1.
Radiat Prot Dosimetry ; 180(1-4): 422-426, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29177516

RESUMO

The response of albedo dosemeters depends on the energy and angle of the incident neutron radiation. For their use as personal dosemeters, a field-calibration factor has to be applied. The presently used single sphere method for field calibration can be extended and optimised by putting five albedo dosemeters on the surface of a polyethylene sphere and two TL cards in the centre. To investigate the potential of this extension, reference measurements and Monte Carlo calculations were performed and the fluence response of the detectors at different positions on and within the sphere was determined. Calculated response functions demonstrate that information on the energy and directional distribution of neutron fluence can be extracted with this simple set-up for unknown neutron fields.


Assuntos
Nêutrons , Exposição Ocupacional/análise , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Local de Trabalho , Simulação por Computador , Desenho de Equipamento , Humanos , Método de Monte Carlo , Doses de Radiação , Monitoramento de Radiação/instrumentação
2.
Radiat Prot Dosimetry ; 180(1-4): 98-101, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136231

RESUMO

The neutron field of the PTB Thermal Neutron Calibration Facility was characterised with the help of the Bonner sphere spectrometer of PTB, NEutron MUltisphere Spectrometer (NEMUS). For the analysis of the Bonner sphere data an analytical model of the neutron energy distribution was used. The unfolding of neutron spectra was performed via the method of Bayesian parameter estimation. Comparison of the results of thermal neutron fluence and thermal ambient dose equivalent with the results of the reference method of gold activation showed a very good agreement. For fast neutrons the results obtained with NEMUS will serve as reference values for this facility. The facility is ready for use as a thermal neutron reference field for calibrations of neutron measuring devices.


Assuntos
Algoritmos , Arquitetura de Instituições de Saúde , Laboratórios/normas , Nêutrons , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Teorema de Bayes , Calibragem , Doses de Radiação
3.
Radiat Prot Dosimetry ; 170(1-4): 78-81, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26715777

RESUMO

In 2012, the European Radiation Dosimetry Group (EURADOS) performed an intercomparison for neutron dosemeters that are intended to measure personal dose equivalent, Hp(10). A total of 31 participants registered with 34 dosimetry systems. The irradiation tests were chosen to provide the participants with useful information on their dosimetry systems, i.e. linearity, reproducibility, responses for different energies and angles and to simulated workplace fields. This paper gives details of the extensive information derived from the exercise.


Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/instrumentação , Calibragem , Europa (Continente) , Humanos , Modelos Lineares , Nêutrons , Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes
4.
Radiat Prot Dosimetry ; 170(1-4): 284-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26493946

RESUMO

A field-dependent correction factor can be obtained by comparing the readings of two albedo neutron dosemeters fixed in opposite directions on a polyethylene sphere to the H*(10) reading as determined with a thermal neutron detector in the centre of the same sphere. The work shows that the field calibration technique as used for albedo neutron dosemeters can be generalised for all kind of dosemeters, since H*(10) is a conservative estimate of the sum of the personal dose equivalents Hp(10) in two opposite directions. This result is drawn from reference values as determined by spectrometers within the EVIDOS project at workplace of nuclear installations in Europe. More accurate field-dependent correction factors can be achieved by the analysis of several personal dosimeters on a phantom, but reliable angular responses of these dosemeters need to be taken into account.


Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Carga Corporal (Radioterapia) , Calibragem , Humanos , Nêutrons , Imagens de Fantasmas , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Valores de Referência , Reprodutibilidade dos Testes , Local de Trabalho
5.
6.
Radiat Prot Dosimetry ; 161(1-4): 73-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24578527

RESUMO

The European Radiation Dosimetry Group (EURADOS) IC2012n intercomparison for neutron dosemeters intended to measure personal dose equivalent, Hp(10), was performed in 2012. A total of 31 participants (27 individual monitoring services from Europe, 2 from Japan, 1 from Israel and 1 from USA) registered with 34 dosimetry systems. Participation was restricted to passive or active neutron dosemeters routinely used in individual monitoring of radiation workers. The dosimetry systems were based on thermoluminescence, polyallyldiglycol carbonate, optically stimulated luminescence, fission track detection and silicon diodes (electronic devices). The irradiation tests were chosen to provide the participants with useful information on their dosimetry systems, i.e. linearity, reproducibility, responses for different energies and angles and to simulated workplace fields. The paper will report and discuss the first analysis of the results of the EURADOS IC2012n intercomparison.


