Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
ACS Nano ; 18(3): 1982-1994, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38194518

RESUMO

Sophisticated thin film growth techniques increasingly rely on the addition of a plasma component to open or widen a processing window, particularly at low temperatures. Taking advantage of continued increases in accelerator-based X-ray source brilliance, this real-time study uses X-ray Photon Correlation Spectroscopy (XPCS) to elucidate the nanoscale surface dynamics during Plasma-Enhanced Atomic Layer Deposition (PE-ALD) of an epitaxial indium nitride film. Ultrathin films are synthesized from repeated cycles of alternating self-limited surface reactions induced by temporally separated pulses of the material precursor and plasma reactant, allowing the influence of each on the evolving morphology to be examined. During the heteroepitaxial 3D growth examined here, sudden changes in the surface structure during initial film growth, consistent with numerous overlapping stress-relief events, are observed. When the film becomes continuous, the nanoscale surface morphology abruptly becomes long-lived with a correlation time spanning the period of the experiment. Throughout the growth experiment, there is a consistent repeating pattern of correlations associated with the cyclic growth process, which is modeled as transitions between different surface states. The plasma exposure does not simply freeze in a structure that is then built upon in subsequent cycles, but rather, there is considerable surface evolution during all phases of the growth cycle.

2.
Case Rep Med ; 2023: 9528088, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37128220

RESUMO

Ovarian vein thrombosis (OVT) is a rare thromboembolic condition. It involves the right ovarian vein in 70-80% of cases. The risk factors for the development of OVT are pregnancy or puerperium, hormone therapy with estrogen, recent surgery or hospitalization, malignancy, pelvic inflammatory diseases, thrombophilia and idiopathic OVT. We present a rare case of left OVT in a young, non-pregnant woman in her 30 s. A high degree of suspicion is necessitated in patients with the triad of young-middle-aged female, pain abdomen in lower quadrant and hematuria to diagnose OVT. Contrast enhanced computer tomography (CT-venography) is the diagnostic modality of choice. The patient was initially treated with low molecular weight heparin and then switched to direct oral anticoagulants. At 6-monthsfollow-up the patient was free from any symptoms.

3.
J Vasc Surg ; 77(5): 1553-1561.e2, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36272506

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has been the favored approach for the treatment of type B aortic dissection (TBAD). To obtain an adequate proximal landing zone, coverage of the left subclavian artery (LSA) will often be necessary. The occurrence of possible neurologic complications has continued to be debated. We investigated the management of the LSA in patients with TBAD undergoing endovascular repair. METHODS: We searched the PubMed and MEDLINE databases to October 2020 for studies of TEVAR for TBAD. Data on the study design, demographics, endograft details, LSA coverage and revascularization, mortality, complications, and follow-up were extracted and analyzed. The effects of LSA coverage and revascularization on neurologic complications and outcomes were investigated. RESULTS: A total of 26 reports (24 retrospective and 2 prospective) were deemed eligible for our study. A total of 1483 patients (mean age, 56.9 ± 6.2 years) had undergone TEVAR for acute (n = 932; 62.9%), subacute (n = 36; 2.4%), or chronic (n = 515; 34.7%) TBAD, with a success rate of 97.8% and hospital mortality of 4.9%. The LSA origin had been covered for 707 patients (47.7%), and 326 had undergone LSA revascularization (surgical, n = 96; endovascular, n = 170; unspecified or not reported, n = 60). LSA revascularization was concomitant for 68.1% of cases, after TEVAR for 1.8%, and not reported for 30.1%. Of 1146 patients, 10 (0.9%) had experienced left arm claudication, and the overall stroke rate was 3.3% (2.7% for the LSA group and 1% for the uncovered LSA group; P = .0815). Of the patients with stroke and a covered LSA, 1% (2 of 203) had undergone LSA revascularization and 4.8% (5 of 105) had not (P = .0478). Twenty-six patients (1.9%) had developed paraplegia: 0.7% (3 of 433) with a covered LSA, 1.4% (7 of 491) with an uncovered LSA (P = .3508), and not reported for 16 patients. Endoleak was present in 138 patients (13.4%) at a mean follow-up of 32.1 ± 25.6 months. CONCLUSIONS: Our review has shown that LSA coverage during endovascular repair for complicated TBAD will does not significantly increase the risk of neurologic complications; however, revascularization of the LSA should be always recommended.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Pessoa de Meia-Idade , Prótese Vascular , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Stents , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia
4.
Pediatr Diabetes ; 23(1): 64-72, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779099

