1.
Talanta ; 226: 122101, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33676657

RESUMO

Temperature changes in cells are generally accompanied by physiological processes. Cellular temperature measurements can provide important information to fully understand cellular mechanisms. However, temperature measurements with conventional methods, such as fluorescent polymeric thermometers and thermocouples, have limitations of low sensitivity or cell state disturbance. We developed a microfluidic chip integrating a high-precision platinum (Pt) thermo-sensor that can culture cells and monitor the cellular temperature in situ. During detection, a constant temperature system with a stability of 0.015 °C was applied. The temperature coefficient of resistance of the Pt thermo-sensor was 2090 ppm/°C, giving a temperature resolution of the sensor of less than 0.008 °C. This microchip showed a good linear correlation between the temperature and resistance of the Pt sensor at 20-40 °C (R2 = 0.999). Lung and liver cancer cells on the microchip grew normally and continuously. The maximum temperature fluctuation of H1975 (0.924 °C) was larger than that of HepG2 (0.250 °C). However, the temperature of adherent HepG2 cells changed over time, showing susceptibility to the environment most of the time compared to H1975. Moreover, the temperature increment of non-cancerous cells, such as hepatic stellate cells, was monitored in response to the stimulus of paraformaldehyde, showing the process of cell death. Therefore, this thermometric microchip integrated with cell culture could be a non-disposable and label-free tool for monitoring cellular temperature applied to the study of physiology and pathology.


Assuntos
Neoplasias , Fenômenos Fisiológicos , Termometria , Humanos , Microfluídica , Termômetros
2.
Analyst ; 146(6): 1956-1964, 2021 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-33496286

RESUMO

Chemical oxygen demand (COD) is one of the key water quality parameters in environmental monitoring. However, fabricating a COD sensor with the characteristic of batch-processing and rapid measurement is always a challenging issue. This paper reports a microfluidic electrochemical sensor for the organic matter measurement based on advanced oxidization within a fixed microvolume detection chamber by a microfabrication technique/MEMS. By fabricating a silicon-based Ag/AgCl reference electrode and employing PbO2 as the working electrode with Pt as the counter electrode, we verified the superiority of the as-fabricated sensor by continuous potassium acid phthalate detection; an acceptable limit of detection (4.17 mg L-1-200 mg L-1), a low limit of detection (2.05 mg L-1), a desirable linearity (R2 = 0.982) and relative stability at different pH values and Cl- concentrations was witnessed. Particularly, a shorter detection time (2 s) was witnessed for the as-proposed sensor compared with traditional organic matter measurement methods. Each sensing process takes only 2 seconds for sensing because a micro-cavity with a volume of 2.5 µL was fabricated and used as a detection pool. Moreover, as the sensor was fabricated by a mass-production technique, potential response consistency of multiple sensors was expected and was verified via a series of parallel experiments. In this paper, a miniaturized (8 mm × 10 mm), low-cost and reliable COD sensor was designed and fabricated by MEMS, and it provided a core sensor component for construction of an online water environment monitoring network to meet the substantial demand for COD sensors in the Internet of Things (IOT) era.

3.
Molecules ; 24(23)2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31779185

RESUMO

The high crystallization at room temperature and high cost of polyoxytetramethylene glycol (PTMG) have become obstacles to its application. To overcome these problems, a segment of PTMG can be incorporated into a block copolymer. In this work, polypropylene (PPO) glycol-polyoxytetramethylene (PPO-PTMG) multiblock copolymers were designed and synthesized through a chain extension between hydroxyl (OH)-terminated PPO and PTMG oligomers. The chain extenders, feed ratios of the catalyst/chain extender/OH groups, reaction temperature, and time were optimized several times to obtain a PPO-PTMG with low crystallization and high molecular weight. Multiblock copolymers with low crystallization and high average molecular weight (Mn = 1.0-1.4 × 104 Dalton) were harvested using m-phthaloyl chloride as the chain extender. The OH-terminated PPO-PTMG multiblock copolymer with high Mn and a functionality near two was further siliconized by 3-isocyanatopropyltrimethoxysilane to synthesize a novel silyl-terminated polyether. This polyether has an appropriate vulcanizing property and potential applications in sealants/adhesive fields.


Assuntos
Metanol/análogos & derivados , Polímeros/química , Propilenoglicóis/química , Adesivos/química , Materiais Biocompatíveis/química , Metanol/química , Peso Molecular , Poliésteres/química , Polietilenoglicóis/química , Temperatura