1.
J Vis Exp ; (182)2022 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-35499356

RESUMO

The capillary aerosol generator (CAG) is operated with the principal of thermal liquid evaporation through heating of e-liquid in the initial phase, followed by nucleation and condensation regulated through a mixture of airflow to generate aerosols, such as in an electronic cigarette (EC). The CAG is particularly useful in generating aerosols of large volumes in a continuous manner, for instances such as in vivo inhalation toxicology studies, where usage of ECs is not feasible. The thermal effects of generating aerosol from the CAG are similar in terms of temperature applied in an EC, thus allowing investigators to assess the vapors of e-liquids at scale and reproducibility. As the operation of the CAG allows users to control critical parameters such as the flow rate of e-liquid, heating temperatures and dilution air flows, it allows investigators to test various e-liquid formulations in a well-controlled device. Properties, such as aerosol particle size, are demonstrated to be regulated with the air flow rate with respect to the e-liquid flow and e-liquid composition. The CAG, however, is limited in assessing common EC-related issues, such as overheating of its elements. We seek to demonstrate that the CAG can generate aerosol that is reproducible and continuous, by assessing the chemical and physical aerosol characteristics with a chosen e-liquid formulation. The protocol describes the operating parameters of liquid flow rate, dilution air-flow rates and operating procedures needing to optimize the aerosol concentration and particle size required for an in vivo toxicology study. Presenting the representative results from the protocol and discussing the challenges and applications of working with a CAG, we demonstrate that CAG can be used in a reproducible fashion. The technology and protocol, that has been developed from prior work, serve as a foundation for future innovations for laboratory-controlled aerosol generation investigations.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Aerossóis , Tamanho da Partícula , Reprodutibilidade dos Testes , Veias
2.
J Appl Toxicol ; 41(10): 1598-1619, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33825214

RESUMO

Cigarette smoking is one major modifiable risk factor in the development and progression of chronic obstructive pulmonary disease and cardiovascular disease. To characterize and compare cigarette smoke (CS)-induced disease endpoints after exposure in either whole-body (WB) or nose-only (NO) exposure systems, we exposed apolipoprotein E-deficient mice to filtered air (Sham) or to the same total particulate matter (TPM) concentration of mainstream smoke from 3R4F reference cigarettes in NO or WB exposure chambers (EC) for 2 months. At matching TPM concentrations, we observed similar concentrations of carbon monoxide, acetaldehyde, and acrolein, but higher concentrations of nicotine and formaldehyde in NOEC than in WBEC. In both exposure systems, CS exposure led to the expected adaptive changes in nasal epithelia, altered lung function, lung inflammation, and pronounced changes in the nasal epithelial transcriptome and lung proteome. Exposure in the NOEC caused generally more severe histopathological changes in the nasal epithelia and a higher stress response as indicated by body weight decrease and lower blood lymphocyte counts compared with WB exposed mice. Erythropoiesis, and increases in total plasma triglyceride levels and atherosclerotic plaque area were observed only in CS-exposed mice in the WBEC group but not in the NOEC group. Although the composition of CS in the breathing zone is not completely comparable in the two exposure systems, the CS-induced respiratory disease endpoints were largely confirmed in both systems, with a higher magnitude of severity after NO exposure. CS-accelerated atherosclerosis and other pro-atherosclerotic factors were only significant in WBEC.


Assuntos
Absorção Fisiológica , Apolipoproteínas/efeitos dos fármacos , Apolipoproteínas/metabolismo , Doenças Cardiovasculares/induzido quimicamente , Fumar Cigarros/efeitos adversos , Exposição por Inalação , Pneumopatias/induzido quimicamente , Fumaça/efeitos adversos , Animais , Doenças Cardiovasculares/fisiopatologia , Modelos Animais de Doenças , Pneumopatias/fisiopatologia , Masculino , Camundongos
3.
Anat Rec (Hoboken) ; 304(9): 2050-2067, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33554477

RESUMO

Aerosol dosimetry estimates for mouse strains used as models for human disease are not available, primarily because of the lack of tracheobronchial airway morphometry data. By using micro-CT scans of in-situ prepared lung casts, tracheobronchial airway morphometry for four strains of mice were obtained: Balb/c, AJ, C57BL/6, and Apoe-/- . The automated tracheobronchial airway morphometry algorithms for airway length and diameter were successfully verified against previously published manual and automated tracheobronchial airway morphometry data derived from two identical in-situ Balb/c mouse lung casts. There was also excellent agreement in tracheobronchial airway length and diameter between the automated and manual airway data for the AJ, C57BL/6, and Apoe-/- mice. Differences in branch angle measurements were partially due to the differences in definition between the automated algorithms and manual morphometry techniques. Unlike the manual airway morphometry techniques, the automated algorithms were able to provide a value for inclination to gravity for each airway. Inclusion of an inclination to gravity angle for each airway along with airway length, diameter, and branch angle make the current automated tracheobronchial airway data suitable for use in dosimetry programs that can provide dosimetry estimates for inhaled material. The significant differences in upper tracheobronchial airways between Balb/c mice and between C57BL/6 and Apoe-/- mice highlight the need for mouse strain-specific aerosol dosimetry estimates.