RESUMO

BACKGROUND: Treatment of patients with type 1 diabetes requires experience and a specific infrastructure. Therefore, center size might influence outcome in diabetes treatment. OBJECTIVE: To analyze the influence of center size on the quality of diabetes treatment in children and adolescents in Germany and Austria. PATIENTS AND METHODS: In 2009 and 2018, we analyzed metabolic control, acute complications, and rates of recommended screening tests in the DPV cohort. Diabetes centers were classified according to the number of patients from "XS" to "XL" (<20 [XS], ≥20 to <50 [S], ≥50 to <100 [M], ≥100 to <200 [L], ≥200 [XL]). RESULTS: Over the 10-year period, metabolic control improved significantly in "M", "L" and "XL" diabetes centers. Treatment targets are best achieved in "M" centers, while "XS" centers have the highest mean hemoglobin A1c. The relation between hemoglobin A1c and center size follows a "v-shaped" curve. In 2009, conventional insulin therapy was most frequently used in "XS" centers, but in 2018, there was no difference in mode of insulin therapy according to center size. Use of CSII and sensor augmented CSII/hybrid closed loop increased with center size. Patients cared for in "XS" diabetes centers had the fewest follow-up visits per year. The rates of severe hypoglycemia and DKA were lowest in "XL" diabetes centers, and the rate of DKA was highest in "XS" centers. CONCLUSION: Center size influences quality of care in pediatric patients with type 1 diabetes. Further investigations regarding contributing factors such as staffing and financial resources are required.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Instalações de Saúde/classificação , Qualidade da Assistência à Saúde/normas , Adolescente , Áustria/epidemiologia , Criança , Estudos de Coortes , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Alemanha/epidemiologia , Instalações de Saúde/normas , Instalações de Saúde/estatística & dados numéricos , Humanos , Estudos Longitudinais , Masculino , Qualidade da Assistência à Saúde/estatística & dados numéricos
5.
Microsyst Nanoeng ; 7: 10, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34567727

RESUMO

The structural and functional maturation of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is essential for pharmaceutical testing, disease modeling, and ultimately therapeutic use. Multicellular 3D-tissue platforms have improved the functional maturation of hiPSC-CMs, but probing cardiac contractile properties in a 3D environment remains challenging, especially at depth and in live tissues. Using small-angle X-ray scattering (SAXS) imaging, we show that hiPSC-CMs matured and examined in a 3D environment exhibit a periodic spatial arrangement of the myofilament lattice, which has not been previously detected in hiPSC-CMs. The contractile force is found to correlate with both the scattering intensity (R 2 = 0.44) and lattice spacing (R 2 = 0.46). The scattering intensity also correlates with lattice spacing (R 2 = 0.81), suggestive of lower noise in our structural measurement than in the functional measurement. Notably, we observed decreased myofilament ordering in tissues with a myofilament mutation known to lead to hypertrophic cardiomyopathy (HCM). Our results highlight the progress of human cardiac tissue engineering and enable unprecedented study of structural maturation in hiPSC-CMs.

