Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
1.
Bone Joint J ; 101-B(7_Supple_C): 48-54, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31256639

RESUMO

AIMS: The outcomes of total knee arthroplasty (TKA) depend on many factors. The impact of implant design on patient-reported outcomes is unknown. Our goal was to evaluate the patient-reported outcomes and satisfaction after primary TKA in patients with osteoarthritis undergoing primary TKA using five different brands of posterior-stabilized implant. PATIENTS AND METHODS: Using our institutional registry, we identified 4135 patients who underwent TKA using one of the five most common brands of implant. These included Biomet Vanguard (Zimmer Biomet, Warsaw, Indiana) in 211 patients, DePuy/Johnson & Johnson Sigma (DePuy Synthes, Raynham, Massachusetts) in 222, Exactech Optetrak Logic (Exactech, Gainesville, Florida) in 1508, Smith & Nephew Genesis II (Smith & Nephew, London, United Kingdom) in 1415, and Zimmer NexGen (Zimmer Biomet) in 779 patients. Patients were evaluated preoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Lower Extremity Activity Scale (LEAS), and 12-Item Short-Form Health Survey questionnaire (SF-12). Demographics including age, body mass index, Charlson Comorbidity Index, American Society of Anethesiologists status, sex, and smoking status were collected. Postoperatively, two-year KOOS, LEAS, SF-12, and satisfaction scores were compared between groups. RESULTS: Outcomes were available for 4069 patients (98%) at two years postoperatively. In multiple regression analysis, which separately compared each implant group with the aggregate of all others, there were no clinically significant differences in the change of KOOS score from baseline to two-year follow-up between any of the groups. More than 80% of patients in each group were satisfied at this time in all domains. In a multivariate regression model, patients in the NexGen group were the most likely to be satisfied (odds ratio (OR) 1.63; p = 0.006) and Optetrak Logic patients were the least likely to be satisfied (OR 0.60; p < 0.001). CONCLUSION: TKA provides improvement in function and satisfaction regardless of the type of implant. We could not demonstrate superiority of one design above others across these groups of implants, and any price premium for one above the other systems may not be justified. Healthcare administrators may find these similarities in outcomes helpful when negotiating purchasing contracts. Cite this article: Bone Joint J 2019;101-B(7 Supple C):48-54.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica/fisiologia , Idoso , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/fisiopatologia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
2.
Bone Joint J ; 101-B(6_Supple_B): 68-76, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31146558

RESUMO

AIMS: Custom flange acetabular components (CFACs) are a patient-specific option for addressing large acetabular defects at revision total hip arthroplasty (THA), but patient and implant characteristics that affect survivorship remain unknown. This study aimed to identify patient and design factors related to survivorship. PATIENTS AND METHODS: A retrospective review of 91 patients who underwent revision THA using 96 CFACs was undertaken, comparing features between radiologically failed and successful cases. Patient characteristics (demographic, clinical, and radiological) and implant features (design characteristics and intraoperative features) were collected. There were 74 women and 22 men; their mean age was 62 years (31 to 85). The mean follow-up was 24.9 months (sd 27.6; 0 to 116). Two sets of statistical analyses were performed: 1) univariate analyses (Pearson's chi-squared and independent-samples Student's t-tests) for each feature; and 2) bivariable logistic regressions using features identified from a random forest analysis. RESULTS: Radiological failure and revision rates were 23% and 12.5%, respectively. Revisions were undertaken at a mean of 25.1 months (sd 26.4) postoperatively. Patients with radiological failure were younger at the time of the initial procedure, were less likely to have a diagnosis of primary osteoarthritis (OA), were more likely to have had ischial screws in previous surgery, had fewer ischial screw holes in their CFAC design, and had more proximal ischial fixation. Random forest analysis identified the age of the patient and the number of locking and non-locking screws used for inclusion in subsequent bivariable logistic regression, but only age (odds ratio 0.93 per year) was found to be significant. CONCLUSION: We identified both patient and design features predictive of CFAC survivorship. We found a higher rate of failure in younger patients, those whose primary diagnosis was not OA, and those with more proximal ischial fixation or fewer ischial fixation options. Cite this article: Bone Joint J 2019;101-B(6 Supple B):68-76.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Parafusos Ósseos , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
Bone Joint J ; 97-B(5): 662-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25922461

