Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38206100

RESUMO

The imaging heavy ion beam probe (i-HIBP) diagnostic has been successfully commissioned at ASDEX Upgrade. The i-HIBP injects a primary neutral beam into the plasma, where it is ionized, leading to a fan of secondary (charged) beams. These are deflected by the magnetic field of the tokamak and collected by a scintillator detector, generating a strike-line light pattern that encodes information on the density, electrostatic potential, and magnetic field of the plasma edge. The first measurements have been made, demonstrating the proof-of-principle of this diagnostic technique. A primary beam of 85/87Rb has been used with energies ranging between 60 and 72 keV and extracted currents up to 1.5 mA. The first signals have been obtained in experiments covering a wide range of parameter spaces, with plasma currents (Ip) between 0.2 and 0.8 MA and on-axis toroidal magnetic field (Bt) between 1.9 and 2.7 T. Low densities appear to be critical for the performance of the diagnostic, as signals are typically observed only when the line integrated density is below 2.0-3.0 × 1019 m-2 in the central interferometer chord, depending on the plasma shape. The strike line moves as expected when Ip is ramped, indicating that current measurements are possible. Additionally, clear dynamics in the intensity of the strike line are often observed, which might be linked to changes in the edge profile structure. However, the signal-to-background ratio of the signals is hampered by stray light, and the image guide degradation is due to neutron irradiation. Finally, simulations have been carried out to investigate the sensitivity of the expected signals to plasma density and temperature. The results are in qualitative agreement with the experimental observations, suggesting that the diagnostic is almost insensitive to fluctuations in the temperature profile, while the signal level is highly determined by the density profile due to the beam attenuation.

2.
Phys Rev Lett ; 130(14): 145102, 2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37084430

RESUMO

We present a novel concept to tackle the power exhaust challenge of a magnetically confined fusion plasma. It relies on the prior establishment of an X-point radiator that dissipates a large fraction of the exhaust power before it reaches the divertor targets. Despite the spatial proximity of the magnetic X point to the confinement region, this singularity is far away from the hot fusion plasma in magnetic coordinates and therefore allows the coexistence of a cold and dense plasma with a high potential to radiate. In the compact radiative divertor (CRD) the target plates are placed close to this magnetic X point. We here report on high performance experiments in the ASDEX Upgrade tokamak that indicate the feasibility of this concept. Despite the shallow (projected) field line incidence angles of the order of θ_{⊥}=0.2°, no hot spots were observed on the target surface monitored by an IR camera, even at a maximum heating power of P_{heat}=15 MW. And even with the X point located exactly on the target surface and without density or impurity feedback control, the discharge remains stable, the confinement good (H_{98,y2}=1), hot spots absent, and the divertor in a detached state. In addition to its technical simplicity, the CRD scales beneficially to reactor-scale plasmas that would benefit from an increased volume of the confined plasma, more space for breeding blankets, smaller poloidal field coil currents, and-potentially-an increased vertical stability.

3.
Rev Sci Instrum ; 92(5): 053538, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243326

RESUMO

A poloidal array of scintillator-based Fast-Ion Loss Detectors (FILDs) has been installed in the ASDEX Upgrade (AUG) tokamak. While all AUG FILD systems are mounted on reciprocating arms driven externally by servomotors, the reciprocating system of the FILD probe located just below the midplane is based on a magnetic coil that is energized in real-time by the AUG discharge control system. This novel reciprocating system allows, for the first time, real-time control of the FILD position including infrared measurements of its probe head temperature to avoid overheating. This considerably expands the diagnostic operational window, enabling unprecedented radial measurements of fast-ion losses. Fast collimator-slit sweeping (up to 0.2 mm/ms) is used to obtain radially resolved velocity-space measurements along 8 cm within the scrape-off layer. This provides a direct evaluation of the neutral beam deposition profiles via first-orbit losses. Moreover, the light-ion beam probe (LIBP) technique is used to infer radial profiles of fast-ion orbit deflection. This radial-LIBP technique is applied to trapped orbits (exploring both the plasma core and the FILD stroke near the wall), enabling radial localization of internal plasma fluctuations (neoclassical tearing modes). This is quantitatively compared against electron cyclotron emission measurements, showing excellent agreement. For the first time, radial profiles of fast-ion losses in MHD quiescent plasmas as well as in the presence of magnetic islands and edge localized modes are presented.

4.
Rev Sci Instrum ; 90(4): 043504, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31043003

RESUMO

Ray-tracing techniques are applied to filtered divertor imaging, a diagnostic that has long suffered from artifacts due to the polluting effect of reflected light in metal walled fusion machines. Physically realistic surface reflections were modeled using a Cook-Torrance micro-facet bi-directional reflection distribution function applied to a high resolution mesh of the vessel geometry. In the absence of gonioreflectometer measurements, a technique was developed to fit the free parameters of the Cook-Torrance model against images of the JET in-vessel light sources. By coupling this model with high fidelity plasma fluid simulations, photo-realistic renderings of a number of tokamak plasma emission scenarios were generated. Finally, a sensitivity matrix describing the optical coupling of a JET divertor camera and the emission profile of the plasma was obtained, including full reflection effects. These matrices are used to perform inversions on measured data and shown to reduce the level of artifacts in inverted emission profiles.