Assuntos
Nêutrons , Radiometria/métodos , Irradiação Corporal Total , Eletrônica , Europa (Continente) , Humanos , Cooperação Internacional , Luminescência , Doses de Radiação , Radioisótopos/análise , Radiometria/instrumentação , Silício
7.
Radiat Prot Dosimetry ; 161(1-4): 352-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24403346

RESUMO

A new thermal neutron calibration facility based on a moderator assembly has been set up at PTB. It consists of 16 (241)Am-Be radionuclide sources mounted in a graphite block, 1.5 m wide, 1.5 m high and 1.8 m deep. The sources are distributed to eight different positions, at a mean distance of ∼1.25 m from the front face of the moderator. The neutron field at the reference position, 30 cm in front of the moderator device and 75 cm above the floor, has been characterised using calculations, Bonner sphere measurements and gold foil activation. First results are shown. The field is highly thermalised: 99 % in terms of fluence. It is quite homogenous within a 20 cm×20 cm area, but the absolute value of the thermal neutron fluence rate is small and yields an ambient dose equivalent rate of 3 µSv h(-1).


Assuntos
Calibragem , Nêutrons , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Radiometria/métodos , Amerício , Berílio , Cádmio , Desenho de Equipamento , Arquitetura de Instituições de Saúde , Germânio , Alemanha , Grafite , Incidência , Método de Monte Carlo , Reatores Nucleares , Imagens de Fantasmas , Polietileno , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Temperatura
8.
Radiat Prot Dosimetry ; 155(2): 125-40, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23241424

RESUMO

Electron storage rings of synchrotron light sources are typically filled only for several minutes day(-1). During these injections, the dose rates outside the shielding walls can be quite high even if the annual dose personal dose equivalent is below 1 mSv a(-1), which is the case at most synchrotron light sources. During the injection process, there is a time structure of short pulses (often defined by the convolution time of the synchrotron) having a pulse length of several 100 ns and a repetition rate between 1 and 10 Hz, which is defined by the acceleration processes in synchrotrons or linacs. Under these conditions, high measurement errors are possible, especially for neutron monitors that are based on proportional counters, which is the case for most commercially available neutron detectors. In this article, the authors' investigations of different neutron monitors are presented and how these results depend on the beam parameters, neutron fields and detector properties is shown. The experiments were conducted at the synchrotron light sources BESSYII and Metrology Light Source with pulsed electron beams of 1.7 GeV and 100 MeV, respectively. Other experiments were conducted at the HZB cyclotron with a 68-MeV pulsed proton beam that hits a spallation target. Fluka calculations of dose rates and neutron spectra were performed for the experiments. Correction formulas that are valid even in the saturation range were derived.


Assuntos
Elétrons , Nêutrons , Síncrotrons , Desenho de Equipamento , Método de Monte Carlo , Doses de Radiação
9.
Radiat Prot Dosimetry ; 126(1-4): 471-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17823130

RESUMO

The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those fields.