RESUMO

The foot and ankle outcome score (FAOS) has been evaluated for many conditions of the foot and ankle. We evaluated its construct validity in 136 patients with osteoarthritis of the ankle, its content validity in 37 patients and its responsiveness in 39. Data were collected prospectively from the registry of patients at our institution. All FAOS subscales were rated relevant by patients. The Pain, Activities of Daily Living, and Quality of Life subscales showed good correlation with the Physical Component score of the Short-Form-12v2. All subscales except Symptoms were responsive to change after surgery. We concluded that the FAOS is a weak instrument for evaluating osteoarthritis of the ankle. However, some of the FAOS subscales have relative strengths that allow for its limited use while we continue to seek other satisfactory outcome instruments.


Assuntos
Articulação do Tornozelo , Osteoartrite/cirurgia , Inquéritos e Questionários , Adulto , Idoso , Feminino , , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Adulto Jovem
4.
Clin Exp Rheumatol ; 32(6 Suppl 86): S-189-93, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25152211

RESUMO

OBJECTIVES: We aimed to assess the long-term safety and tolerability of imatinib in diffuse cutaneous systemic sclerosis (dcSSc). METHODS: In this open-label, single-arm, extension-phase clinical trial, patients continued imatinib for 24 months following 12 months of initial treatment. RESULTS: Seventeen patients were enrolled. Forty of 92 adverse events (AE) and 0/6 serious (S) AEs were possibly related to medication. The MRSS decreased from a median of 21 to 16, (p=0.002). CONCLUSIONS: This study demonstrates long-term safety and tolerability of imatinib in a substantial proportion of patients with dcSSc. This is important in evaluating the relevance of this therapy in a chronic disease such as SSc.


Assuntos
Benzamidas/uso terapêutico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Piperazinas/uso terapêutico , Inibidores de Proteínas Quinases/uso terapêutico , Pirimidinas/uso terapêutico , Esclerodermia Difusa/tratamento farmacológico , Adulto , Antirreumáticos/uso terapêutico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Quimioterapia Combinada , Feminino , Glucocorticoides/uso terapêutico , Humanos , Hidroxicloroquina/uso terapêutico , Mesilato de Imatinib , Doenças Pulmonares Intersticiais/etiologia , Masculino , Pessoa de Meia-Idade , Prednisona/uso terapêutico , Inibidores da Bomba de Prótons/uso terapêutico , Testes de Função Respiratória , Esclerodermia Difusa/complicações , Resultado do Tratamento
5.
Lupus ; 23(3): 293-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24316605

RESUMO

OBJECTIVE: Rising anti-double-stranded (ds) DNA titers have been shown by some, but not all, studies to be predictive of disease flares in systemic lupus erythematosus (SLE). We hypothesized that a rapid and substantial rise in anti-dsDNA titer (anti-dsDNA surge) would be a good predictor of a clinically important SLE flare. METHODS: A matched case-control study was conducted in an academic rheumatology practice setting. Our primary endpoint was the occurrence of a severe SELENA-SLEDAI (SS) flare within six months of an anti-dsDNA surge, and secondary endpoints were mild/moderate SS flares, as well as BILAG A and B renal flares. Cases were identified as those patients whose disease course included a surge of anti-dsDNA, defined as an increase of anti-dsDNA titer by the Crithidia luciliae immunofluorescence (CLIF) assay from 0 to 3+/4+, or from 1+ to 4+, within a period of less than 12 months. The date of the anti-dsDNA surge was defined as Day 0. Two control SLE patients were identified for each case and were matched for age, sex, race, and visit date closest to case Day 0, but without an anti-dsDNA surge. Logistic regression models were used to detect associations between anti-dsDNA surges and severe SS flares. RESULT: A higher proportion of cases, compared to controls, experienced a severe SS flare within six months of Day 0 (OR 6.3 (95% confidence intervals 2.0-19.9), p = 0.02). Associations with all flares and hospitalizations for flares were also observed. However, an anti-dsDNA surge was not predictive of a renal flare. CONCLUSION: An anti-dsDNA surge predicts the subsequent development of a severe SS flare within six months. Physicians should closely monitor such patients and treat promptly at the first sign of clinical activity.


