Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Res Cardiol ; 107(3): 222-232, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29098379

RESUMO

BACKGROUND: An influence of hydrostatic pressure on intracoronary indices of stenosis severity in vitro was recently reported. We sought to analyze the influence of hydrostatic pressure, caused by the height difference between the distal and proximal pressure sensor after guidewire positioning in the interrogated vessel, on intracoronary pressure measurements in vivo. METHODS AND RESULTS: In 30 coronary stenoses, intracoronary pressure measurements were performed in supine, left, and right lateral patient position. Height differences between the distal and proximal pressure sensor were measured by blinded observers. Measurement results of the position with the highest ("high") and lowest height difference ("low") were compared. In group "high", all measured indices were higher: mean difference of fractional flow reserve (FFR) 0.045 (SD 0.033, 95% CI 0.033-0.057, p < 0.0001), of instantaneous wave-free ratio (iFR) 0.043 (SD 0.04, 95% CI 0.029-0.057, p < 0.0001), and of resting Pd/Pa 0.037 (SD 0.034, 95% CI 0.025-0.049, p < 0.0001). Addition of the physically expectable hydrostatic pressure to the distal coronary pressures of the control group abolished the differences: corrected ∆FFR - 0.006 (SD 0.027, 95% CI - 0.015 to 0.004, p = 0.26), corrected ∆Pd/Pa - 0.008 (SD 0.03, 95% CI - 0.019 to 0.003, p = 0.18). Adjustment for hydrostatic pressure of FFR values in a standard supine position increased all values in anterior vessels and decreased all values in posterior vessels. The mean changes of FFR due to adjustment were: LAD - 0.048 (SD 0.016), CX 0.02 (SD 0.009), RCA 0.02 (SD 0.021). Dichotomous severity classification changed in 12.9% of stenoses. CONCLUSIONS: The study demonstrates a relevant influence of hydrostatic pressure on intracoronary indices of stenosis severity in vivo, caused by the height differences between distal and proximal pressure sensor.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Pressão Hidrostática , Cateterismo Cardíaco/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
3.
JACC Cardiovasc Interv ; 10(8): 764-773, 2017 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-28365266

RESUMO

OBJECTIVES: The authors sought to analyze height differences within the coronary artery tree in patients in a supine position and to quantify the impact of hydrostatic pressure on intracoronary pressure measurements in vitro. BACKGROUND: Although pressure equalization of the pressure sensor and the systemic pressure at the catheter tip is mandatory in intracoronary pressure measurements, subsequent measurements may be influenced by hydrostatic pressure related to the coronary anatomy in the supine position. Outlining and quantifying this phenomenon is important to interpret routine and pullback pressure measurements within the coronary tree. METHODS: Coronary anatomy was analyzed in computed tomography angiographies of 70 patients to calculate height differences between the catheter tip and different coronary segments in the supine position. Using a dynamic pressure simulator, the effect of the expected hydrostatic pressure resulting from such height differences on indices stenosis severity was assessed. RESULTS: In all patients, the left anterior and right posterior descending arteries are the highest points of the coronary tree with a mean height difference of -4.9 ± 1.6 cm and -3.8 ± 1.0 cm; whereas the circumflex artery and right posterolateral branches are the lowest points, with mean height differences of 3.9 ± 0.9 cm and 2.6 ± 1.6 cm compared with the according ostium. In vitro measurements demonstrated a correlation of the absolute pressure differences with height differences (r = 0.993; p < 0.0001) and the slope was 0.77 mm Hg/cm. The Pd/Pa ratio and instantaneous wave-free ratio correlated also with the height difference (fractional flow reserve r = 0.98; p < 0.0001; instantaneous wave-free ratio r = 0.97; p < 0.0001), but both were influenced by the systemic pressure level. CONCLUSIONS: Hydrostatic pressure variations resulting from normal coronary anatomy in a supine position influence intracoronary pressure measurements and may affect their interpretation during stenosis severity assessment.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária/métodos , Circulação Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Pressão Hidrostática , Masculino , Modelos Anatômicos , Modelos Cardiovasculares , Posicionamento do Paciente , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Decúbito Dorsal , Transdutores de Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...