Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
Med Sci Sports Exerc ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597869

RESUMO

INTRODUCTION: Long-term endurance exercise is suspect to elevate the risk of atrial fibrillation (AF),but little is known about cardiovascular outcome and disease progression in this subgroup of AF patients. We investigated whether previous exercise level determines cardiovascular outcome. METHODS: In this post hoc analysis of the RACE 4 randomized trial, we analyzed all patients with a completed questionnaire on sports participation. Three subgroups were made based on lifetime sports hours up to randomization and previous compliance to the international physical activity guidelines. High lifetime hours of high dynamic activity patients were defined as more than 150 min/week of high intense physical exercise. The primary endpoint was a composite of cardiovascular death and hospital admissions. RESULTS: A total of 879 patients were analyzed, divided in 203 high lifetime hours of high dynamic activity -, 192 high lifetime hours of activity- and 484 low lifetime hours of activity patients. Over a mean follow up of 36 months (±14), the primary endpoint occurred in 61 out of 203 (30%) high lifetime hours of high dynamic activity -, 53 out of 192 (27%) high lifetime hours of activity- and 135 out of 484 low lifetime hours of activity patients (28%) (p = 0.74). During follow up 42 high lifetime hours of high dynamic activity- (35%), 43 high lifetime hours of activity- (32%) and 104 low lifetime hours of activity patients (34%) with paroxysmal AF received electrical or chemical cardioversion or atrial ablation (p = 0.90). CONCLUSIONS: In patients included in the RACE 4, there appears to be no relation between previous activity levels and cardiovascular outcome and the need for electrical or chemical cardioversion or atrial ablation. Cardiovascular outcome was driven by AF related arrhythmic events.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38569919

RESUMO

OBJECTIVES: Thoracoscopic hybrid ablation is an effective and safe rhythm control strategy for patients with complex forms of atrial fibrillation. Its effect on left atrial function has not yet been studied. METHODS: In a retrospective single-centre analysis of patients undergoing thoracoscopic hybrid ablation, the left atrial emptying fraction was calculated using the biplane modified Simpson method in the apical 2- and 4-chamber views on transthoracic echocardiography. Left atrial strain (reservoir, conduction and contractility) was quantified using dedicated software. RESULTS: Sixty-seven patients were included (mean age 64 years, long-standing persistent atrial fibrillation in 69%, median atrial fibrillation history duration 64 months). At baseline, left atrial function and contractility were poor. The reservoir and contractile strain improved postprocedure compared to baseline [15 (standard deviation (SD): 8) and 17 (SD: 6); P = 0.013; 3 (SD: 5) and 4 (SD: 4), P = 0.008], whereas the left atrial volume indexed to the body surface area was reduced [51 ml/m2 (SD: 14) and 47 ml/m2 (SD: 18), P = 0.0024]. In patients with preoperative (long-standing) persistent atrial fibrillation and in patients with rhythm restoration, improvements in the emptying fraction, (reservoir and contractile) strain and the left ventricular ejection fraction were observed, whereas the left atrial volume decreased (P < 0.05). CONCLUSIONS: In this cohort of patients with severely diseased left atria, improvement in left atrial contractility and in the emptying fraction after thoracoscopic hybrid ablation for atrial fibrillation in patients with persistent atrial fibrillation is mainly due to rhythm restoration. Interestingly, the procedure itself also results in improved left atrial reservoir strain and reversed left atrial remodelling by reducing left atrial volume.