Assuntos
Anticorpos Antinucleares/sangue , DNA/imunologia , Lúpus Eritematoso Sistêmico/imunologia , Nefrite Lúpica/imunologia , Centros Médicos Acadêmicos , Adulto , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Progressão da Doença , Feminino , Imunofluorescência , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Lúpus Eritematoso Sistêmico/sangue , Lúpus Eritematoso Sistêmico/diagnóstico , Nefrite Lúpica/sangue , Nefrite Lúpica/diagnóstico , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Regulação para Cima , Adulto Jovem
6.
Environ Sci Technol ; 47(13): 7277-84, 2013 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-23441676

RESUMO

The Reno Atmospheric Mercury Intercomparison Experiment (RAMIX) was in Reno, NV from August 22, 2011 to September 16, 2011. The goals of the experiment were to compare existing and new methods for measurements of ambient elemental and oxidized Hg, and to test these with quantitative spikes of Hg(0), HgBr2, O3 and water vapor. In this paper we describe the design, testing, and deployment of a high flow manifold system designed to deliver ambient air and spiked compounds to multiple instruments simultaneously. The manifold was constructed of 1" OD PFA tubing and heated to 115 °C for the entire active zone. Manifold flow was controlled at ∼200 LPM using a blower and a velocity sensor in a feedback control system. Permeation tubes in controlled ovens were used to deliver Hg(0) and HgBr2. Ozone was generated from a small UV lamp in a flow of high purity O2. Water vapor was generated by pumping a flow of purified N2 through heated, high purity water. The spiking delivery for Hg(0), HgBr2, O3, and water vapor after dilution in the manifold ranged up to 20 ng m(-3), 0.64 ng m(-3), 100 ppbv, and 20 g kg(-1), respectively. During laboratory tests the average transmission efficiencies for Hg(0), HgBr2, and O3 were found to be 92%, 76%, and 93%, respectively.


Assuntos
Poluentes Atmosféricos/análise , Brometos/análise , Monitoramento Ambiental/instrumentação , Compostos de Mercúrio/análise , Mercúrio/análise , Monitoramento Ambiental/métodos , Desenho de Equipamento , Nevada , Oxirredução , Ozônio/análise , Água/análise
7.
J Bone Joint Surg Br ; 94(9): 1209-15, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22933492

RESUMO

Component malalignment can be associated with pain following total knee replacement (TKR). Using MRI, we reviewed 50 patients with painful TKRs and compared them with a group of 16 asymptomatic controls to determine the feasibility of using MRI in evaluating the rotational alignment of the components. Using the additional soft-tissue detail provided by this modality, we also evaluated the extent of synovitis within these two groups. Angular measurements were based on the femoral transepicondylar axis and tibial tubercle. Between two observers, there was very high interobserver agreement in the measurements of all values. Patients with painful TKRs demonstrated statistically significant relative internal rotation of the femoral component (p = 0.030). There was relative internal rotation of the tibial to femoral component and combined excessive internal rotation of the components in symptomatic knees, although these results were significant only with one of the observers (p = 0.031). There was a statistically significant association between the presence and severity of synovitis and painful TKR (p < 0.001). MRI is an effective modality in evaluating component rotational alignment.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Dor Pós-Operatória/etiologia , Sinovite/diagnóstico , Sinovite/etiologia , Idoso , Idoso de 80 Anos ou mais , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Rotação
8.
Knee Surg Sports Traumatol Arthrosc ; 19(10): 1693-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21431375

