1.
Clin Ophthalmol ; 15: 1647-1657, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33907378

RESUMO

PURPOSE: This study assessed effectiveness and safety of the novel Clareon intraocular lens (IOL; model SY60CL; Alcon Vision LLC). PATIENTS AND METHODS: This was a prospective, single-arm, unmasked clinical trial at 16 investigative clinical sites in the United States. Included were adults ≥22 years who required cataract extraction by phacoemulsification. Following phacoemulsification, 350 subjects received SY60CL IOL unilaterally; 342 completed the study. Monocular best corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) were evaluated. The primary effectiveness endpoint was the percentage of subjects with CDVA ≤0.3 logMAR at month 12. Safety was assessed by monitoring adverse events (AEs). Visual acuity and safety outcomes were compared with historical safety and performance endpoint (SPE) rates. RESULTS: At 12 months post-implantation, 99.7% of subjects receiving the SY60CL IOL achieved monocular CDVA ≤0.3 logMAR (primary effectiveness endpoint; 1-sided 95% upper confidence limit >SPE rate); 99.7% and 86.8% of subjects achieved monocular CDVA of ≤0.34 (20/40 Snellen or better) and ≤0.04 logMAR (20/20 Snellen or better), respectively. At 12 months, >95% of subjects achieved mean monocular UDVA ≤0.3 logMAR; 97.1% and 57.6% of subjects achieved monocular CDVA of ≤0.34 and ≤0.04 logMAR, respectively. Mean monocular CDVA and UDVA were -0.05 and 0.04 logMAR, respectively. AEs were within SPE limits. The most common nonserious ocular AE was posterior capsule opacification (5.4%). Serious AEs were <1%, and no serious ocular AEs were assessed as related to the device. There were no observations for IOL glistenings at 12 months. CONCLUSION: Results of this study supported effectiveness and safety of the SY60CL IOL. Visual acuity outcomes with the SY60CL IOL exceeded the SPE rates for monocular CDVA and AEs were within the limit of historic SPE rates. (Model number SY60WF is the Clareon lens approved by the FDA.).

2.
Ophthalmology ; 126(6): 811-821, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30880108

RESUMO

PURPOSE: Evaluate the safety and effectiveness of an ab interno implanted (iStent inject) Trabecular Micro-Bypass System (Glaukos Corporation, San Clemente, CA) in combination with cataract surgery in subjects with mild to moderate primary open-angle glaucoma (POAG). DESIGN: Prospective, randomized, single-masked, concurrently controlled, multicenter clinical trial. PARTICIPANTS: Eyes with mild to moderate POAG and preoperative intraocular pressure (IOP) ≤24 mmHg on 1 to 3 medications, unmedicated diurnal IOP (DIOP) 21 to 36 mmHg, and cataract requiring surgery. METHODS: After uncomplicated cataract surgery, eyes were randomized 3:1 intraoperatively to ab interno implantation of iStent inject (Model G2-M-IS; treatment group, n = 387) or no stent implantation (control group, n = 118). Subjects were followed through 2 years postoperatively. Annual washout of ocular hypotensive medication was performed. MAIN OUTCOME MEASURES: Effectiveness end points were ≥20% reduction from baseline in month 24 unmedicated DIOP and change in unmedicated month 24 DIOP from baseline. Safety measures included best spectacle-corrected visual acuity (BSCVA), slit-lamp and fundus examinations, gonioscopy, pachymetry, specular microscopy, visual fields, complications, and adverse events. RESULTS: The groups were well balanced preoperatively, including medicated IOP (17.5 mmHg in both groups) and unmedicated DIOP (24.8±3.3 mmHg vs. 24.5±3.1 mmHg in the treatment and control groups, respectively, P = 0.33). At 24 months, 75.8% of treatment eyes versus 61.9% of control eyes experienced ≥20% reduction from baseline in unmedicated DIOP (P = 0.005), and mean reduction in unmedicated DIOP from baseline was greater in treatment eyes (7.0±4.0 mmHg) than in control eyes (5.4±3.7 mmHg; P < 0.001). Of the responders, 84% of treatment eyes and 67% of control eyes were not receiving ocular hypotensive medication at 23 months. Furthermore, 63.2% of treatment eyes versus 50.0% of control eyes had month 24 medication-free DIOP ≤18 mmHg (difference 13.2%; 95% confidence interval, 2.9-23.4). The overall safety profile of the treatment group was favorable and similar to that in the control group throughout the 2-year follow-up. CONCLUSIONS: Clinically and statistically greater reductions in IOP without medication were achieved after iStent inject implantation with cataract surgery versus cataract surgery alone, with excellent safety through 2 years.


Assuntos
Catarata/complicações , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Facoemulsificação , Malha Trabecular/cirurgia , Idoso , Anti-Hipertensivos/administração & dosagem , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Stents , Tonometria Ocular , Acuidade Visual/fisiologia , Campos Visuais/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...