.0, 90.6, and 92.4 at 1, 3, 6, 9, 11, and 14 months, respectively, postoperatively. TKA was performed 8 months after THA. The Knee Society Score was 36 before TKA and 74, 82, and 90 at 1, 3, and 6 months, respectively, after TKA. The FJS of the knee was 36.6, 63.9, and 84.5 at 1, 3, and 6 months, respectively, after TKA. The patient's knee range of motion returned to normal, with significant reduction in pain and improved satisfaction levels after TKA. THA and TKA can achieve good clinical outcomes in patients with ochronosis accompanied by severe joint pain.

6.
Int Immunopharmacol ; 121: 110506, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37343371

RESUMO

Osteoarthritis (OA) is a prevalent disease among elderly individuals that is caused by cartilage degeneration. Chondrocyte senescence involved in the development of OA, and antisenescence therapies have been proposed for OA treatment. In our study, we identified the role of a microRNA, miR-33-5p, in promoting chondrocyte senescence and OA progression. miR-33-5p expression was upregulated under senescence conditions. miR-33-5p-mimic transfection can induce cellular senescence, while transfection of a miR-33-5p-inhibitor in chondrocytes alleviated senescence induced by IL-1ß. Moreover, SIRT6 expression was downregulated under IL-1ß treatment, and could be restored by miR-33-5p-inhibitor transfection. Luciferase assays revealed that miR-33-5p targeted the SIRT6 mRNA 3' UTR. In addition, SIRT6 mRNA expression showed negative correlations with senescence and OA degree in human cartilage. Bioinformatic analysis also confirmed the pro-senescence effect of miR-33-5p. Furthermore, periodic intraarticular injection of agomiR-33-5p induced cartilage loss and OA-like cartilage changes. To conclude, we revealed the pro-senescence and cartilage-destructive effect of miR-33-5p, whose expression was elevated under various senescence conditions, and showed that SIRT6 was one of its targets. Therefore, miR-33-5p is a potential therapeutic target for treating OA.


Assuntos
MicroRNAs , Osteoartrite , Sirtuínas , Humanos , Idoso , Condrócitos , MicroRNAs/metabolismo , Osteoartrite/metabolismo , Interleucina-1beta/metabolismo , Apoptose , RNA Mensageiro/metabolismo , Sirtuínas/metabolismo
7.
J Orthop Surg Res ; 18(1): 408, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37277763

RESUMO

BACKGROUND: Leg length discrepancy (LLD) is a common complication of total hip arthroplasty (THA). However, the relationship between femoral prosthesis filling, proximal femoral morphology, and acetabular prosthesis positioning with postoperative LLD and clinical outcomes is unclear. The aims of this study were to investigate the influence of canal flare index (CFI), canal fill ratio (CFR), center of rotation (COR), and femoral offset (FO) on (1) postoperative LLD; and (2) clinical outcomes in the two stem designs with different coating distribution. METHODS: The study cohort included 161 patients who underwent primary cementless THA between January 2021 and March 2022 with either proximal coating or full coating stems. Multivariate logistic regression was used to assess the effect of CFI, CFR, COR, and FO on postoperative LLD, and linear regression to assess their effect on clinical outcomes. RESULTS: No statistical difference was found in clinical outcomes or postoperative LLD between the two groups. High CFI (p = 0.014), low ΔVCOR (p = 0.012), and Gender (p = 0.028) were found independent risk factors for LLD one day postoperative. High CFI was also an independent risk factor for postoperative subjectively perceived LLD (p = 0.013). CFR at the level of 2 cm below the LT (p = 0.017) was an independent risk factor for Harris Hip Score. CONCLUSIONS: Proximal femoral morphology and acetabular prosthesis positioning but not femoral prosthesis filling affected the LLD. High CFI was an independent risk factor for postoperative LLD and subjectively perceived LLD, and low ΔVCOR was also an independent risk factor for postoperative LLD. Women were susceptible to postoperative LLD.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Perna (Membro) , Estudos Retrospectivos , Prótese de Quadril/efeitos adversos , Fatores de Risco , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/etiologia
8.
Int Orthop ; 47(2): 413-419, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35802187