6.
Interact Cardiovasc Thorac Surg ; 33(5): 746-754, 2021 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-34056647

RESUMO

OBJECTIVES: Surgical repair of aortic dissection involving the proximal aortic arch is associated with higher morbidity and mortality, in particular when elderly high-risk patients are concerned. Endovascular treatments for this disease are under evaluation and some reports exist. We investigated the current use of catheter-based treatments for the dissected proximal aortic arch repair. METHODS: We searched in PubMed and MEDLINE databases up to the end of June 2020 for studies on endovascular treatment of the dissected proximal aortic arch. Data on demographic, procedure and stent graft (SG) details, access route, mortality with cause of death, complications and follow-up were extracted. A systematic review on the employed technology, procedure and outcome was performed. RESULTS: A total number of 15 articles (13 retrospective reports and 2 case reports) were deemed eligible and were included in the study. In total, 140 patients (mean age: 56.7 years in 106 cases) received endovascular treatments for the dissected proximal aortic arch (unspecific aortic dissection: 14; acute and subacute type A aortic dissection: 88; chronic type A aortic dissection: 23; type B aortic dissection with retrograde type A dissection: 15). The procedure strategy included unspecific thoracic endovascular aorta repair (TEVAR) (n = 8), TEVAR + supra-aortic debranching (n = 2), TEVAR + cervical bypass (n = 8), TEVAR + periscope SG (n = 12), TEVAR + chimney graft (n = 8), TEVAR + branched SG (n = 21) and TEVAR + fenestration (n = 81). Procedural success rate was 95.6% for 116 reported cases. Complications included endoleaks (postoperative: 2; late: 5), stroke (n = 4), late SG-induced new entry (n = 3) and new false lumen formation (n = 1). Hospital mortality was 5% (6 cases) in 13 reports (120 patients). The mean follow-up time was 26.2 ± 29.4 months and 2 patients died during follow-up. CONCLUSIONS: As an alternative to surgery for high-risk patients with a dissected proximal aortic arch, the endovascular treatment seems to be promising in highly selected cases. Further studies with long-term results and specifically designed devices are required to standardize this approach.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
7.
J Cardiothorac Surg ; 16(1): 114, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33902666

RESUMO

OBJECTIVES: Determine if shortening the covered section of a self-expanding bidirectional arterial cannula, can enhance retrograde flow and thus reduce the risk of lower limb ischemia. METHODS: Outlet pressure vs flow rate was determined for three cannulas types: a 15F self-expanding bidirectional cannula having a covered section of 90 mm, the same cannula but with a shorter covered section of 60 mm, and a Biomedicus cannula as control. The performances of all the cannulas were compared using a computerized flow-bench with calibrated sensors and a centrifugal pump. Water retrograde flow was determined using a tank timer technique. Anterograde and retrograde flow rate versus outlet pressure were determined at six different pump speed. RESULTS: For each of the six pump speed, both bidirectional cannulas, 60-mm covered and 90-mm covered respectively, showed higher performance than Biomedicus cannula control, as demonstrated by higher flow rate and lower pressure. We also observed that for the bidirectional cannula with shorter covered section, i.e. 60 mm coverage, provides enhanced performance as compared to a 90-mm coverage. Finally, the flow rate and the corresponding pressure can be consistently measured by our experimental set-up with low variability. CONCLUSIONS: The new configuration of a shorter covered section in a bidirectional self-expanding cannula design, may present an opportunity to overcome lower leg ischemia during extra-corporal life support with long term peripheral cannulation.


Assuntos
Cânula , Desenho de Equipamento , Isquemia/prevenção & controle , Perfusão/instrumentação , Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Humanos , Isquemia/etiologia , Perna (Membro)/irrigação sanguínea
8.
Phys Rev Lett ; 126(1): 016101, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33480781

RESUMO

Investigating the relationship between structure and dynamical processes is a central goal in condensed matter physics. Perhaps the most noted relationship between the two is the phenomenon of de Gennes narrowing, in which relaxation times in liquids are proportional to the scattering structure factor. Here, a similar relationship is discovered during the self-organized ion-beam nanopatterning of silicon using coherent x-ray scattering. However, in contrast to the exponential relaxation of fluctuations in classic de Gennes narrowing, the dynamic surface exhibits a wide range of behaviors as a function of the length scale, with a compressed exponential relaxation at lengths corresponding to the dominant structural motif-self-organized nanoscale ripples. These behaviors are reproduced in simulations of a nonlinear model describing the surface evolution. We suggest that the compressed exponential behavior observed here is due to the morphological persistence of the self-organized surface ripple patterns which form and evolve during ion-beam nanopatterning.

