Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38673113

RESUMO

High-frequency transmission is limited to the skin depth in metals. Because poor conductivity cannot be compensated for by increasing the conductor thickness as with DC, optimal transport properties are prerequisites for radio frequency (RF) use. Structural and chemical analyses of transmission lines printed using a traditional ink consisting of Ag nanoflakes in a dispersing phase revealed that optimized thermal treatments yielded thorough burnout of the binder, significant grain growth, elimination of the pore volume, and electrical responses that were comparable to values obtained for thermally evaporated, fully dense Ag controls. Specifically, a low DC resistivity of 2.3 µΩ·cm (1.4× bulk Ag) and RF transmission coefficients of 0.87 and 0.75 at 5 GHz and 10 GHz, respectively, were measured in the nanoflake Ag prints. Conversely, in transmission lines printed from a metal-organic decomposition ink, residual chemical contamination impeded diffusion and densification, yielding greater porosity, small grains that are pinned, and a degraded RF response. Reasonably good porosity approximations were obtained from a model based on percolation theory. The results indicate that contaminants at interfaces and pore surfaces impede diffusion, pore elimination, and full densification, and further, alter carrier dynamics and degrade RF response.

2.
IEEE Trans Biomed Eng ; 66(1): 257-262, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993418

RESUMO

OBJECTIVE: In this paper, we investigate the impact of perfusion on the performance of microwave ablation across a large frequency range. METHODS: We designed multiple microwave ablation antennas to operate in liver tissue at discrete frequencies in the range 1.9-18 GHz. We performed electromagnetic simulations to calculate microwave power absorption patterns. Five-minute, 25 W ablation experiments were performed at each frequency in perfused and nonperfused ex vivo porcine livers, and thermal lesion dimensions were measured. RESULTS: The volume of greatest microwave power absorption shrinks by two orders of magnitude as the frequency is increased from 1.9 to 18 GHz. Mean thermal lesion volumes are consistent across the frequency range for a given perfusion state and are about three times smaller under active perfusion. Typical thermal lesion diameters (perpendicular to the antenna axis) were 24 mm and 16 mm for nonperfused and perfused ablations, respectively. No significant differences in axial ratio were observed among different frequency groups in active-perfusion experiments. CONCLUSION: Higher-frequency microwave ablation produces thermal lesions with volumes comparable to those achieved at lower frequencies, even in strongly perfused environments. SIGNIFICANCE: Higher-frequency microwave ablation is appealing because it allows for more flexibility in antenna design. A critical issue concerning the feasibility of higher frequency microwave ablation, considering its strong dependence on heat diffusion to grow thermal lesions, is its performance in strongly perfused environments. This paper shows that higher frequency microwave ablation achieves thermal lesions comparable to those from microwave ablation performed at conventional frequencies in both non- and strongly perfused environments.


Assuntos
Técnicas de Ablação/métodos , Fígado , Micro-Ondas , Perfusão/métodos , Animais , Simulação por Computador , Fígado/efeitos da radiação , Fígado/cirurgia , Suínos
3.
IEEE Trans Biomed Eng ; 61(6): 1702-10, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24845280

RESUMO

We demonstrate the feasibility of using high-frequency microwaves for tissue ablation by comparing the performance of a 10 GHz microwave ablation system with that of a 1.9 GHz system. Two sets of floating sleeve dipole antennas operating at these frequencies were designed and fabricated for use in ex vivo experiments with bovine livers. Combined electromagnetic and transient thermal simulations were conducted to analyze the performance of these antennas. Subsequently, a total of 16 ablation experiments (eight at 1.9 GHz and eight at 10.0 GHz) were conducted at a power level of 42 W for either 5 or 10 min. In all cases, the 1.9 and 10 GHz experiments resulted in comparable ablation zone dimensions. Temperature monitoring probes revealed faster heating rates in the immediate vicinity of the 10.0 GHz antenna compared to the 1.9 GHz antenna, along with a slightly delayed onset of heating farther from the 10 GHz antenna, suggesting that heat conduction plays a greater role at higher microwave frequencies in achieving a comparably sized ablation zone. The results obtained from these experiments agree very well with the combined electromagnetic/thermal simulation results. These simulations and experiments show that using lower frequency microwaves does not offer any significant advantages, in terms of the achievable ablation zones, over using higher frequency microwaves. Indeed, it is demonstrated that high-frequency microwave antennas may be used to create reasonably large ablation zones. Higher frequencies offer the advantage of smaller antenna size, which is expected to lead to less invasive interstitial devices and may possibly lead to the development of more compact multielement arrays with heating properties not available from single-element antennas.


Assuntos
Técnicas de Ablação/métodos , Fígado/efeitos da radiação , Fígado/cirurgia , Micro-Ondas/uso terapêutico , Animais , Bovinos , Estudos de Viabilidade , Modelos Teóricos