J Biomed Opt ; 24(3): 1-11, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30834722

RESUMO

The optical attenuation coefficient (OAC) reflects the optical properties of various tissues or tissues of the same type under different physiological conditions. Quantitative measurement of OAC from optical coherence tomography (OCT) signals can provide additional information and can increase the potential for OCT applications. We present an optimized depth-resolved estimation (ODRE) method that derives a precise mapping between the measured OCT signal and the OAC. In contrast to previous depth-resolved estimation (DRE) methods, the optimized method can estimate the OAC in any depth range and ignore whether the light is completely attenuated. Numerical simulations and phantom experiments are used to verify its validity, and this method is applied to detect cerebral damage. In combination with OCT angiography, real-time observation of the change of blood perfusion and the degree of cerebral damage in mice with focal cerebral ischemia provides important information to help us understand the temporal relationship between brain damage and ischemia.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Algoritmos , Animais , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Angiografia Cerebral , Simulação por Computador , Camundongos , Imagens de Fantasmas
2.
Biomed Opt Express ; 9(12): 6103-6115, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31065416

RESUMO

We propose a high speed all-optic dual-modal system that combines spectral domain optical coherence tomography (SDOCT) and photoacoustic imaging (PAI) to evaluate microvasculature flow states. A homodyne interferometer was used to remotely detect the surface vibration caused by photoacoustic (PA) waves. The PA excitation, PA probing and SDOCT probing beams share the same X-Y galvanometer scanner to perform fast two-dimensional scanning. In addition, we introduced multi-excitation, dual-channel acquisition and sensitivity compensation to improve the imaging speed of the PAI sub-system. The total time for imaging a sample with 256 × 256 pixels is less than 1 minute. The performance of the proposed system was verified by in vivo imaging of the vascular system in a mouse pinna with normal and then blocked blood circulations. The experimental results indicate that the proposed system is capable of revealing different blood flow states (static and moving) and is useful for the study of diseases related to functional blood supply.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...