9.
Interact Cardiovasc Thorac Surg ; 32(3): 408-416, 2021 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-33351896

RESUMO

OBJECTIVES: Transcatheter aortic root repair (TARR) consists of the simultaneous endovascular replacement of the aortic valve, the root and the proximal ascending aorta. The aim of the study is to set-up a computational model of TARR to explore the impact of the endovascular procedure on the coronary circulation supported by chimney grafts. METHODS: Computed tomography of a patient with dilated ascending aorta was segmented to obtain a 3-dimensional representation of the proximal thoracic aorta, including aortic root and supra-aortic branches. Computed assisted design tools were used to modify the geometry to create the post-procedural TARR configuration featuring the main aortic endograft integrated with 2 chimney grafts for coronary circulation. Computational Fluid Dynamics simulations were run in both pre- and post-procedural configurations using a pulsatile inflow and lumped parameter models at the outflows to simulate peripheral aortic and coronary circulation. Differences in coronary flow and pressure along the cardiac cycle were evaluated. RESULTS: After the virtual implant of the TARR device with coronary grafts, the flow became more organized and less recirculation was seen in the ascending aorta. Coronary perfusion was guaranteed with negligible flow differences between pre- and post-procedural configurations. However, despite being well perfused by chimney grafts, the procedure induces an increase of the pressure drop between the coronary ostia and the ascending aorta of 8 mmHg. CONCLUSIONS: The proposed numerical simulations, in the specific case under investigation, suggest that the TARR technique maintains coronary perfusion through the chimney grafts. This study calls for experimental validation and further analyses of the impact of TARR on cardiac afterload, decrease of aortic compliance and local pressure drop induced by the coronary chimney grafts.


Assuntos
Aorta/fisiopatologia , Aorta/cirurgia , Prótese Vascular , Circulação Coronária , Hidrodinâmica , Substituição da Valva Aórtica Transcateter , Aorta/diagnóstico por imagem , Simulação por Computador , Humanos , Imageamento Tridimensional , Pressão , Desenho de Prótese , Tomografia Computadorizada por Raios X
10.
Eur J Cardiothorac Surg ; 59(1): 80-91, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-32893292

RESUMO

OBJECTIVES: Type A aortic dissection requires immediate surgical repair. Despite improvements in surgery and anaesthesia, there is still a considerable risk when high-risk patients are concerned. Less invasive endovascular treatments are under evaluation. We investigated the current status of catheter-based treatment for type A aortic dissection with the entry tear located in the ascending aorta. METHODS: A PubMed search was supplemented by searching through bibliographies and key articles. Demographics, risk score, stent graft detail, access route, mortality, cause of death, complications, reinterventions and follow-up data were extracted and analysed. RESULTS: Thirty-one articles (7 retrospective reports; 24 case reports/series) were included in the study. In total, 104 patients (mean age 71 ± 14 years) received endovascular treatment for acute (63) or chronic (41) type A dissection. A history of a major cardiac or aortic operation was present in 29 patients. The mean EuroSCORE II was 30 ± 20 in 4 reports. A total of 114 stent grafts were implanted: 'off-the-shelf', 65/114; custom made, 12/114; and modified, 7/114. Hospital complications included intraprocedural conversion to open surgery (2/104), stroke (2/104), coronary stenting (2/104), early endoleak (9/104) and repeat aortic endovascular treatment for endoleak (5/104). Hospital mortality was 10% (intraoperative death 2/104). Mean duration of follow-up time was 21 ± 21 months (range 1-81 months); follow-up data were available for 86 patients: 10 patients died of non-aortic-related causes; reintervention for aortic disease (endovascular repair or open surgery) was performed in 8 patients. CONCLUSIONS: Catheter-based ascending aorta repair for type A aortic dissection with the entry tear in the ascending aorta can be considered in carefully selected high-risk patients. Further analysis and specifically designed devices are required.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Catéteres , Procedimentos Endovasculares/efeitos adversos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Resultado do Tratamento
11.
J Cardiothorac Surg ; 15(1): 132, 2020 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-32517779