RESUMO

PURPOSE: Lower extremity alignment is an important consideration prior to cartilage surgery and/or osteotomy about the knee. This is measured on full length standing hip to ankle radiographs, which has traditionally been done using hard copy radiographs. However, the advent of PACS (Picture Archiving and Communication Systems) has allowed these measurements to be done on computer based digital radiographs. The objectives of this study were to evaluate the intra- and inter-observer reliability of lower limb alignment measures manually obtained from hard copy radiographs versus using the Philips Easy Vision system, and to assess the subjective ease of use for the two methods. METHODS: Forty-two patients who underwent surgery and who had a standing hip to ankle radiograph on file were identified. Four raters, including two radiologists and two orthopaedic surgeons, measured each hard copy radiograph and computer image on two separate occasions. Three measurements were recorded for each hard copy radiograph and computer image-width of tibial plateau, the distance from the medial aspect of the tibial plateau to the weight-bearing line, and the mechanical axis. RESULTS: All correlations for this study were high. For tibial plateau data, the hard copy radiographs compared to PACS demonstrated intra-class correlation coefficients (ICC) ranging from 0.93 to 0.99 for inter-rater reliability for the four raters. The ICC for intra-rater reliability for hard copies ranged from 0.90 to 0.99 and for PACS from 0.94 to 0.99. The inter-rater data comparing raters ranged from 0.87 to 0.98 for hard copy radiographs and from 0.98 to 0.99 for PACS. For mechanical axis data, the ICC for hard copy radiograph compared to PACS ranged from 0.93 to 0.97 for the intra-rater reliability for the four raters. The intra-rater reliability for mechanical axis data on hard copy radiograph ranged from an ICC of 0.86 to 0.96, and for PACS the ICC ranged from 0.93 to 0.99. The inter-observer data for hard copy radiographs using the mechanical axis ranged from 0.88 to 0.94 and for PACS ranged from 0.93 to 0.97. The physicians rated PACS as statistically significantly easier to use when compared to hard copy (P = 0.03). CONCLUSION: Evaluation of lower extremity alignment using two techniques prior to knee surgery was found to have higher inter- and intra-observer reliability using PACS software. PACS is now used prior to cartilage surgery and/or osteotomy to measure both alignment and the location of the weight bearing line on the tibial plateau both before and after surgery. LEVEL OF EVIDENCE: Diagnostic study, Level I.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Sistemas de Informação em Radiologia , Tíbia/diagnóstico por imagem , Articulação do Tornozelo/anatomia & histologia , Feminino , Articulação do Quadril/anatomia & histologia , Humanos , Articulação do Joelho/anatomia & histologia , Variações Dependentes do Observador , Radiografia , Reprodutibilidade dos Testes , Tíbia/anatomia & histologia
9.
J Bone Joint Surg Br ; 93(1): 47-51, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21196542

RESUMO

Pulmonary embolism is a serious complication after arthroscopy of the knee, about which there is limited information. We have identified the incidence and risk factors for symptomatic pulmonary embolism after arthroscopic procedures on outpatients. The New York State Department of Health Statewide Planning and Research Cooperative System database was used to review arthroscopic procedures of the knee performed on outpatients between 1997 and 2006, and identify those admitted within 90 days of surgery with an associated diagnosis of pulmonary embolism. Potential risk factors included age, gender, complexity of surgery, operating time defined as the total time that the patient was actually in the operating room, history of cancer, comorbidities, and the type of anaesthesia. We identified 374,033 patients who underwent 418,323 outpatient arthroscopies of the knee. There were 117 events of pulmonary embolism (2.8 cases for every 10 000 arthroscopies). Logistic regression analysis showed that age and operating time had significant dose-response increases in risk (p < 0.001) for a subsequent admission with a pulmonary embolism. Female gender was associated with a 1.5-fold increase in risk (p = 0.03), and a history of cancer with a threefold increase (p = 0.05). These risk factors can be used when obtaining informed consent before surgery, to elevate the level of clinical suspicion of pulmonary embolism in patients at risk, and to establish a rationale for prospective studies to test the clinical benefit of thromboprophylaxis in high-risk patients.


Assuntos
Artroscopia/efeitos adversos , Articulação do Joelho/cirurgia , Embolia Pulmonar/etiologia , Adolescente , Adulto , Fatores Etários , Idoso , Anestesia/métodos , Artroscopia/estatística & dados numéricos , Métodos Epidemiológicos , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , New York/epidemiologia , Ambulatório Hospitalar , Embolia Pulmonar/epidemiologia , Fatores Sexuais , Adulto Jovem
10.
Int J Sports Med ; 30(9): 663-7, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19585403

RESUMO

Gender differences in hip and core strength and range of motion may contribute to the gender based variance in injury risk. This study was designed to test the primary hypothesis that hip and core strength, flexibility and lower extremity dynamic alignment differ in male and female soccer athletes. Ninety-eight collegiate soccer players (54 male, 44 female) participated in this study. Athletes were evaluated for hip range of motion, and hip and abdominal strength. Both male and female soccer players demonstrated limited hip rotation, with less hip internal rotation in males (p<0.0001), and poor abdominal core control, although the males are stronger (p=0.02). Overall hip ROM is shifted towards internal rotation in females compared to males. Female soccer players also have a significant side-to-side disparity in hip abductor strength (p<0.0001), not present in males. The shift in hip ROM towards internal rotation combined with the hip abductor imbalance may be associated with a position of ACL risk with internally rotated hips and valgus knees in female soccer players. Limitations in hip and core strength and range of motion may play a role in the disparity between the male and female rate of ACL injury.


Assuntos
Músculos Abdominais/fisiologia , Articulação do Quadril/fisiologia , Amplitude de Movimento Articular/fisiologia , Futebol/fisiologia , Adolescente , Lesões do Ligamento Cruzado Anterior , Feminino , Humanos , Articulação do Joelho/fisiologia , Masculino , Risco , Rotação , Fatores Sexuais , Adulto Jovem
11.
Osteoporos Int ; 20(8): 1353-62, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19066707

RESUMO

SUMMARY: Recent evidence has linked long-term bisphosphonate use with insufficiency fractures of the femur in postmenopausal women. In this case-control study, we have identified a significant association between a unique fracture of the femoral shaft, a transverse fracture in an area of thickened cortices, and long-term bisphosphonate use. Further studies are warranted. INTRODUCTION: Although clinical trials confirm the anti-fracture efficacy of bisphosphonates over 3-5 years, the long-term effects of bisphosphonate use on bone metabolism are unknown. Femoral insufficiency fractures in patients on prolonged treatment have been reported. METHODS: We performed a retrospective case-control study of postmenopausal women who presented with low-energy femoral fractures from 2000 to 2007. Forty-one subtrochanteric and femoral shaft fracture cases were identified and matched by age, race, and body mass index to one intertrochanteric and femoral neck fracture each. RESULTS: Bisphosphonate use was observed in 15 of the 41 subtrochanteric/shaft cases, compared to nine of the 82 intertrochanteric/femoral neck controls (Mantel-Haenszel odds ratio (OR), 4.44 [95% confidence interval (CI) 1.77-11.35]; P = 0.002). A common X-ray pattern was identified in ten of the 15 subtrochanteric/shaft cases on a bisphosphonate. This X-ray pattern was highly associated with bisphosphonate use (OR, 15.33 [95% CI 3.06-76.90]; P < 0.001). Duration of bisphosphonate use was longer in subtrochanteric/shaft cases compared to both hip fracture controls groups (P = 0.001). CONCLUSIONS: We found a significantly greater proportion of patients with subtrochanteric/shaft fractures to be on long-term bisphosphonates than intertrochanteric/femoral neck fractures. Bisphosphonate use was highly associated with a unique X-ray pattern. Further studies are warranted.


Assuntos
Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/efeitos adversos , Fraturas do Fêmur/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Conservadores da Densidade Óssea/administração & dosagem , Estudos de Casos e Controles , Difosfonatos/administração & dosagem , Esquema de Medicação , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/etiologia , Fraturas do Colo Femoral/induzido quimicamente , Fraturas do Colo Femoral/etiologia , Humanos , Osteoporose Pós-Menopausa/complicações , Osteoporose Pós-Menopausa/tratamento farmacológico , Radiografia
12.
Int Orthop ; 30(4): 243-7, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16683113

RESUMO

The role of surface finish on the survivorship of cemented femoral stems continues to be debated. A total of 34 proximally roughened cemented stems were implanted in 33 consecutive patients undergoing total hip arthroplasty by a single surgeon. An alarmingly high failure rate was observed, prompting a retrospective chart review, analysis of radiographs, and evaluation of retrieved stems and pathological specimens. Nineteen patients were available with more than two years follow-up. Of these 19 patients, nine stems had failed (47%) due to severe osteolysis and stem loosening. Failures were significantly more common in the male gender (p<0.005), and young (p=0.05), tall (p<0.002), and heavy patients (p<0.004). All failed revised hips showed severe metallosis, with both gross and microscopic evidence of metallic shedding from the stems. Our findings suggest that this proximally roughened stem is susceptible to early failure. Failure is characterized by stem debonding, subsidence within the cement mantle, shedding of metallic and cement particles due to fretting, and rapidly progressive osteolysis. These findings have been observed with other rough surface finish cemented stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
13.
Inj Prev ; 8(2): 116-20, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12120829