4.
J Cardiovasc Dev Dis ; 11(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38535099

RESUMO

Identifying electrical dyssynchrony is crucial for cardiac pacing and cardiac resynchronization therapy (CRT). The ultra-high-frequency electrocardiography (UHF-ECG) technique allows instantaneous dyssynchrony analyses with real-time visualization. This review explores the physiological background of higher frequencies in ventricular conduction and the translational evolution of UHF-ECG in cardiac pacing and CRT. Although high-frequency components were studied half a century ago, their exploration in the dyssynchrony context is rare. UHF-ECG records ECG signals from eight precordial leads over multiple beats in time. After initial conceptual studies, the implementation of an instant visualization of ventricular activation led to clinical implementation with minimal patient burden. UHF-ECG aids patient selection in biventricular CRT and evaluates ventricular activation during various forms of conduction system pacing (CSP). UHF-ECG ventricular electrical dyssynchrony has been associated with clinical outcomes in a large retrospective CRT cohort and has been used to study the electrophysiological differences between CSP methods, including His bundle pacing, left bundle branch (area) pacing, left ventricular septal pacing and conventional biventricular pacing. UHF-ECG can potentially be used to determine a tailored resynchronization approach (CRT through biventricular pacing or CSP) based on the electrical substrate (true LBBB vs. non-specified intraventricular conduction delay with more distal left ventricular conduction disease), for the optimization of CRT and holds promise beyond CRT for the risk stratification of ventricular arrhythmias.

6.
Ann Cardiothorac Surg ; 13(1): 54-70, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38380145

RESUMO

In this state-of-the art review on hybrid atrial fibrillation (AF) ablation, we briefly focus on the pathophysiology of AF, the rationale for the hybrid approach, its technical aspects and the efficacy and safety outcomes after hybrid AF ablation, both from meta-analyses and randomized control trial data. Also, we performed a systematic search to provide a provisional overview of real-world hybrid AF ablation efficacy and safety outcomes. Furthermore, we give an insight into the 'Maastricht approach', an approach that allows us to tailor the ablation procedure to the individual patient. Finally, we reflect on future perspectives with the objective to continue improving our thoracoscopic hybrid AF ablation approach. Based on the review of the available literature, we believe it is fair to state that thoracoscopic hybrid AF ablation is a valid alternative to catheter ablation for the treatment of patients with more persistent forms of AF.

7.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38248888

RESUMO

Vectorcardiographic QRS area is a promising tool for patient selection and implantation guidance in cardiac resynchronization therapy (CRT). Research has mainly focused on the role of QRS area in patient selection for CRT. Recently, QRS area has been proposed as a tool to guide left ventricular lead placement in CRT. Theoretically, vector-based electrical information of ventricular fusion pacing, calculated from the basic 12-lead ECG, can give real-time insight into the extent of resynchronization at any LV lead position, as well as any selected electrode on the LV lead. The objective of this review is to provide an overview of the background of vectorcardiographic QRS area and its potential in optimizing LV lead location in order to optimize the benefits of CRT.

9.
Clin Cardiol ; 47(1): e24161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37872853

RESUMO

BACKGROUND: In the Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See, patients with recent-onset atrial fibrillation (AF) were randomized to either early or delayed cardioversion. AIM: This prespecified sub-analysis aimed to evaluate heart rate during AF recurrences after an emergency department (ED) visit identified by an electrocardiogram (ECG)-based handheld device. METHODS: After the ED visit, included patients (n = 437) were asked to use an ECG-based handheld device to monitor for recurrences during the 4-week follow-up period. 335 patients used the handheld device and were included in this analysis. Recordings from the device were collected and assessed for heart rhythm and rate. Optimal rate control was defined as a target resting heart rate of <110 beats per minute (bpm). RESULTS: In 99 patients (29.6%, mean age 67 ± 10 years, 39.4% female, median 6 [3-12] AF recordings) a total of 314 AF recurrences (median 2 [1-3] per patient) were identified during follow-up. The average median resting heart rate at recurrence was 100 ± 21 bpm in the delayed vs 112 ± 25 bpm in the early cardioversion group (p = .011). Optimal rate control was seen in 68.4% [21.3%-100%] and 33.3% [0%-77.5%] of recordings (p = .01), respectively. Randomization group [coefficient -12.09 (-20.55 to -3.63, p = .006) for delayed vs. early cardioversion] and heart rate on index ECG [coefficient 0.46 (0.29-0.63, p < .001) per bpm increase] were identified on multivariable analysis as factors associated with lower median heart rate during AF recurrences. CONCLUSION: A delayed cardioversion strategy translated into a favorable heart rate profile during AF recurrences.