RESUMO

OBJECTIVES: Given the similarities between coronary ostia and renal arteries, chimney grafts (CG) for kidney perfusion during abdominal endovascular aneurysm repair (EVAR) can be considered for coronary perfusion in future transcatheter aortic root repair (TARR) techniques. We analysed the results of renal CG and compared anatomic and technical details with root and coronary anthropometric data. METHODS: Current status of kidney perfusion with CG was reviewed from literature. Anatomic details, technical data, CG performance and clinical outcome were collected and analysed. Anatomic details of aortic landing zone and renal arteries were compared with human anthropometric data of aortic root, ascending aorta and coronary ostia. RESULTS: Seventeen articles reported 430 patients (mean age:74.5 ± 2.9 years) treated with renal CG. Mean length and diameter of proximal landing zone were 2.0 ± 2.0 mm and 26.4 ± 4.3 mm, respectively (anthropometric correspondence: ascending aorta diameter of 29.3 mm). Aortic endograft mean diameter was 26.4 ± 7.3 mm with reported oversize of 19.5 ± 6.0%. In total, 590 renal arteries were treated (left:325; right:265; bilateral:139 cases). Mean left and right renal artery diameters were 5.7 ± 0.6 mm and 5.8 ± 0.7 mm, respectively (anthropometric correspondence: coronary ostia diameters of 4.8 mm (left) and 3.7 mm (right)) with reported CG oversize of 19.75 ± 6% (left) and 18.1 ± 5.1% (right). Mean follow-up time was 16.5 ± 8.5 months, CG occlusion rate was 3.2% and endoleak I or II was reported in 83 patients (19.3%), requiring 7 procedures. CONCLUSIONS: CG provides satisfactory results in patients with suitable renal artery diameter. Based on aortic root and coronary anthropometric data, CG can be considered in future TARR technologies for coronary perfusion but further tests for flow evaluations are mandatory.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Vasos Coronários/patologia , Artéria Renal/cirurgia , Idoso , Aorta/cirurgia , Aortografia , Endoleak , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Perfusão , Desenho de Prótese , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
12.
Interact Cardiovasc Thorac Surg ; 31(1): 121-128, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32303058

RESUMO

OBJECTIVES: Transcatheter aortic root repair is still not available because of the technical challenge of coronary perfusion. The use of chimney grafts for coronary ostia can be an option and we tested the flow-through coronary chimney grafts deployed in a 3-dimensional-printed root model as part of a transcatheter aortic root repair system. METHODS: A 3-dimensional-printed root was used to test the coronary flow after the deployment of 1 root endograft (28 mm diameter) and two 6-mm diameter 10-cm long coronary chimney grafts. Continuous coronary flows were measured in a bench test at different pressure levels (60, 80 and 100 mmHg) and compared to target coronary flows (250 ml/min at rest for the left and 150 ml/min at rest for the right coronary artery). RESULTS: The computed tomography scan-based root was modified with two 5-mm diameter coronary conduits to overcome the limits of the original 3-dimensional-printed coronary ostia. The root was placed in the hydrodynamic system: adjusted coronary free flow at 60, 80 and 100 mmHg of pressure was 1913, 2200 and 2480 ml/min for left coronary and 1633, 2026 and 2366 ml/min for right coronary, respectively. After endografts deployment, mean chimney graft flow at 60, 80 and 100 mmHg of pressure was 1053 ml/min (-45%), 1306 ml/min (-41%) and 1502 ml/min (-40%) for the left coronary and 1100 ml/min (-33%), 1460 ml/min (-28%) and 1626 ml/min (-31%) for the right coronary, respectively. CONCLUSIONS: In this preliminary study, chimney grafts for transcatheter aortic root repair provided 830% of target flow in the right coronary (-31% of free flow) and 414% of target flow in the left coronary (-42% of free flow) which is more than sufficient for both coronaries in real-life conditions. The potential of this approach should be further explored with specifically designed endografts.


