Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Am ; 89(12): 2676-83, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18056500

RESUMO

BACKGROUND: Wear debris has been implicated in the pathogenesis of osteolysis. Alumina-on-alumina ceramic bearings have a low wear rate, which may reduce the prevalence of osteolysis. The purpose of this study was to determine the rates of wear and osteolysis associated with modern cementless hip arthroplasty with alumina-on-alumina bearings at five years. METHODS: We analyzed a series of 301 third-generation alumina-on-alumina cementless primary total hip replacements in 283 patients. The average age of the patients at the time of the arthroplasty was fifty-eight years. All procedures were performed with use of the same surgical technique and the same implant at a single center. At a minimum of five years postoperatively, ten patients had died and twenty-two patients were lost to follow-up. We assessed patients clinically and radiographically, and all retrieved bearings were analyzed for wear. RESULTS: At the time of the latest follow-up, the mean Harris hip score was 95 points. All surviving implants had radiographic evidence of stable bone ingrowth. There were nine revisions of one or both components. Four stems were revised following periprosthetic fracture, one stem was revised because of aseptic loosening at two months, and one stem was revised to facilitate a femoral shortening osteotomy. Two cups were revised because of psoas tendinitis, and both components of one arthroplasty were revised because of impingement and osteolysis. The rate of survival of both components, with revision because of aseptic loosening or osteolysis as the end point, was 99% at seven years. The retrieved femoral heads showed an early median wear rate of 0.2 mm(3) per year. CONCLUSIONS: Cementless primary total hip prostheses with a third-generation alumina-on-alumina bearing showed very low wear and were associated with minimal osteolysis at the time of follow-up, at a minimum of five years.


Assuntos
Artroplastia de Quadril/instrumentação , Osteólise/prevenção & controle , Desenho de Prótese , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Radiografia , Reoperação
2.
J Bone Joint Surg Br ; 89(9): 1158-64, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17905951

RESUMO

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm(3)/yr for the femoral heads, and 0.04 mm(3)/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15 degrees (seven femoral heads) had a median femoral head wear rate of 1.2 mm(3)/yr, compared with 0 mm(3)/yr for those with an anteversion of > or =15 degrees (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Acetábulo/cirurgia , Cerâmica , Análise de Falha de Equipamento/métodos , Humanos , Orientação , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...