Electrophoresis ; 34(3): 432-40, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23151975

RESUMO

Adsorption processes on a PMMA chip linked with CZE separations of a group of 13 aliphatic and aromatic mono- and di-amines were studied. Due to the lack of chromophores within aliphatic amines, contact conductivity detection implemented directly onto the chip was used for monitoring of cationic CZE separations. To prevent an adsorption of studied amines to the chip channels, the surface of PMMA chip was modified by dynamic coating. Different surface modifiers, such as aliphatic oligoamines (diethylenetriamine and triethylenetetramine), were added to the BGE solutions filling the chip channels. The effect of various concentrations of surface modifiers on peak profiles and separation parameters of amines was monitored. Of these, mainly, aliphatic di-amines and aromatic mono-amines adversely affected the CZE resolution of a whole group of analytes by their strong adsorption to the chip channels. A propionate BGE with pH 3.2 containing 100 µM triethylenetetramine and 25 mM 18-crown-6-ether was found suitable for CZE resolution of 12 from a total of 13 amines studied. Simple dynamic modification of the surface of PMMA chip enabled fast (analysis time lasted 9 min), sensitive (sub-µM LODs reached) and reproducible (1-3% RSD of the peak areas) CZE analysis of the aliphatic and aromatic amines.


Assuntos
Aminas/análise , Eletroforese Capilar/métodos , Polimetil Metacrilato/química , Adsorção , Aminas/química , Aminas/metabolismo , Condutividade Elétrica , Eletroforese Capilar/instrumentação , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Análise de Regressão , Reprodutibilidade dos Testes
2.
J Sep Sci ; 34(13): 1561-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21595032

RESUMO

Analytical potentialities of a chip-based CE in determination of ammonium in wastewaters were investigated. CZE with the electric field and/or ITP sample stacking was performed on a column-coupling (CC) chip with integrated conductivity detectors. Acetate background electrolytes (pH ∼3) including 18-crown-6-ether (18-crown-6) and tartaric acid were developed to reach rapid (in 7-8 min) CZE and ITP-CZE resolutions of ammonium from other cations (sodium, potassium, calcium and magnesium) present in wastewater samples. Under preferred working conditions (suppressed hydrodynamic flow (HDF) and EOF on the column-coupling chip), both the employed methods did provide very good repeatabilities of the migration (RSD of 0.2-0.8% for the migration time) and quantitative (RSD of 0.3-4.9% for the peak area) parameters in the model and wastewater samples. Using a 900-nL sample injection volume, LOD for ammonium were obtained at 20 and 40 µg/L concentrations in CZE and ITP-CZE separations, respectively. Very good agreements of the CZE and ITP-CZE determinations of ammonium in six untreated wastewater samples (only filtration and dilution) with the results obtained by a reference spectrometric method indicate a very good accuracy of both the CE methods presented.


Assuntos
Eletroforese Capilar/métodos , Compostos de Amônio Quaternário/análise , Esgotos/análise , Poluentes Químicos da Água/análise , Eletroforese Capilar/instrumentação
3.
J Chromatogr A ; 1216(34): 6252-5, 2009 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-19616216

RESUMO

This work deals with simultaneous determination of ammonium, calcium, magnesium, sodium and potassium in drinking waters by capillary zone electrophoresis (CZE) on a column-coupling (CC) chip with suppressed hydrodynamic and electroosmotic transports. CZE separations were carried out in a propionate background electrolyte at a low pH (3.2) containing 18-crown-6-ether (18-crown-6) to reach a complete resolution of the cations. In addition, triethylenetetramine (TETA) coated the inner wall surface of the chip channels. The concentration limits of detection (cLOD) for the studied cations ranged from 4.9 to 11.5 microg/l concentrations using a 900 nl volume of the sample injection channel. 93-106% recoveries of the cations in drinking waters indicate a good predisposition of the present method to provide accurate analytical results.


Assuntos
Eletroforese Capilar , Poluentes Químicos da Água/análise , Água/química , Cálcio/análise , Cálcio/isolamento & purificação , Eletrocromatografia Capilar , Éteres de Coroa , Eletroforese Capilar/instrumentação , Magnésio/análise , Magnésio/isolamento & purificação , Polimetil Metacrilato , Potássio/análise , Potássio/isolamento & purificação , Compostos de Amônio Quaternário/análise , Compostos de Amônio Quaternário/isolamento & purificação , Sódio/análise , Sódio/isolamento & purificação , Trientina