Assuntos
Valva Aórtica/cirurgia , Transposição das Grandes Artérias/métodos , Implante de Prótese Vascular/métodos , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Procedimentos Endovasculares/métodos , Transposição dos Grandes Vasos/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Reoperação , Stents , Fatores de Tempo , Transposição dos Grandes Vasos/fisiopatologia , Resultado do Tratamento
14.
Perfusion ; 35(5): 393-396, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31696777

RESUMO

AIM: This study was designed to quantify the influence of blood as test medium compared to water in cannula bench performance assessment. METHODS: An in vitro circuit was set-up with silicone tubing between two reservoirs. The test medium was pumped from the lower reservoir by centrifugal pump to the upper reservoir. The test-cannula was inserted in a silicone tube connected between the lower reservoir and the centrifugal pump. Flow rate and pump inlet-pressure were measured for wall-less versus thin-wall cannula using a centrifugal pump in a dynamic bench-test for an afterload of 40-60 mmHg using two media: blood 10 g/dL and 5.6 g/dL and water 0 g/dL. RESULTS: The wall-less cannula showed significantly higher flows rates as compared to the thin-wall cannula (control), with both hemoglobin concentrations and water. Indeed, for a target volume of 200-250 mL of blood (Hg 10 g/dL) in the upper reservoir, the cannula outlet pressure (P) was -14 ± 14 mmHg versus -18 ± 11 mmHg for the wall-less and control respectively; the cannula outlet flow rate (Q) was 3.91 ± 0.41 versus 3.67 ± 0.45 L/min, respectively. At the same target volume but with a Hg of 5.7 g/dL, P was -16 ± 12 mmHg versus -19 ± 12 mmHg and Q was 4 ± 0.1 versus 4 ± 0.4 L/min for the wall-less cannula and control respectively. Likewise, P and Q values with water were -1 mmHg versus -0.67 ± 0.58 mmHg and 4.17 ± 0.45 L/min versus 4.08 ± 0.47 L/min for the wall-less and control respectively. CONCLUSION: Walls-less cannula showed 5.6% less pump inlet-pressure differences calculated between blood and water, as compared to that of thin-wall cannula (-21 times). Flow differences were 6% and 10% for the walls-less and thin-wall cannula respectively. We conclude that testing the cannula performance with water is a good scenario and can overestimate the flow by a 10%. However, superiority for wall-less is preserved with both water and blood.


Assuntos
Viscosidade Sanguínea/imunologia , Cânula/normas , Veias/fisiologia , Humanos
15.
Interact Cardiovasc Thorac Surg ; 30(2): 203-214, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31633170

RESUMO

Three-dimensional (3D)-printing technologies in cardiovascular surgery have provided a new way to tailor surgical and percutaneous treatments. Digital information from standard cardiac imaging is integrated into physical 3D models for an accurate spatial visualization of anatomical details. We reviewed the available literature and analysed the different printing technologies, the required procedural steps for 3D prototyping, the used cardiac imaging, the available materials and the clinical implications. We have highlighted different materials used to replicate aortic and mitral valves, vessels and myocardial properties. 3D printing allows a heuristic approach to investigate complex cardiovascular diseases, and it is a unique patient-specific technology providing enhanced understanding and tactile representation of cardiovascular anatomies for the procedural planning and decision-making process. 3D printing may also be used for medical education and surgical/transcatheter training. Communication between doctors and patients can also benefit from 3D models by improving the patient understanding of pathologies. Furthermore, medical device development and testing can be performed with rapid 3D prototyping. Additionally, widespread application of 3D printing in the cardiovascular field combined with tissue engineering will pave the way to 3D-bioprinted tissues for regenerative medicinal applications and 3D-printed organs.


Assuntos
Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valvas Cardíacas/cirurgia , Invenções , Impressão Tridimensional , Humanos , Modelos Anatômicos
16.
Interact Cardiovasc Thorac Surg ; 29(5): 793-799, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31369123

RESUMO

OBJECTIVES: Available apical occluders do not fulfil requirements for full-percutaneous transapical valve procedures with large-sized introducer sheaths. A self-expanding closure device designed for closed-chest transapical valve procedures was tested in an animal model to verify safety, efficacy and thrombogenicity. METHODS: Large-sized 21-Fr introducer sheaths (Certitude™ system for Sapien™ valves) were percutaneously placed in the ventricles of nine 3-month old minipigs. To seal the apical access, delivery catheters carrying folded self-expanding plugs were inserted. Then, the plugs were deployed while sheaths were removed. Echocardiograms verified tamponade and cardiac function, drains were not placed and a 3-month long aspirin therapy was administered. After 6 and 9 months, animals were euthanized and organs were analysed for macroembolic lesions search. Histological analysis was also performed. RESULTS: Nine minipigs (weight: 28±3 kg) were used for this study. Eight plugs were successfully deployed in 8 ventricles without cardiac tamponade or ventricular dysfunction (success rate: 88.9%). In a failed procedure (the animal died after 1 month of cardiac tamponade), the outer disc of the apical plug got stuck in the intercostal space and did not correctly deploy. Post-mortem analysis in 8 minipigs at 6 (n = 4) and 9 months (n = 4) confirmed full deployment and good fixation of all plugs with internal surfaces covered by new endocardium. Macroscopic analysis of myocardium and vital organs showed absence of embolic lesions. Histological analysis showed absence of significant inflammatory infiltration and thrombosis. CONCLUSIONS: In this animal model, self-expanding closure devices sealed 21-Fr large percutaneous apical accesses without acute tamponade, thrombosis or embolization. Further tests to evaluate full-percutaneous closed-chest apical procedures are required.


Assuntos
Cateterismo Cardíaco/instrumentação , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Ventrículos do Coração/cirurgia , Animais , Modelos Animais de Doenças , Suínos , Porco Miniatura
17.
Nat Commun ; 10(1): 2638, 2019 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-31201329

RESUMO

The properties of artificially grown thin films are strongly affected by surface processes during growth. Coherent X-rays provide an approach to better understand such processes and fluctuations far from equilibrium. Here we report results for vacuum deposition of C60 on a graphene-coated surface investigated with X-ray Photon Correlation Spectroscopy in surface-sensitive conditions. Step-flow is observed through measurement of the step-edge velocity in the late stages of growth after crystalline mounds have formed. We show that the step-edge velocity is coupled to the terrace length, and that there is a variation in the velocity from larger step spacing at the center of crystalline mounds to closely-spaced, more slowly propagating steps at their edges. The results extend theories of surface growth, since the behavior is consistent with surface evolution driven by processes that include surface diffusion, the motion of step-edges, and attachment at step edges with significant step-edge barriers.

18.
ASAIO J ; 65(8): 874-881, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30325848

RESUMO

Transcatheter aortic root repair (TARR) is still not available because of the complex anatomy. In order to develop future TARR technologies, a human-derived bench test model is required before performing animal tests. For this purpose, we aimed to validate computed tomography (CT)-derived 3D-printed root models for TARR technologies. Four human CT-derived roots were printed using different resins: Visijet M3 Crystal, Photopolymer gel SUP705, Formlabs flexible resin, and Materialise HeartPrint Flex. A stress test was performed using a 26-mm balloon-expandable Sapien valve deployed in aortic position. The too rigid Visijet M3 Crystal was not tested. Among the others, all but one (HeartPrint Flex, Materialise, Leuven, Belgium) ruptured during the test showing low wall resistances. Further tests were then performed in two roots made of HeartPrint Flex resin. The anatomic validation was performed comparing human CT scan-derived 3D reconstructions and CT scan measurements: a mean difference of 0.57 ± 0.4 mm for aortic annulus diameter and for the distance between the aortic annulus and the coronary ostia was measured. Concerning the coronary arteries, they are of paramount importance for new TARR technologies, and therefore, we tested the coronary flows of the HeartPrint Flex root at different pressure levels. At 60 mm Hg, right and left mean adjusted coronary flows were 471 and 663 ml/min; at 80 mm Hg, right and left mean coronary flows were 551 and 777 ml/min; and at 100 mm Hg, right and left mean coronary flows were 625 and 858 ml/min. In our study, 3D-printed root models correlate well with human anatomy and guarantee physiologic coronary flows for TARR technologies.