Assuntos
Exposição por Inalação , Traqueia , Aerossóis , Animais , Apolipoproteínas E , Modelos Animais de Doenças , Camundongos , Camundongos Endogâmicos C57BL , Traqueia/diagnóstico por imagem , Microtomografia por Raio-X
4.
Toxicol In Vitro ; 67: 104870, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32330563

RESUMO

Accurately determining the delivered dose is critical to understanding biological response due to cell exposure to chemical constituents in aerosols. Deposition efficiency and uniformity of deposition was measured experimentally using monodisperse solid fluorescent particles with mass median aerodynamic diameters (MMAD) of 0.51, 1.1, 2.2 and 3.3 µm in the Vitrocell® AMES 48 air-liquid-interface (ALI) in vitro exposure system. Experimental results were compared with computational fluid dynamic, (CFD; using both Lagrangian and Eulerian approaches) predicted deposition efficiency and uniformity for a single row (N = 6) of petri dishes in the Vitrocell® AMES 48 system. The average experimentally measured deposition efficiency ranged from 0.007% to 0.43% for 0.51-3.3 µm MMAD particles, respectively. There was good agreement between average experimentally measured and the CFD predicted particle deposition efficiency, regardless of approach. Experimentally measured and CFD predicted average uniformity of deposition was greater than 45% of the mean for all particle diameters. During this work a new design was introduced by the manufacturer and evaluated using Lagragian CFD. Lagragian CFD predictions showed better uniformity of deposition, but reduced deposition efficiency with the new design. Deposition efficiency and variability in particle deposition across petri dishes for solid particles should be considered when designing exposure regimens using the Vitrocell® AMES 48 ALI in vitro exposure system.


Assuntos
Técnicas de Cultura de Células/instrumentação , Hidrodinâmica , Aerossóis , Ar , Material Particulado
5.
Chem Res Toxicol ; 33(2): 505-514, 2020 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-31909610

RESUMO

Chemical and physical characterization of transported evolving aerosols in an in vitro system is complex. The challenges include appropriate sampling sensitivity, measurement capabilities, and performing online measurements of constituents in the flowing aerosol during exposure. We assessed the performance of single-photon ionization mass spectrometry in measuring aerosol properties within an in vitro aerosol exposure system. The sampling efficiency of the instrument was studied under three protocols to capture the evolving aerosol process inside the exposure system, and it was evaluated using computational fluid dynamics modeling. The changes in the aerosol as dilution is applied show not only a reduction in concentration of the traced substances but also selective sampling due to evolution of the aerosol and (gas/liquid) phase partitioning of the substances forming the aerosol or a change in the aerosol properties. These effects have potentially a direct impact on the delivered dose, as aerosol deposition is dependent on particle size. Dilution affects the chemical concentration of the substances as well as the interconnected physical properties of the aerosol; therefore, the experimental design of in vitro studies should not only report the dilution flow rates but also details of the applied dilution protocol. This adds a layer of complexity to the design and comparison of studies. We also discuss the potential and limitations of single-photon ionization mass spectrometry as a tool in in vitro monitoring of aerosols.


Assuntos
Aerossóis/administração & dosagem , Aerossóis/análise , Exposição Ambiental/análise , Monitoramento Ambiental , Fótons , Espectrometria de Massas , Tamanho da Partícula
6.
Biomed Res Int ; 2018: 9141746, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29992167

RESUMO

BACKGROUND AND OBJECTIVES: Breast-conserving surgery represents the standard of care for the treatment of small breast cancers. However, there is a population of patients who cannot undergo the standard surgical procedures due to several reasons such as age, performance status, or comorbidity. Our aim was to investigate the feasibility and safety of percutaneous US-guided laser ablation for unresectable unifocal breast cancer (BC). METHODS: Between December 2012 and March 2017, 12 consecutive patients underwent percutaneous US-guided laser ablation as radical treatment of primary inoperable unifocal BC. RESULTS: At median follow-up of 28.5 months (range 6-51), no residual disease or progression occurred; the overall success rate for complete tumor ablation was therefore 100%. No significant operative side effects were observed, with only 2 (13.3%) experiencing slight to mild pain during the procedure, and all patients complained of a mild dull aching pain in the first week after procedure. CONCLUSIONS: Laser ablation promises to be a safe and feasible approach in those patients who are not eligible to the standard surgical approach. However, longer follow-up results and larger studies are strongly needed.


Assuntos
Neoplasias da Mama/terapia , Terapia a Laser , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Feminino , Humanos , Itália , Recidiva Local de Neoplasia , Projetos Piloto , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção