Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Des Devel Ther ; 14: 961-967, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32184565

RESUMO

OBJECTIVE: This study aimed to quantify the amount of perindopril and its active metabolite perindoprilat present in breast milk and corresponding maternal and infant plasma concentrations. DESIGN: Prospective, longitudinal, observational. SETTING: Tertiary specialist paediatric and obstetric hospital in Adelaide, South Australia. POPULATION: Breastfeeding women actively treated with perindopril for hypertensive disorders postpartum. METHODS: Eight breast milk samples and a single plasma sample were collected from each participant over a 24 hrs period, and plasma samples were taken from eligible breastfed infants. Breast milk and plasma concentrations of perindopril and perindoprilat were analysed using a validated Liquid Chromatography tandem-Mass Spectrometry (LC-MS/MS) method. MAIN OUTCOME MEASURES: Mean breast milk concentrations of perindopril and perindoprilat, Relative Infant Dose (RID) <10%, and Theoretical Infant Dose (TID). RESULTS: Ten women and three infants participated in the study. The mean concentration of perindopril in breast milk for each participant ranged from 0.003 to 1.2 ng/mL and perindoprilat 0.2-36 ng/mL. RID for perindopril was 0.0005-0.2% and perindoprilat 0.03-4.6%. TID for perindopril was 0.00045-0.18 µg/kg/day and perindoprilat 0.032-5.4 µg/kg/day. Infant plasma levels for perindopril ranged from 0.44 to 1.12 ng/mL and perindoprilat undetectable - 10.14 ng/mL. Maternal reports described normal infant growth and development. CONCLUSION: Infant exposure to perindopril and perindoprilat through breast milk is low. However, some infants were found to have plasma perindoprilat concentrations consistent with pharmacodynamic effects. Perindopril may be used in mothers of healthy term infants, provided the infant is carefully monitored.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/sangue , Leite Humano/química , Perindopril/sangue , Adulto , Aleitamento Materno/efeitos adversos , Feminino , Humanos , Indóis/sangue , Indóis/farmacocinética , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
2.
Drug Des Devel Ther ; 12: 3645-3651, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30464396

RESUMO

INTRODUCTION: Rosuvastatin reduces concentrations of total cholesterol (TC) and is used for the management of hypercholesterolemia and prevention of acute coronary syndromes. There are no published reports estimating infant exposure to rosuvastatin through breast milk. PURPOSE: The aims of this study were to quantify concentrations of rosuvastatin in human milk and plasma from a lactating woman taking rosuvastatin and to investigate potential infant exposure. MATERIALS AND METHODS: A 38-year-old breastfeeding mother was commenced on rosuvastatin 20 mg daily for secondary prevention of an acute coronary syndrome. Eight maternal breast milk samples and a single plasma sample were collected over a 24-hour period. The samples were quantified using a sensitive liquid chromatography-mass spectrometry (LC-MS/MS) method. RESULTS: The average concentration of rosuvastatin in breast milk was 30.84 ng/mL, and a peak concentration of 58.59 ng/mL occurred at 17 hours after oral administration. Although the milk-to-plasma (M/P) ratio was 16.49 at 14 hours, the theoretical infant dosage (TID) and relative infant dose (RID) were 0.005 mg/kg/day and 1.50%, respectively. CONCLUSION: The findings suggest that only small amounts of rosuvastatin pass into breast milk. Should the maternal condition necessitate treatment, consideration could be given to the use of rosuvastatin during breastfeeding provided the infant is monitored.


Assuntos
Leite Humano/química , Rosuvastatina Cálcica/análise , Administração Oral , Adulto , Cromatografia Líquida , Feminino , Humanos , Controle de Qualidade , Rosuvastatina Cálcica/administração & dosagem
3.
J Hum Lact ; 34(3): 592-599, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29870669

RESUMO

BACKGROUND: Atenolol lactation information is limited, and controversy exists over the safety of its use during breastfeeding. In this study, important parameters including milk-to-plasma ratio, ratio of infant plasma to maternal plasma, infant daily dosage, and relative infant dose were investigated. The findings from this study add information to existing data about atenolol transfer in human milk. This may help guide health professionals in decision making regarding the safety of beta blockers used by mothers during breastfeeding. Research aim: The aims of the study were to quantify concentrations of atenolol in human plasma and milk, to evaluate atenolol pharmacokinetics in lactating women, and to investigate subsequent infant exposure to atenolol via mother's milk. METHODS: In this prospective, longitudinal observational study, participants were lactating mothers ( N = 3), 1 to 4 months postpartum, who had been taking atenolol for therapeutic reasons, and one 4-month-old breastfed infant. Eight milk samples were collected over 24 hr at different time points, together with a single blood sample from each lactating mother and the infant, and quantified using a new sensitive liquid chromatography mass spectrometry method developed for this study. RESULTS: Peak milk concentrations of atenolol were observed in the women at 4 hr (Tmax) after oral administration. The dose-normalized maximum concentrations (Cmax) of all patients were similar. The mean milk-to-plasma ratio of the patients who were taking 25 to 100 mg of atenolol was 8.57%. In the mother-infant pair study, the ratio (%) of infant plasma drug concentration to maternal plasma drug concentration observed (18.87%) was similar to the relative infant dose estimated (18.20%). The relative infant dose values (13.96%-18.20%) for all patients were within 10% to 25% of maternal dosage. CONCLUSION: Atenolol use during breastfeeding should be undertaken with some precaution. If clinically indicated, an alternate beta blocker may be preferred.