5.
Rev Sci Instrum ; 88(3): 033509, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372367

RESUMO

In magnetically confined fusion plasmas controlled gas injection is crucial for plasma fuelling as well as for various diagnostic applications such as active spectroscopy. We present a new, versatile system for the injection of collimated thermal gas beams into a vacuum chamber. This system consists of a gas pressure chamber, sealed by a custom made piezo valve towards a small capillary for gas injection. The setup can directly be placed inside of the vacuum chamber of fusion devices as it is small and immune against high magnetic fields. This enables gas injection close to the plasma periphery with high duty cycles and fast switch on/off times ≲ 0.5 ms. In this work, we present the design details of this new injection system and a systematic characterization of the beam properties as well as the gas flowrates which can be accomplished. The thin and relatively short capillary yields a small divergence of the injected beam with a half opening angle of 20°. The gas box is designed for pre-fill pressures of 10 mbar up to 100 bars and makes a flowrate accessible from 1018 part/s up to 1023 part/s. It hence is a versatile system for both diagnostic as well as fuelling applications. The implementation of this system in ASDEX Upgrade will be described and its application for line ratio spectroscopy on helium will be demonstrated on a selected example.

6.
Rev Sci Instrum ; 87(2): 023508, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931850

RESUMO

Experiments have been performed at ASDEX Upgrade, aiming to investigate the impact of lithium in an all-metal-wall tokamak and attempting to enhance the pedestal operational space. For this purpose, a lithium pellet injector has been developed, capable of injecting pellets carrying a particle content ranging from 1.82 × 10(19) atoms (0.21 mg) to 1.64 × 10(20) atoms (1.89 mg). The maximum repetition rate is about 2 Hz. Free flight launch from the torus outboard side without a guiding tube was realized. In such a configuration, angular dispersion and speed scatter are low, and a transfer efficiency exceeding 90% was achieved in the test bed. Pellets are accelerated in a gas gun; hence special care was taken to avoid deleterious effects by the propellant gas pulse. Therefore, the main plasma gas species was applied as propellant gas, leading to speeds ranging from 420 m/s to 700 m/s. In order to minimize the residual amount of gas to be introduced into the plasma vessel, a large expansion volume equipped with a cryopump was added into the flight path. In view of the experiments, an optimal propellant gas pressure of 50 bars was chosen for operation, since at this pressure maximum efficiency and low propellant gas flux coincide. This led to pellet speeds of 585 m/s ± 32 m/s. Lithium injection has been achieved at ASDEX Upgrade, showing deep pellet penetration into the plasma, though pedestal broadening has not been observed yet.

7.
J Clin Microbiol ; 54(3): 785-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26719436

RESUMO

We evaluated a multiplexed PCR panel for the detection of 16 bacterial, viral, and fungal pathogens in cerebrospinal fluid. Panel results were compared to routine testing, and discrepancies were resolved by additional nucleic acid amplification tests or sequencing. Overall, the positive and negative agreements across methods were 92.9% and 91.9%, respectively.


Assuntos
Automação , Infecções do Sistema Nervoso Central/diagnóstico , Infecções do Sistema Nervoso Central/etiologia , Reação em Cadeia da Polimerase Multiplex , Humanos , Reação em Cadeia da Polimerase Multiplex/métodos , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Rev Sci Instrum ; 84(7): 073501, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23902057

RESUMO

This paper describes the design and operation of a new tungsten (W) injection system for impurity transport experiments in the Tore Supra tokamak. The system is mounted on a reciprocating manipulator and injects a controlled amount of gaseous tungsten hexacarbonyl, W(CO)6 at arbitrary depth in the scrape-off layer, using an inertially activated valve. Injected W(CO)6 is dissociated in the plasma, forming a radially localized plume of W atoms. The injector does not require an external gas feed and can perform a large number of injections from an on-board reservoir of W(CO)6. Some examples of W injections in Tore Supra are included, demonstrating successful operation and discussing some technical issues of the injector prototype.

9.
Phys Rev Lett ; 106(22): 225004, 2011 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-21702608

RESUMO

First experiments with nonaxisymmetric magnetic perturbations, toroidal mode number n=2, produced by newly installed in-vessel saddle coils in the ASDEX Upgrade tokamak show significant reduction of plasma energy loss and peak divertor power load associated with type-I edge localized modes (ELMs) in high-confinement mode plasmas. ELM mitigation is observed above an edge density threshold and is obtained both with magnetic perturbations that are resonant and not resonant with the edge safety factor profile. Compared with unperturbed type-I ELMy reference plasmas, plasmas with mitigated ELMs show similar confinement, similar plasma density, and lower tungsten impurity concentration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...