Assuntos
Modelos Anatômicos , Impressão Tridimensional , Substituição da Valva Aórtica Transcateter/métodos , Humanos
19.
J Phys Condens Matter ; 30(29): 294004, 2018 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-29757159

RESUMO

Linear-regime Ar+ bombardment of Si produces symmetrical ripple structures at ion incidence angles above 45° measured off-normal (Madi 2009 J. Phys.: Condens. Matter 21). In the nonlinear regime, new behaviors emerge. In this paper, we present experimental results of ion bombardment that continues into the nonlinear regime until pattern saturation at multiple ion incidence angles, showing the evolution of their grazing incidence small-angle x-ray scattering (GISAXS) spectra as well as atomic force microscopy topographs of the final, saturated structures. Asymmetric structures emerge parallel to the direction of the projected ion beam on the sample surface, constituting a height asymmetry not found in the linear regime. We then present simulations of surface height evolution under ion bombardment using a nonlinear partial differential equation developed by Pearson and Bradley (2015 J. Phys.: Condens. Matter 27 015010). We present simulated GISAXS spectra from these simulations, as well as simulated scattering from a sawtooth structure using the FitGISAXS software package (Babonneau 2010 J. Appl. Crystallogr. 43 929-36), and compare the simulated spectra to those observed experimentally. We find that these simulations reproduce many features of the sawtooth structures, as well as the nearly-flat final GISAXS spectra observed experimentally perpendicular to the sawtooth structures. However, the model fails to reproduce the final GISAXS spectra observed parallel to the sawtooth structures.

20.
Interact Cardiovasc Thorac Surg ; 26(6): 1002-1008, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29415164

RESUMO

OBJECTIVES: To treat aortic valve disease and concomitant root disease with transcatheter techniques, 'composite graft' implants are required. Our goal was to assess the suitability of the porcine aortic root for transcatheter root repair tests. METHODS: Eight pig hearts explanted from domestic pigs used in experimental surgery were compared to data from the literature on human hearts. The measured diameters included those of the annulus, sinuses of Valsalva, coronary ostia, sinotubular junction, ascending aorta, innominate artery and aortic arch. The measured distances were from the coronary ostia to the nadir of the corresponding annulus; from the innominate artery to the nadir of the corresponding annulus; from the small curvature of the arch to the nadir of the corresponding annulus. RESULTS: The mean weight of the pigs was 89 ± 5.4 kg. The mean aortic annulus diameter was 20 ± 1.2 mm (human: 23.0 ± 2.5 mm), the sinus of Valsalva diameter was 20.5 ± 0.5 mm (human: 31.4 ± 3.4 mm) and the sinotubular junction diameter was 20 ± 0.9 mm (human: 27.2 ± 3.0 mm). The diameter of the mean ascending aorta was 19 ± 0.7 mm (human: 29.3 ± 4 mm); the diameter of the innominate artery was 8.5 ± 0.7 mm, that of the aortic arch was 15 ± 0.7 mm and that of the coronary ostia was 5 ± 0.5 mm (left) and 4.7 ± 0.5 mm (right) (human: 4.8 ± 0.5 mm and 3.7 ± 0.9 mm). The distances from the left and right coronary orifices to the corresponding annuli were 8 ± 1.5 mm and 14 ± 2.4 mm, respectively (human: 14.7 ± 1.3 mm; 15.4 ± 1.7 mm). The distances from the innominate artery to the nadirs of the left and right coronary annuli were 44 ± 4.3 mm and 41 ± 4 mm (human: 80 ± 17 mm). The distance from the curvature of the small arch to the annulus was 35 ± 4.9 mm. CONCLUSIONS: The porcine heart can be used as an experimental model to design and test new devices for catheter-based composite repair of the aortic root. Nevertheless, caution is required in using devices with tailored dimensions that must be adapted to the smaller pig's root.


Assuntos
Aorta/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Animais , Modelos Animais de Doenças , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...