Assuntos
Fibrilação Atrial , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Eletrocardiografia , Frequência Cardíaca , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
Int J Cardiol Heart Vasc ; 49: 101305, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38053981

RESUMO

Background: In atrial fibrillation (AF) patients, presence of expiratory airflow limitation may negatively impact treatment outcomes. AF patients are not routinely screened for expiratory airflow limitation, but existing examinations can help identify at-risk individuals. We aimed to assess the diagnostic value of repurposing existing assessments from the pre-ablation work-up to identify and understand the characteristics of affected patients. Methods: We screened 110 consecutive AF patients scheduled for catheter ablation with handheld spirometry. Routine pre-ablation work-up included cardiac computed tomographic angiography (CCTA), transthoracic echocardiography and polygraphy. CCTA was analyzed qualitatively for emphysema and airway abnormalities. Multivariate logistic regression analysis was performed to determine predictors of expiratory airflow limitation. Results: We found that 25 % of patients had expiratory airflow limitation, which was undiagnosed in 86 % of these patients. These patients were more likely to have pulmonary abnormalities on CCTA, including emphysema (odds ratio [OR] 4.2, 95 % confidence interval [CI] 1.12-15.1, p < 0.05) and bronchial wall thickening (OR 2.6, 95 % CI 1.0-6.5, p < 0.05). The absence of pulmonary abnormalities on CCTA accurately distinguished patients with normal lung function from those with airflow limitation (negative predictive value: 85 %). Echocardiography and polygraphy did not contribute significantly to identifying airflow limitation. Conclusions: In conclusion, routine pre-ablation CCTA can detect pulmonary abnormalities in AF patients with airflow limitation, guiding further pulmonary assessment. Future studies should investigate its impact on ablation procedure success.

12.
Int J Cardiol Heart Vasc ; 49: 101276, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37854978

RESUMO

Background: The combination of information obtained from pre-procedural cardiac imaging and electro-anatomical mapping (EAM) can potentially help to locate new ablation targets. In this study we developed and evaluated a fully automated technique to align left atrial (LA) anatomies obtained from CT- and MRI-scans with LA anatomies obtained from EAM. Methods: Twenty-one patients scheduled for a pulmonary vein (PV) isolation with a pre-procedural MRI were enrolled. Additionally, a recent computed tomography (CT) scan was available in 12 patients. LA anatomies were segmented from MRI-scans using ADAS-AF (Galgo Medical, Barcelona) and from the CT-scans using Slicer3D. MRI and CT anatomies were aligned with the EAM anatomy using an iterative closest plane-to-plane algorithm. Initially, the algorithm included the PVs, LA appendage and mitral valve anulus as they are the most distinctive landmarks. Subsequently, the algorithm was applied again, excluding these structures, with only three iterative steps to refine the alignment of the true LA surface. The result of the alignments was quantified by the Euclidian distance between the aligned anatomies after excluding PVs, LA appendage and mitral anulus. Results: Our algorithm successfully aligned 20/21 MRI anatomies and 11/12 CT anatomies with the corresponding EAM anatomies. The average median residual distances were 1.9 ± 0.6 mm and 2.5 ± 0.8 mm for MRI and CT anatomies respectively. The average LA surface with a residual distance less than 5.00 mm was 89 ± 9% and 89 ± 10% for MRI and CT anatomies respectively. Conclusion: An iterative closest plane-to-plane algorithm is a reliable method to automatically align pre-procedural cardiac images with anatomies acquired during ablation procedures.

