Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 43(2): 230-234, 2021 Apr 28.
Artigo em Chinês | MEDLINE | ID: mdl-33966703

RESUMO

Objective To investigate the role of dual-layer detector energy spectral CT in resting myocardial perfusion imaging for patients with normal coronary artery. Methods One hundred and fifty-six patients with suspected coronary heart disease underwent dual-layer detector energy spectral CT coronary angiography,and resting myocardial perfusion imaging was performed for 28 patients with normal coronary artery.According to American Heart Association's 17-segmentmodel,the iodine density and effective atomic number(Zeff value)of each myocardial segment(except for apical segment)were measured and normalized to those of the aorta.All the data were quantitatively evaluated using ANOVA or Friedman test. Results Iodine density and Zeff value of myocardial segments in middle plane were significantly different(all P<0.001).The iodine density and Zeff value showed no significant difference between segments in basal and apical plane(all P > 0.05). Conclusions Iodine density and Zeff value of myocardial segments can be quantitatively evaluated using dual-layer detector energy spectral CT.Resting myocardial perfusion of segments in middle plane are significantly different in patients with normal coronary artery.


Assuntos
Imagem de Perfusão do Miocárdio , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
2.
Anat Rec (Hoboken) ; 302(6): 1024-1038, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30779320

RESUMO

This study was performed to investigate whether miniature pigs are a suitable animal model for studies of the Eustachian tube (ET). Sixteen Chinese experimental miniature pigs were used in this investigation. Ten animals were used for anatomical and morphometric analyses to obtain qualitative and quantitative information regarding the ET. Three animals were used for histological analysis to determine the fine structure of ET cross-sections. Three animals were used to investigate the feasibility of balloon dilation of the Eustachian tube (BDET). The anatomical study indicated that the pharyngeal orifice and tympanic orifice of the miniature pig ET are located at the posterior end of the nasal lateral wall and anterior wall of the middle ear cavity, respectively. The cartilaginous tube was seen to pass through the whole length of the ET, the length of the cartilaginous part of the ET and the diameter of the isthmus were similar between humans and miniature pigs. The inclination of the ET in miniature pigs was larger than that in humans. The gross histology seemed to be slightly different between miniature pig and human, but the fine structures were essentially the same in both species. BDET experiments verified that the miniature pig model is suitable as a model for clinical operations. The miniature pig ET corresponds very well to that of humans. In addition, the miniature pig ET is suitable as a model for clinical operations. Therefore, the miniature pig is a valid animal model for ET study. Anat Rec, 302:1024-1038, 2019. © 2019 Wiley Periodicals, Inc.


Assuntos
Modelos Animais de Doenças , Tuba Auditiva/anatomia & histologia , Porco Miniatura/anatomia & histologia , Suínos/anatomia & histologia , Animais , Colesteatoma da Orelha Média/etiologia , Colesteatoma da Orelha Média/cirurgia , Tuba Auditiva/cirurgia , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Otite Média/etiologia , Otite Média/cirurgia , Especificidade da Espécie
3.
Chin Med Sci J ; 33(2): 69-76, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29976275

RESUMO

To identify the risk factors that are associated with the midterm coronary artery bypass grafting (CABG) functionality by assessing patency of left internal mammary artery (LIMA) graft and saphenous vein (SV) graft with 64-slice multi-detector computed tomography (64-MDCT).Methods Patients who underwent CABG operation and postoperative 64-MDCT follow-up examinations from August 2012 to December 2015 were included. The graft patent status was classified into patent and poor patent according to MDCT findings predominantly on 3D reconstructed images by two radiologists. The clinical data and imaging findings of the patients were collected and compared between the patent group and poor patent group. Univariate analysis and the multivariate logistic regression analysis were performed to identify the risk factors that affect graft patency.Results Among 341 patients in the study, there were 330 LIMA grafts [326 anastomosed to the left anterior descending artery (LAD), 4 to right coronary artery (RCA)] and 564 SV grafts (SVG) [100 anastomosed to the diagonal branch (D), 226 to the obtuse marginal branch (OM), and 238 to the RCA territory]. The approximal vessel stenosis exceeding 90% occurred in 268 of 292 patent LIMA grafts, and in 1 of 34 poor patent grafts (χ 2=167, P<0.001). The patency rate was higher when SVG was anastomosed to OM (85.4%) or RCA territory (81.9%) than to D (69.0%) (χ 2=15.471, P=0.004). The proximal target vessel stenosis < 90% (OR= 0.015, 95% CI: 0.01-0.14, P=0.000) was independently associated with the closure risk of LIMA grafts, the dyslipidemia (OR= 1.52, 95% CI: 1.0-2.5, P=0.048), history of diabetes (OR = 1.28, 95% CI : 0.90-2.26, P=0.045) and typical angina symptoms (OR=1.81, 95% CI :1.33-4.15, P=0.003) were independently associated with the closure risk of SVG. Conclusions The proximal LAD stenosis less than 90% was adversely associated with graft patency in LIMA recipients; dyslipidemia, diabetes and angina symptoms were associated with the midterm failure in SVG recipients. The choice of the target anastomosis sites may affect the patency of SVG.


Assuntos
Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
4.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 40(6): 744-749, 2018 Dec 20.
Artigo em Chinês | MEDLINE | ID: mdl-30606383

RESUMO

Objective To assess the value of CT angiography using low-voltage and low-concentration contrast media (CM) combined with knowledge-based iterative model reconstruction (IMR) in patients with coronary artery bypass grafts (CABG).Methods Totally 71 patients after CABG undergoing CT angiography in our center from June to November 2016 were prospectively enrolled and randomly assigned into groups A and B. The scan protocol for group A was 80 kVp with 300 mgI/ml contrast at an injection rate of 4 ml/s;images were reconstructed by IMR algorithm. The scan protocol for group B was 100 kVp with 370 mgI/ml contrast at an injection rate of 5 ml/s;images were reconstructed by hybrid iterative reconstruction technique. Aorta,left ventricular,and grafts were chosen as regions of interest. The image quality,radiation dose,and contrast load were compared between two groups.Results The signal to noise ratio (SNR) and contrast to noise ratio (CNR) of the ascending aorta,descending aorta,left ventricular,and venous bridge in group A [SNR:19±5,20±5.7,19.1±4.9,and 37±34;CNR:17±4.7,18±5,16±5.4,and 34±32] were significantly higher than those in group B [SNR:16±6 (P=0.012),15.6±5.5 (P=0.002),15±6 (P=0.002),24±8.3 (P=0.035);CNR:14±5.5 (P=0.010),13.8±5(P=0.002),13±5.7 (P=0.014),21±7.8 (P=0.031)],except for left internal mammary artery graft (LIMA),which was not inferior to that in group B. An effective radiation dose reduction of 49% was achieved in group A [(2.3±0.4) mSv,compared with group B (4.5±0.5) mSv (P=0.000)]. The iodine load of group A was (20±1.4) g compared with (29±1.6) g in group B,resulting in a reduction of 31% (P=0.000).Conclusions The low tube voltage (80 kVp) and low contrast protocol combined with IMR in patients with CABG can reduce radiation dose and improve image quality of aorta,left ventricular and venous graft. The image quality of LIMA graft in low dose group is not inferior to that in regular dose group.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária , Interpretação de Imagem Radiográfica Assistida por Computador , Meios de Contraste , Humanos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...