1.
Prehosp Emerg Care ; 13(3): 371-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19499476

RESUMO

OBJECTIVE: To compare four field-appropriate torso-warming modalities that do not require alternating-current (AC) electrical power, using a human model of nonshivering hypothermia. METHODS: Five subjects, serving as their own controls, were cooled four times in 8 degrees C water for 10-30 minutes. Shivering was inhibited by buspirone (30 mg) taken orally prior to cooling and intravenous (IV) meperidine (1.25 mg/kg) at the end of immersion. Subjects were hoisted out of the water, dried, and insulated and then underwent 120 minutes of one of the following: spontaneous warming only; a charcoal heater on the chest; two flexible hot-water bags (total 4 liters of water at 55 degrees C, replenished every 20 minutes) applied to the chest and upper back; or two chemical heating pads applied to the chest and upper back. Supplemental meperidine (maximum cumulative dose of 3.5 mg/kg) was administered as required to inhibit shivering. RESULTS: The postcooling afterdrop (i.e., the continued decrease in body core temperature during the early period of warming), compared with spontaneous warming (2.2 degrees C), was less for the chemical heating pads (1.5 degrees C) and the hot-water bags (1.6 degrees C, p < 0.05) and was 1.8 degrees C for the charcoal heater. Subsequent core rewarming rates for the hot-water bags (0.7 degree C/h) and the charcoal heater (0.6 degree C/h) tended to be higher than that for the chemical heating pads (0.2 degree C/h) and were significantly higher than that for spontaneous warming rate (0.1 degrees C/h, p < 0.05). CONCLUSION: In subjects with shivering suppressed, greater sources of external heat were effective in attenuating core temperature afterdrop, whereas sustained sources of external heat effectively established core rewarming. Depending on the scenario and available resources, we recommend the use of charcoal heaters, chemical heating pads, or hot-water bags as effective means for treating cold patients in the field or during transport to definitive care.


Assuntos
Temperatura Corporal/fisiologia , Hipotermia/terapia , Reaquecimento/instrumentação , Adulto , Serviços Médicos de Emergência , Desenho de Equipamento , Humanos , Masculino , Manitoba , Monitorização Fisiológica
2.
Prehosp Disaster Med ; 24(5): 408-15, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20066643

RESUMO

INTRODUCTION: In a cold, wet, or windy environment, cold exposure can be considerable for an injured or ill person. The subsequent autonomous stress response initially will increase circulatory and respiratory demands, and as body core temperature declines, the patient's condition might deteriorate. Therefore, the application of adequate insulation to reduce cold exposure and prevent body core cooling is an important part of prehospital primary care, but recommendations for what should be used in the field mostly depend on tradition and experience, not on scientific evidence. OBJECTIVE: The objective of this study was to evaluate the thermal insulation properties in different wind conditions of 12 different blankets and rescue bags commonly used by prehospital rescue and ambulance services. METHODS: The thermal manikin and the selected insulation ensembles were setup inside a climatic chamber in accordance to the modified European Standard for assessing requirements of sleeping bags. Fans were adjusted to provide low (< 0.5 m/s), moderate (2-3 m/s) and high (8-9 m/s) wind conditions. During steady state thermal transfer, the total resultant insulation value, Itr (m2 C/Wclo; where C = degrees Celcius, and W = watts), was calculated from ambient air temperature (C), manikin surface temperature (C), and heat flux (W/m2). RESULTS: In the low wind condition, thermal insulation of the evaluated ensembles correlated to thickness of the ensembles, ranging from 2.0 to 6.0 clo (1 clo = 0.155 m2 C/W), except for the reflective metallic foil blankets that had higher values than expected. In moderate and high wind conditions, thermal insulation was best preserved for ensembles that were windproof and resistant to the compressive effect of the wind, with insulation reductions down to about 60-80% of the original insulation capacity, whereas wind permeable and/or lighter materials were reduced down to about 30-50% of original insulation capacity. CONCLUSIONS: The evaluated insulation ensembles might all be used for prehospital protection against cold, either as single blankets or in multiple layer combinations, depending on ambient temperatures. However, with extended outdoor, on-scene durations, such as during prolonged extrications or in multiple casualty situations, the results of this study emphasize the importance of using a windproof and compression resistant outer ensemble to maintain adequate insulation capacity.


Assuntos
Regulação da Temperatura Corporal , Temperatura Baixa/efeitos adversos , Serviços Médicos de Emergência , Exposição Ambiental/prevenção & controle , Roupa de Proteção , Vento , Serviços Médicos de Emergência/métodos , Exposição Ambiental/efeitos adversos , Humanos , Hipotermia/prevenção & controle , Manequins