Assuntos
Atenolol/análise , Lactação/efeitos dos fármacos , Leite Humano/química , Adulto , Atenolol/sangue , Atenolol/uso terapêutico , Aleitamento Materno/efeitos adversos , Relação Dose-Resposta a Droga , Feminino , Humanos , Lactente , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas/estatística & dados numéricos , Lactação/sangue , Estudos Longitudinais , Leite Humano/metabolismo , Período Pós-Parto/sangue , Período Pós-Parto/metabolismo , Estudos Prospectivos
4.
Am J Health Syst Pharm ; 75(5): 309-315, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29472513

RESUMO

PURPOSE: Results of a study to determine the stability of an extemporaneously compounded minoxidil oral suspension under various temperature and stress conditions are reported. METHODS: Commercially available minoxidil tablets (10 mg) were crushed to a fine powder, and predetermined amounts of 2 suspending vehicles were added to produce a 1-mg/mL suspension, which was stored in glass bottles at room temperature (25 ± 2 °C) or in a refrigerator (4 ± 2 °C). To simulate daily patient use, 5 days weekly 1 bottle of the suspension was removed from refrigerated storage and shaken and 0.5 mL of the contents discarded. At each specified time point, samples were analyzed in duplicate (n = 6 for each test condition) using a validated high-performance liquid chromatography method. Samples were visually observed and their pH measured at each time point. Microbiological studies were performed on day 0 and at week 24. RESULTS: The mean percentage of initial minoxidil concentration remaining in all refrigerated samples exceeded 90% throughout the 24-week study, with no change in appearance, pH, microbial activity, odor, or redispersibility. During storage at room temperature, the suspension exhibited a color change at week 4, with slight sedimentation after 6 weeks, although minoxidil recovery exceeded 90% for 10 weeks. CONCLUSION: An extemporaneously compounded minoxidil oral suspension was stable for 24 weeks when stored in a refrigerator. This suspension can be used for up to 3 weeks when stored at room temperature.


Assuntos
Anti-Hipertensivos/análise , Anti-Hipertensivos/normas , Composição de Medicamentos/normas , Minoxidil/análise , Minoxidil/normas , Administração Oral , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Composição de Medicamentos/métodos , Estabilidade de Medicamentos , Armazenamento de Medicamentos/métodos , Armazenamento de Medicamentos/normas , Suspensões
5.
Anal Bioanal Chem ; 409(26): 6141-6148, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28842738

RESUMO

A first of its kind, simple, rapid, and sensitive liquid chromatography mass spectrometry (LC-MS/MS) method was developed and validated for quantification of perindopril and perindoprilat in both human plasma and breast milk. The analytes and internal standards (phenazone and acetyl salicylic acid) were extracted from biological matrices by protein precipitation. A Phenomenex® C-18 column was used to provide an appropriate chromatographic separation of the analytes, followed by detection with tandem mass spectrometry. Gradient chromatographic and mass spectrometric detection conditions with mobile phases (A: 5% methanol + 0.1% formic acid in water v/v, and B: 95% methanol + 0.1% formic acid in water v/v) were developed to achieve a LOQ of 0.5 ng/mL in both human plasma and milk. The method was suitable of evaluating clinical samples. The mass transition was followed as m/z 369.10/172.00 for perindopril, m/z 339.00/168.10 for perindoprilat, m/z 188.90/55.95 for phenazone, and m/z 179.04/137.02 for acetyl salicylic acid. The developed method was optimized and validated with a linear range of 0.1-200 ng/mL (r 2 = better than 0.99 for both perindopril and perindoprilat). The precision and accuracy values were within 15% CV. The overall recovery of the analytes was 80-110%. The method has good specificity and repeatability. Stability studies were conducted in both human plasma and bovine milk for up to 3 months, at the storage conditions of 25, 4, and -80 °C.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Inibidores da Enzima Conversora de Angiotensina/sangue , Indóis/análise , Indóis/sangue , Leite Humano/química , Perindopril/análise , Perindopril/sangue , Aleitamento Materno , Cromatografia Líquida/economia , Cromatografia Líquida/métodos , Feminino , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/métodos
7.
Biomicrofluidics ; 4(3): 32205, 2010 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21045921

RESUMO

Building on recent breakthroughs in the field of microfluidic-based capture of rare cancer cells circulating in the blood, the present article reports on the use of Herceptin functionalized PDMS devices designed to efficiently capture from blood cancer cells, overexpressing the tyrosine kinase human epidermal growth factor receptor (HER2). The identification of patients overexpressing HER2 is critical as it typically associates with an aggressive disease course in breast cancer and poor prognosis. Importantly, HER2 positive patients have been found to significantly benefit from Herceptin (Trastuzumab), a humanized monoclonal antibody (MAb) against HER2. Disposable PDMS devices prepared using standard soft lithography were functionalized by the plasma polymerization of an epoxy-containing monomer. The epoxy-rich thin film (AGEpp) thus created could be conjugated with Herceptin either directly or through a polyethylene glycol interlayer. The properties and reactivity toward the monoclonal antibody conjugation of these coatings were determined using x-ray photoelectron spectroscopy; direct conjugation provided a good compromise in reactivity and resistance to biologically nonspecific fouling and was selected. Using the breast cancer cell line SK-BR-3 as a model for cells overexpressing HER2, the immunocapture efficacy of the Herceptin functionalized PDMS was demonstrated in model studies. Validation studies confirmed the ability of the device to efficiently capture (∼80% capture yield) HER2 positive cells from full blood.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...