Assuntos
Ciclotrons , Modelos Biológicos , Nêutrons , Exposição Ocupacional/análise , Radiometria/métodos , Radiometria/tendências , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Masculino , Modelos Estatísticos , Doses de Radiação , Espanha
10.
Radiat Prot Dosimetry ; 125(1-4): 300-3, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17846030

RESUMO

Neutron survey instruments have been exposed at all the measurement locations used in the EVIDOS project. These results have an important impact in the interpretation of the results from the project, since operationally the survey instrument will be used for an initial assessment of and routine monitoring of the ambient dose equivalent dose rate. Additionally, since the response of these instruments is in some cases very well characterised, their systematic deviations from the reference quantities provide an important verification of the determination of those quantities.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Nêutrons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Radiat Prot Dosimetry ; 124(3): 219-29, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17890781

RESUMO

Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional Bonner sphere spectrometry and newly developed direction spectrometers. The results of the analysis, using Bayesian parameter estimation methods and different unfolding codes, some of them especially adapted to simultaneously unfold energy and direction distributions of the neutron fluence, showed that neutron spectra differed strongly at the different places, both in energy and direction distribution. The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discussed.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Monitoramento de Radiação/métodos , Análise Espectral/instrumentação , União Europeia , Humanos , Análise Espectral/métodos , Local de Trabalho
12.
Radiat Prot Dosimetry ; 124(3): 213-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17893081

RESUMO

Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H(p)(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Doses de Radiação , Monitoramento de Radiação/métodos , União Europeia , Humanos , Proteção Radiológica/métodos , Medição de Risco , Local de Trabalho
13.
Radiat Prot Dosimetry ; 125(1-4): 275-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17522043

RESUMO

Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive programme was devised to evaluate capabilities and limitations of standard and innovative personal dosemeters in relation to the mixed neutron-photon fields of concern to the nuclear industry. This paper describes the criteria behind the selection of dosimetry techniques and workplaces that were analysed, as well as the organisation of the measurement campaigns. Particular emphasis was placed on the evaluation of a variety of electronic personal dosemeters, either commercially available or previously developed by the partners. The estimates provided by these personal dosemeters were compared to reference values of dose equivalent quantities derived from spectrometry and fluence-to-dose equivalent conversion coefficients. Spectrometry was performed both with conventional multisphere and with some original instrumentation providing energy and direction resolution, based on silicon detectors and superheated drop detectors mounted on or in spherical moderators. The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europe.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , União Europeia , Internacionalidade , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiat Prot Dosimetry ; 126(1-4): 151-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17519241

RESUMO

Workplace neutron spectra from nuclear facilities obtained within the European project EVIDOS are compared with those of the simulated workplace fields CANEL and SIGMA and fields set-up with radionuclide sources at the PTB. Contributions of neutrons to ambient dose equivalent and personal dose equivalent are given in three energy intervals (for thermal, intermediate and fast neutrons) together with the corresponding direction distribution, characterised by three different types of distributions (isotropic, weakly directed and directed). The comparison shows that none of the simulated workplace fields investigated here can model all the characteristics of the fields observed at power reactors.


Assuntos
Exposição Ambiental/análise , Modelos Teóricos , Nêutrons , Reatores Nucleares , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Simulação por Computador , Europa (Continente) , Programas Governamentais , Doses de Radiação
15.
Radiat Prot Dosimetry ; 126(1-4): 487-90, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17519244

RESUMO

The results of measurements with neutron energies up to 60 MeV are shown for the personal neutron dosemeters Thermo Electron EPD-N2, ALOKA PDM-313 and the PTB prototype dosemeter DOS-2002. All dosemeters show dose equivalent responses that are about a factor of 10, too high at 60 MeV. A new prototype dosemeter-called DOS-2005-consisting of a detector with a thin effective layer of 6 microm has been set up at PTB. The dose equivalent response of this dosemeter and that of the newly developed dosemeter SAPHYDOSE-N was measured up to 19 MeV. Both dosemeters indicate a more flat response at high neutron energies. Further needs-optimisations, measurements and calculations-for use at high-energy accelerators and in space are discussed.