RESUMO

OBJECTIVES: Older drivers have become a larger part of the driving population and will continue to do so as the baby boomers reach retirement age. The purpose of this study was to identify the potential effects of this population increase on highway safety. METHODS: Driver involvement rates for all police reported crashes were calculated per capita, per licensed driver, and per vehicle-mile of travel for 1990 and 1995. Also, driver involvement rates for fatal crashes were calculated for 1983, 1990, and 1995. Based on current crash rates per licensed driver and estimates of the future number of licensed drivers, projections of crashes involving drivers aged 65 and older were made for years 2010, 2020, and 2030. RESULTS: Driver crash involvement rates per capita decreased with age, but fatal involvement rates per capita increased starting at age 70. The same pattern existed for involvement rates per licensed driver. For both all crashes and fatal crashes, involvement rates per mile driven increased appreciably at age 70. Using projections of population growth, it was estimated that for all ages there will be a 34% increase in the number of drivers involved in police reported crashes and a 39% increase in the number involved in fatal crashes between 1999 and 2030. In contrast, among older drivers, police reported crash involvements are expected to increase by 178% and fatal involvements may increase by 155% by 2030. Drivers aged 65 and older will account for more than half of the total increase in fatal crashes and about 40% of the expected increase in all crash involvements; they are expected to account for as much as 25% of total driver fatalities in 2030, compared with 14% presently. CONCLUSIONS: By most measures, older drivers are at less risk of being involved in police reported crashes but at higher risk of being in fatal crashes. Although any projections of future crash counts have inherent uncertainty, there is strong evidence that older drivers will make up a substantially larger proportion of drivers involved in fatal crashes by 2030 because of future increases in the proportion of the population aged 65 and older, and trends toward increased licensure rates and higher annual mileage among older persons. Countermeasures to reduce the anticipated death toll among older drivers should address the increased susceptibility to injury of older vehicle occupants in crashes.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Acidentes de Trânsito/mortalidade , Acidentes de Trânsito/tendências , Fatores Etários , Idoso , Feminino , Humanos , Masculino , Estados Unidos/epidemiologia
14.
Med Sci Sports Exerc ; 33(11): 1803-10, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11689728

RESUMO

PURPOSE: Previous studies among young pitchers have focused on the frequency and description of elbow injuries. The purpose of this study was to evaluate the frequency of elbow and shoulder complaints in young pitchers and to identify the associations between pitch types, pitch volume, and other risk factors for these conditions. METHODS: A prospective cohort study of 298 youth pitchers was conducted over two seasons. Each participant was contacted via telephone after each game pitched to identify arm complaints. Generalized estimating equations were used to assess associations between arm complaints and independent variables. RESULTS: The frequency of elbow pain was 26%; that of shoulder pain, 32%. Risk factors for elbow pain were increased age, increased weight, decreased height, lifting weights during the season, playing baseball outside the league, decreased self-satisfaction, arm fatigue during the game pitched, and throwing fewer than 300 or more than 600 pitches during the season. Risk factors for shoulder pain included decreased satisfaction, arm fatigue during the game pitched, throwing more than 75 pitches in a game, and throwing fewer than 300 pitches during the season. CONCLUSION: Arm complaints are common, with nearly half of the subjects reporting pain. The factors associated with elbow and shoulder pain were different, suggesting differing etiologies. Developmental factors may be important in both. To lower the risk of pain at both locations, young pitchers probably should not throw more than 75 pitches in a game. Other recommendations are to remove pitchers from a game if they demonstrate arm fatigue and limit pitching in nonleague games.