14.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37306315

RESUMO

AIMS: Focus of pacemaker therapy is shifting from right ventricular (RV) apex pacing (RVAP) and biventricular pacing (BiVP) to conduction system pacing. Direct comparison between the different pacing modalities and their consequences to cardiac pump function is difficult, due to the practical implications and confounding variables. Computational modelling and simulation provide the opportunity to compare electrical, mechanical, and haemodynamic consequences in the same virtual heart. METHODS AND RESULTS: Using the same single cardiac geometry, electrical activation maps following the different pacing strategies were calculated using an Eikonal model on a three-dimensional geometry, which were then used as input for a lumped mechanical and haemodynamic model (CircAdapt). We then compared simulated strain, regional myocardial work, and haemodynamic function for each pacing strategy. Selective His-bundle pacing (HBP) best replicated physiological electrical activation and led to the most homogeneous mechanical behaviour. Selective left bundle branch (LBB) pacing led to good left ventricular (LV) function but significantly increased RV load. RV activation times were reduced in non-selective LBB pacing (nsLBBP), reducing RV load but increasing heterogeneity in LV contraction. LV septal pacing led to a slower LV and more heterogeneous LV activation than nsLBBP, while RV activation was similar. BiVP led to a synchronous LV-RV, but resulted in a heterogeneous contraction. RVAP led to the slowest and most heterogeneous contraction. Haemodynamic differences were small compared to differences in local wall behaviour. CONCLUSION: Using a computational modelling framework, we investigated the mechanical and haemodynamic outcome of the prevailing pacing strategies in hearts with normal electrical and mechanical function. For this class of patients, nsLBBP was the best compromise between LV and RV function if HBP is not possible.


Assuntos
Ventrículos do Coração , Septo Interventricular , Humanos , Sistema de Condução Cardíaco , Miocárdio , Simulação por Computador
15.
J Clin Med ; 12(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37373721

RESUMO

BACKGROUND: Implantation of a permanent pacemaker and atrioventricular (AV) node ablation (pace-and-ablate) is an established approach for rate and symptom control in elderly patients with symptomatic atrial fibrillation (AF). Left bundle branch area pacing (LBBAP) is a physiological pacing strategy that might overcome right ventricular pacing-induced dyssynchrony. In this study, the feasibility and safety of performing LBBAP and AV node ablation in a single procedure in the elderly was investigated. METHODS: Consecutive patients with symptomatic AF referred for pace-and-ablate underwent the treatment in a single procedure. Data on procedure-related complications and lead stability were collected at regular follow-up at one day, ten days and six weeks after the procedure and continued every six months thereafter. RESULTS: 25 patients (mean age 79.2 ± 4.2 years) were included and underwent successful LBBAP. In 22 (88%) patients, AV node ablation and LBBAP were performed in the same procedure. AV node ablation was postponed in two patients due to lead-stability concerns and in one patient on their own request. No complications related to the single-procedure approach were observed with no lead-stability issues at follow-up. CONCLUSIONS: LBBAP combined with AV node ablation in a single procedure is feasible and safe in elderly patients with symptomatic AF.

17.
Eur Heart J Case Rep ; 7(4): ytad162, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37123652

RESUMO

Background: The 'double fire' (DF) atrioventricular (AV) nodal response is a rare mechanism of two ventricular electrical activations following a single atrial beat due to dual AV node physiology. DF AV nodal response is often misdiagnosed and may lead to unnecessary invasive procedures. Case summary: We describe a series of three cases with distinct clinical manifestations of DF AV nodal response: Patient 1 remained symptomatic after slow pathway modification for common AV nodal re-entry tachycardia. Patient 2 was misdiagnosed as having junctional bigeminy and developed heart failure with reduced left ventricle ejection fraction. Patient 3 was misdiagnosed as having atrial fibrillation (AF) and underwent two pulmonary vein isolation (PVI) procedures, without clinical improvement. All patients underwent an electrophysiological study (EPS) during which DF AV nodal response was confirmed and treated with radiofrequency ablation of the slow pathway. All patients were afterwards relieved from their symptoms. Discussion and conclusion: DF AV nodal response is a rare electrophysiological phenomenon which can be clinically misinterpreted as other common arrhythmias, such as premature junctional bigeminy or AF and can contribute to tachycardia induced cardiomyopathy. Typical electrocardiogram- and EPS-derived findings can be indicative for DF AV nodal response. DF AV nodal response can be easily and effectively treated by slow pathway ablation.

