Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 16(21): 3337-3348, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38738371

RESUMO

Despite the increasing efforts in improving bone health assessments, current diagnostics suffer from critical shortcomings. The present article therefore describes a multiplex label-free immunosensor designed and validated for the assessment of two bone turnover markers (BTMs), namely beta isomerized C-terminal telopeptide of type I collagen (CTx) and Procollagen I Intact N-Terminal (PINP), the combination of which is needed to illustrate an accurate overview of bone health. The immunosensor was then tested outside and inside of a microsystem, with the aim of becoming compatible with a point of care system fabricated for automated assessment of these biomarkers later-on at patient side. Custom-made monoclonal antibodies were specifically designed for this purpose in order to guarantee the selectivity of the immunosensor. In the final platform, a finger prick blood sample is introduced into the microfluidic manifolds without any need for sample preparation step, making the tool suitable for near patient and outside of the central laboratory applications. The platform was exploited in 30 real blood samples with the results validated using electrochemiluminescence immunoassay. The results revealed the platform was capable of measuring the target analyte with high sensitivity and beyond the recommended clinical reference range for each biomarker (CTx: 104-1028 ng L-1 and PINP: 16-96 µg L-1, correspondingly). They also showed the platform to have a limit of detection of 15 (ng L-1) and 0.66 (µg L-1), a limit of quantification of 49 (ng L-1) and 2.21 (µg L-1), and an inter- and intra-assay coefficient of variance of 5.39-6.97% and 6.81-5.37%, for CTx and PINP respectively, which is comparable with the gold standard. The main advantage of the platform over the state-of-the art was the capability of providing the results for two markers recommended for assessing bone health within 15 minutes and without the need for skilled personnel or costly infrastructure.


Assuntos
Biomarcadores , Remodelação Óssea , Colágeno Tipo I , Fragmentos de Peptídeos , Pró-Colágeno , Humanos , Biomarcadores/sangue , Biomarcadores/análise , Pró-Colágeno/sangue , Colágeno Tipo I/sangue , Remodelação Óssea/fisiologia , Fragmentos de Peptídeos/sangue , Imunoensaio/métodos , Peptídeos/sangue , Técnicas Biossensoriais/métodos , Sistemas Automatizados de Assistência Junto ao Leito
2.
Biol Methods Protoc ; 9(1): bpae006, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559752

RESUMO

One of the goals of the HORIZON 2020 project PoCOsteo was to develop a medical device, which would measure and/or quantify proteomic as well as genomic factors as present in whole blood samples collected through finger prick. After validating the tool in the clinical setting, the next step would be its clinical validation based on the existing guidelines. This article presents the protocol of a validation study to be carried out independently at two different centers (Division of Endocrinology and Diabetology at the Medical University of Graz as a clinic-based cohort, and the Endocrinology and Metabolism Research Institute at the Tehran University of Medical Sciences as a population-based cohort). It aims to assess the tool according to the Clinical & Laboratory Standards Institute guidelines, confirming if the proteomics and genomics measurements provided by the tool are accurate and reproducible compared with the existing state-of-the-art tests. This is the first time that such a detailed protocol for lab validation of a medical tool for proteomics and genomic measurement is designed based on the existing guidelines and thus could be used as a template for clinical validation of future point-of-care tools. Moreover, the multicentric cohort design will allow the study of a large number of diverse individuals, which will improve the validity and generalizability of the results for different settings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...