Assuntos
Artralgia/epidemiologia , Traumatismos em Atletas/epidemiologia , Beisebol/lesões , Lesões no Cotovelo , Dor de Ombro/epidemiologia , Alabama/epidemiologia , Traumatismos do Braço/epidemiologia , Beisebol/fisiologia , Fenômenos Biomecânicos , Criança , Lateralidade Funcional , Humanos , Estudos Longitudinais , Educação Física e Treinamento/métodos , Fatores de Risco , Análise e Desempenho de Tarefas , Fatores de Tempo
15.
Leukemia ; 15(8): 1286-92, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11480573

RESUMO

Thymic stromal lymphopoietin (TSLP) is a novel cytokine that was found to promote the development of murine B cells in vitro. Here we describe the cloning and characterization of the human homologue of murine TSLP. This protein, which is expressed in a number of tissues including heart, liver and prostate, prevented apoptosis and stimulated growth of the human acute myeloid leukemia (AML)-derived cell line MUTZ-3. Anti-interleukin (IL)-7 receptor antibodies (Abs) neutralized this effect indicating that TSLP binds to at least part of the IL-7 receptor complex. TSLP induced phosphorylation of signal transducer and activator of transcription (STAT)-5. In contrast to IL-7, TSLP-triggered STAT-5 phosphorylation was not preceded by activation of janus kinase (JAK) 3. These findings would be in accordance with the notion, raised previously for the mouse system, that TSLP leads to STAT-5 phosphorylation by activating other kinases than the JAKs. Some other signaling pathways stimulated by many cytokines are not involved in TSLP activity; thus, TSLP did not stimulate activation of ERK1,2 and p70S6K. Furthermore, neutralizing Abs raised against cytokines known to stimulate the growth of MUTZ-3 cells did not inhibit the proliferative effects of TSLP, suggesting that TSLP-induced growth was a direct effect. In summary, we describe the cloning of human TSLP and its proliferative effects on a myeloid cell line. TSLP-induced proliferation is preceded by phosphorylation of STAT-5, but not of JAK 3.


Assuntos
Citocinas/genética , Proteínas do Leite , Sequência de Aminoácidos , Sequência de Bases , Clonagem Molecular , Citocinas/análise , Citocinas/farmacologia , Proteínas de Ligação a DNA/genética , Proteínas de Ligação a DNA/metabolismo , Humanos , Dados de Sequência Molecular , Fosforilação , Proteínas Tirosina Quinases/genética , Proteínas Tirosina Quinases/metabolismo , Fator de Transcrição STAT5 , Transdução de Sinais/efeitos dos fármacos , Transdução de Sinais/genética , Transativadores/genética , Transativadores/metabolismo , Linfopoietina do Estroma do Timo
16.
J Cell Biol ; 154(1): 17-20, 2001 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-11448985

RESUMO

In vivo studies on the dynamics of the nuclear pore complex (NPC) in yeast suggested that NPCs are highly mobile in the nuclear envelope. However, new evidence indicates that in mammalian cells NPCs are stably attached to a flexible lamina framework, but a peripheral component can exchange rapidly with an intranuclear pool.


Assuntos
Núcleo Celular/metabolismo , Membrana Nuclear/metabolismo , Complexo de Proteínas Formadoras de Poros Nucleares , Poro Nuclear/metabolismo , Transporte Ativo do Núcleo Celular , Animais , Membrana Basal/química , Modelos Biológicos , Proteínas Nucleares/química
18.
Br J Haematol ; 109(1): 211-20, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10848802

RESUMO

Aplastic anaemia (AA) is an immune-mediated bone marrow failure associated with high serum levels of flt3 ligand (FL). We examined expression of the membrane-bound isoform of FL in peripheral blood and bone marrow cells from AA patients at diagnosis (n = 16) and after immunosuppressive (IS) treatment (n = 36). Flow cytometry demonstrated strongly increased FL levels on the cell surface of T lymphocytes in AA relative to normal controls (P < 0.0001). T-cell-specific expression of membrane-bound FL was confirmed by confocal microscopy. FL mRNA and total cellular FL protein levels were increased about threefold. Overexpression of FL in AA was observed for up to 20 years after IS treatment. FL levels correlated inversely with CD34+ cell numbers and the colony-forming ability of AA bone marrow (R = -0.68 and -0.85 respectively). Histological examination of spleen specimens and bone marrow biopsies gave no evidence of degeneration or fibrosis due to prolonged exposure to high FL. Levels of membrane-bound FL were not increased in autoimmune diseases (n = 23), including rheumatoid arthritis and lupus erythematosus, nor in graft-versus-host disease (n = 8). Chronic overexpression of FL on the surface of T lymphocytes in AA, but not in other T-cell-mediated disorders, suggests that membrane-bound FL plays a role in cell-cell interactions in bone marrow failure and may be important for long-term haemopoietic recovery.