RESUMO

INTRODUCTION: The purpose of this article is to study whether the newly designed whole-process total hip arthroplasty (THA) robotic arm can improve the accuracy of prosthesis placement in THA. METHOD: In this study, 72 patients undergoing THA were prospectively included and randomly divided into two groups. The experimental group was treated with THA assisted by a newly designed robotic arm. The control group received THA with conventional surgical methods. The imaging data were compared after operation. RESULT: Compared with the conventional operation, the whole-process robotic arm can more accurately place the acetabular prosthesis in the anteversion safe zone of 5 ~ 25°, but in terms of the inclination angle, whether the reference is the safe zone of 30 ~ 50° or 30 ~ 45°, there is no statistical difference between the two groups. The average lower limb length discrepancy (LLLD) in the experimental group was 3.77 ± 8.31 mm longer than contralateral side, while the counterpart in the control group was 8.39 ± 9.11 mm, with significant difference (P = 0.029). The femoral prosthesis was fixed in neutral position in 35 (100%) cases in the experimental group and only 30 (83.3%) in the control group (P = 0.036). There was no significant difference in the recovery of hip offset, femoral anteversion, and canal fill ratio (CFR) between the two groups. CONCLUSION: Robotic arm can improve the accuracy of anteversion of acetabular cup, restore the consistency of the length of lower limbs, and more accurately implant the femoral prosthesis to the neutral position in the coronal position. CLINICAL TRIAL REGISTRATION NUMBER: ChiCTR2100044124 (date of registration: 2021-3-11).


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia
9.
Environ Sci Pollut Res Int ; 29(51): 77580-77592, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35678968

RESUMO

This study was carried out to evaluate the contribution of different types of iron-organic matter associations (Fe-OM) to the phosphorus sorption capacity of peatland. Humic substance (HS) and particulate organic matter (POM) were isolated from peat soils, and different types of iron-organic matter associations (Fe-HS and Fe-POM) were prepared. Then, isothermal adsorption experiments were carried out on the synthesized Fe-OM and iron-contained peat soils. The morphology structure of Fe-HS associations is amorphous like that of ferrihydrite. The theoretical maximum adsorption capacity (Qmax) of Fe-HS associations can reach 36.90 mg/g, which is approximately two times higher than that of ferrihydrite (19.23 mg/g) and ten times higher than that of hematite (3.26 mg/g) and goethite (2.08 mg/g). Both peat soils and POM can strongly complex ferric ions, resulting in improved phosphorus sorption capacity. The Qmax of original peat soil and POM is 2.83 mg/g and 4.31 mg/g, which increased to 7.36 mg/g and 5.89 mg/g, respectively, after complexing ferric ions. Compared to inorganic Fe minerals, the associations of iron and organic matter (HS and POM) contribute more to the phosphorus retention ability of peat soils. However, the formation of Fe-OM associations could not fully explain why the addition of iron increases the phosphorus sorption capacity of peat soil by so much. Iron should also participate in other phosphorus retention processes, which need further exploration and research.


Assuntos
Ferro , Solo , Solo/química , Ferro/química , Fósforo/química , Substâncias Húmicas/análise , Compostos Férricos/química , Minerais , Adsorção
10.
J Orthop Surg Res ; 17(1): 61, 2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35093133

RESUMO

OBJECTIVE: This study assessed the accuracy of robotic-arm-assisted total knee arthroplasty (RATKA) for bone resection, component size prediction, implant placement, and limb alignment. METHODS: This prospective cohort study included 36 patients. All procedures were performed by a single experienced surgeon, using an identical approach and implant designs. The MAKO RIO Robotic Interactive Orthopaedic Arm (Stryker, Mahwah, NJ, USA) system was used. The actual bone resection, implant placement, component size, and postoperative mechanical alignment were recorded, then compared with the preoperative plan. RESULTS: The mean absolute differences from the plan for the distal (medial and lateral) and posterior (medial and lateral) femoral cuts were 0.39 mm (0.62), 0.49 mm (0.70), 0.62 mm (0.79), and 0.65 mm (0.81), respectively, with 0.57° (0.65) varus. The mean absolute differences in the medial and lateral tibial cuts were 0.56 mm (0.75) and 0.58 mm (0.76), with 0.48° (0.16) varus and 0.54° (0.25) anterior/posterior slope. Of 192 bone resections, 176 (91.7%) were within ≤ 1 mm of the preoperative plan. The accuracies of femoral and tibial component size prediction were 100% and 97.22%, respectively. The mean absolute difference in final limb coronal alignment was 0.92° (0.65). Of the alignments, 18 (75.0%) were within ≤ 1.00° of the plan, and 100% were within ≤ 3.00° of the plan. CONCLUSION: RATKA could accurately predict the component size and execute a preoperative plan to achieve precise bone resection, and implant placement, thereby reducing alignment outliers.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Braço , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...