Assuntos
Eletrônica/instrumentação , Nêutrons , Exposição Ocupacional/análise , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Radiometria/tendências , Desenho de Equipamento , Análise de Falha de Equipamento , Previsões , Alemanha , Avaliação das Necessidades , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Radiat Prot Dosimetry ; 125(1-4): 293-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17449908

RESUMO

Within the EC project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'), different types of active neutron personal dosemeters (and some passive ones) were tested in workplace fields at nuclear installations in Europe. The results of the measurements which have been performed up to now are summarised and compared to our currently best estimates of the personal dose equivalent Hp(10). Under- and over-readings by more than a factor of two for the same dosemeter in different workplace fields indicate that in most cases the use of field-specific correction factors is required.


Assuntos
Desenho Assistido por Computador , Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Programas Governamentais , Internacionalidade , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Radiat Prot Dosimetry ; 125(1-4): 364-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17369265

RESUMO

Within the EC project EVIDOS, double-differential (energy and direction) fluence spectra were determined by means of novel direction spectrometers. By folding the spectra with fluence-to-dose equivalent conversion coefficients, contributions to H*(10) for 14 directions, and values of the personal dose equivalent Hp(10) and the effective dose E for 6 directions of a person's orientation in the field were determined. The results of the measurements and calculations obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e., at Krümmel (boiling water reactor and transport cask), at Mol (Venus research reactor and fuel facility Belgonucléaire) and at Ringhals (pressurised reactor and transport cask) are presented.


Assuntos
Carga Corporal (Radioterapia) , Modelos Biológicos , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Internacionalidade , Nêutrons , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Radiat Prot Dosimetry ; 125(1-4): 281-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17314086

RESUMO

The paper presents the main conclusions and recommendations derived from the EVIDOS project, which is supported by the European Commission within the 5th Framework Programme. EVIDOS aims at evaluating state of the art neutron dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This analysis complements a series of individual papers which present detailed results and it summarises the main findings from a practical point of view. Conclusions and recommendations are given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosemeter results.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , União Europeia , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Radiat Prot Dosimetry ; 125(1-4): 15-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17213218

RESUMO

The recommendations and test requests for the dose equivalent response of personal neutron dosemeters formulated by the new International Standard IEC 61526 are summarised. In particular, IEC 61526 allows the use of broad fields if dosemeters do not fulfil the hard requirements using monoenergetic neutrons. Some broad fields which can work as a replacement field using ISO sources (252Cf, 252Cf (D2O mod.), 241Am-Be) and simulated workplace fields (CANEL and SIGMA) are described. This work shows the results of recent measurements of the personal dose equivalent response for the dosemeters Thermo Electron EPD-N2, Aloka PDM-313 and the prototype dosemeter PTB DOS-2002, and discusses their compliance with respect to the new IEC 61526 standard.


Assuntos
Eletrônica/instrumentação , Fidelidade a Diretrizes/normas , Guias como Assunto , Nêutrons , Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Humanos , Internacionalidade , Exposição Ocupacional/prevenção & controle , Padrões de Referência , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Radiat Prot Dosimetry ; 125(1-4): 261-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-16980319

RESUMO

In 2001, the European Radiation Dosimetry Group, EURADOS, started a working group on 'Harmonisation of Individual Monitoring in Europe and the Dissemination of Information on New Techniques in this Field'. Within this group, one of the projects consisted of analysing the status of active personal dosemeters (APDs) in Europe. This paper reviews the regulatory requirements for APDs in 15 EU member states and summarises the main characteristics of commercial and new developments in this field. In particular, it focuses on the comparison of APD performance and standard passive dosimetry systems. Based on this information, an evaluation is initiated to establish why several countries are reluctant to accept APDs for dose records.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/normas , Proteção Radiológica/instrumentação , Proteção Radiológica/normas , Desenho de Equipamento/normas , Análise de Falha de Equipamento/normas , União Europeia , Humanos , Internacionalidade , Doses de Radiação , Monitoramento de Radiação/legislação & jurisprudência , Proteção Radiológica/legislação & jurisprudência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade