Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 103(4): 044501, 2009 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-19659360

RESUMO

We present the first simultaneous space-time measurements for gravity wave turbulence in a large laboratory flume. We found that the slopes of k and omega wave spectra depend on wave intensity. This cannot be explained by any existing theory considering wave turbulence as the result of either breaking events or weakly nonlinear wave interactions. Instead, we show that random waves and breaking or coherent structures appear to coexist: The former show themselves in a quasi-Gaussian core of the probability density function and in the low-order structure functions, and the latter in the probability density function tails and the high-order structure functions.

2.
J Acoust Soc Am ; 124(2): EL40-4, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18681500

RESUMO

Acoustic impulses due to an electrical spark source (main acoustic energy near 15 kHz) have been measured after propagating near to the water surface in a shallow container resting on a vibrating platform. Control of the platform vibration enabled control of water wave amplitudes. Analysis of the results reveals systematic variations in the received acoustic waveforms as the mean trough-to-crest water wave amplitude is increased up to 7 mm. The amplitudes of the peaks corresponding to specular reflections are reduced and the variability in the tails of the waveforms is increased.


Assuntos
Acústica , Som , Água/química , Impedância Elétrica , Modelos Teóricos , Reprodutibilidade dos Testes , Espectrografia do Som , Fatores de Tempo , Vibração
3.
Phys Rev Lett ; 99(1): 014501, 2007 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-17678155

RESUMO

We present an experimental study of the statistics of surface gravity wave turbulence in a flume of a horizontal size 12 x 6 m. For a wide range of amplitudes the wave energy spectrum was found to scale as Eomega approximately omega(-nu) in a frequency range of up to one decade. However, nu appears to be nonuniversal: it depends on the wave intensity and ranges from about 6 to 4. We discuss our results in the context of existing theories and argue that at low wave amplitudes the wave statistics is affected by the flume finite size, and at high amplitudes the wave breaking effect dominates.

4.
J Ultrasound Med ; 21(12): 1405-12, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12494983

RESUMO

OBJECTIVE: To evaluate a new angle-independent ultrasonic device for assessment of blood flow volume in the internal carotid artery. METHODS: In vitro, a pulsatile pump was set to provide an outflow of physiological fluid at 500 mL/min through an 8-mm-diameter tube. Flow volume rates were measured 10 times by 10 different operators and compared with time-collected flow volume rates. In vivo, internal and common carotid artery blood flow volumes were measured in 28 volunteers by 2 operators using a FlowGuard device (Biosonix Ltd). Internal and common carotid artery diameters and blood flow volumes were also assessed by Duplex sonography and compared with FlowGuard measurements. In 10 volunteers, internal carotid artery blood flow volume changes in response to monitored breath manipulations were recorded. RESULTS: In vitro, intraoperator variability was 4.04% (range, 2%-5.7%). The mean error rate +/- SD was 3.54% +/- 0.8% (range, 2.7%-5.2%). In vivo, the mean common carotid artery blood flow volume was 456 +/- 39 mL/min (range, 417-583 mL/min) with a mean diameter of 6.7 +/- 0.7 mm (range, 5.8-8.7 mm). The mean internal carotid artery blood flow volume was 277 +/- 25 mL/min (range, 239-338 mL/min) with a mean diameter of 5 +/- 0.5 mm (range, 4.1-6.1 mm). No significant difference was found between operators. Internal carotid artery diameter and blood flow volume measured by the FlowGuard were closely correlated with the results of Duplex sonography. Repeated shifts of end-tidal CO2 induced reproducible changes in internal carotid artery flow volume: 187.5 +/- 18.1 mL/min at 26.8 +/- 1.9 mm Hg and 382.1 +/- 18.2 mL/min at 47 +/- 2.2 mm Hg. CONCLUSIONS: The FlowGuard showed that volume flow studies in the internal carotid artery could be easily performed, with results compatible with those of previous clinical reports. Duplex comparative results and breath-induced changes in internal carotid artery flow volume justify further evaluation of the system.


Assuntos
Artéria Carótida Externa/diagnóstico por imagem , Ultrassonografia Doppler Dupla/instrumentação , Adulto , Análise de Variância , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Artéria Carótida Externa/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...