18.
J Cardiovasc Electrophysiol ; 34(4): 1006-1014, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36906812

RESUMO

INTRODUCTION: We aimed to investigate the impact of the 2021 European Society of Cardiology (ESC) guideline changes in left bundle branch block (LBBB) definition on cardiac resynchronization therapy (CRT) patient selection and outcomes. METHODS: The MUG (Maastricht, Utrecht, Groningen) registry, consisting of consecutive patients implanted with a CRT device between 2001 and 2015 was studied. For this study, patients with baseline sinus rhythm and QRS duration ≥ 130ms were eligible. Patients were classified according to ESC 2013 and 2021 guideline LBBB definitions and QRS duration. Endpoints were heart transplantation, LVAD implantation or mortality (HTx/LVAD/mortality) and echocardiographic response (LVESV reduction ≥15%). RESULTS: The analyses included 1.202, typical CRT patients. The ESC 2021 definition resulted in considerably less LBBB diagnoses compared to the 2013 definition (31.6% vs. 80.9%, respectively). Applying the 2013 definition resulted in significant separation of the Kaplan-Meier curves of HTx/LVAD/mortality (p < .0001). A significantly higher echocardiographic response rate was found in the LBBB compared to the non-LBBB group using the 2013 definition. These differences in HTx/LVAD/mortality and echocardiographic response were not found when applying the 2021 definition. CONCLUSION: The ESC 2021 LBBB definition leads to a considerably lower percentage of patients with baseline LBBB then the ESC 2013 definition. This does not lead to better differentiation of CRT responders, nor does this lead to a stronger association with clinical outcomes after CRT. In fact, stratification according to the 2021 definition is not associated with a difference in clinical or echocardiographic outcome, implying that the guideline changes may negatively influence CRT implantation practice with a weakened recommendation in patients that will benefit from CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Humanos , Bloqueio de Ramo/diagnóstico , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Eletrocardiografia/métodos , Arritmias Cardíacas/terapia , Ecocardiografia
20.
Clin Res Cardiol ; 112(6): 834-845, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36773038

RESUMO

BACKGROUND: Sleep-disordered breathing (SDB) is prevalent in up to 50% of patients referred for atrial fibrillation (AF) catheter ablation (CA). Currently, it remains unclear how to improve pre-selection for SDB screening in patients with AF. AIM: We aimed to (1) assess the accuracy of the STOP-Bang screening questionnaire for detection of SDB within an AF population referred for CA; (2) derive a refined, AF-specific SDB score to improve pre-selection. METHODS: Consecutive AF patients referred for CA without a history of SDB and/or SDB screening were included. Patients were digitally referred to the previously implemented Virtual-SAFARI SDB screening and management pathway including a home sleep test. An apnoea-hypopnoea index (AHI) of  ≥ 15 was interpreted as moderate-to-severe SDB. Logistic regression analysis was used to assess characteristics associated with moderate-to-severe SDB to refine pre-selection for SDB screening. RESULTS: Of 206 included patients, 51% were diagnosed with moderate-to-severe SDB. The STOP-Bang questionnaire performed poorly in detecting SDB, with an area under the receiver operating characteristic curve (AUROC) of 0.647 (95% Confidence-Interval (CI) 0.573-0.721). AF-specific refinement resulted in the BOSS-GAP score. Therein, BMI with cut-off point ≥ 27 kg/m2 and previous stroke or transient ischaemic attack (TIA) were added, while tiredness and neck circumference were removed. The BOSS-GAP score performed better with an AUROC of 0.738 (95% CI 0.672-0.805) in the overall population. CONCLUSION: AF-specific refinement of the STOP-Bang questionnaire moderately improved detection of SDB in AF patients referred for CA. Whether questionnaires bring benefits for pre-selection of SDB compared to structural screening in patients with AF requires further studies. TRIAL REGISTRATION NUMBER: ISOLATION was registered NCT04342312, 13-04-2020.


Assuntos
Fibrilação Atrial , Síndromes da Apneia do Sono , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Inquéritos e Questionários , Polissonografia/métodos , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...