Assuntos
Anemia Aplástica/metabolismo , Proteínas de Membrana/metabolismo , Linfócitos T/metabolismo , Adolescente , Adulto , Idoso , Anemia Aplástica/patologia , Anemia Aplástica/terapia , Western Blotting , Medula Óssea/patologia , Estudos de Casos e Controles , Criança , Ensaio de Unidades Formadoras de Colônias , Feminino , Fibrose , Citometria de Fluxo/métodos , Humanos , Imunossupressores/uso terapêutico , Masculino , Proteínas de Membrana/análise , Proteínas de Membrana/uso terapêutico , Microscopia Confocal , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Baço/patologia , Estatísticas não Paramétricas
19.
Blood ; 95(11): 3489-97, 2000 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-10828034

RESUMO

The ligand for the receptor tyrosine kinase fms-like tyrosine kinase 3 (flt3), also referred to as fetal liver kinase-2 (flk-2), has an important role in hematopoiesis. The flt3 ligand (flt3L) is a growth factor for hematopoietic progenitors and induces hematopoietic progenitor and stem cell mobilization in vivo. In addition, when mice are treated with flt3L immature B cells, natural killer (NK) cells and dendritic cells (DC) are expanded in vivo. To further elucidate the role of flt3L in hematopoiesis, mice lacking flt3L (flt3L-/-) were generated by targeted gene disruption. Leukocyte cellularity was reduced in the bone marrow, peripheral blood, lymph nodes (LN), and spleen. Thymic cellularity, blood hematocrit, and platelet numbers were not affected. Significantly reduced numbers of myeloid and B-lymphoid progenitors were noted in the BM of flt3L-/- mice. In addition a marked deficiency of NK cells in the spleen was noted. DC numbers were also reduced in the spleen, LN, and thymus. Both myeloid-related (CD11c(++) CD8alpha(-)) and lymphoid-related (CD11c(++) CD8alpha(+)) DC numbers were affected. We conclude that flt3L has an important role in the expansion of early hematopoietic progenitors and in the generation of mature peripheral leukocytes.


Assuntos
Linfócitos B/citologia , Células Dendríticas/citologia , Hematopoese/fisiologia , Células-Tronco Hematopoéticas/imunologia , Células Matadoras Naturais/citologia , Proteínas de Membrana/fisiologia , Animais , Linfócitos B/efeitos dos fármacos , Linfócitos B/imunologia , Medula Óssea/imunologia , Ensaio de Unidades Formadoras de Colônias , Células Dendríticas/efeitos dos fármacos , Células Dendríticas/imunologia , Biblioteca Genômica , Hematopoese/genética , Células-Tronco Hematopoéticas/citologia , Células-Tronco Hematopoéticas/efeitos dos fármacos , Humanos , Interleucina-7/farmacologia , Células Matadoras Naturais/efeitos dos fármacos , Células Matadoras Naturais/imunologia , Cinética , Leucócitos/citologia , Ligantes , Linfonodos/imunologia , Teste de Cultura Mista de Linfócitos , Proteínas de Membrana/deficiência , Proteínas de Membrana/genética , Proteínas de Membrana/farmacologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Poli I-C/farmacologia , Proteínas Recombinantes/farmacologia , Baço/imunologia , Timo/imunologia
20.
J Biol Chem ; 275(9): 6680-8, 2000 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-10692478

RESUMO

To further identify amino acid domains involved in the ligand binding specificity of alpha(IIb)beta(3), chimeras of the conserved calcium binding domains of alpha(IIb) and the alpha subunit of the fibronectin receptor alpha(5)beta(1) were constructed. Chimeras that replaced all four calcium binding domains, replaced all but the second calcium binding domain of alpha(IIb) with those of alpha(5), or deleted all four calcium binding domains were synthesized but not expressed on the cell surface. Additional chimeras exchanged subsets or all of the variant amino acids in the second calcium binding domain, a region implicated in ligand binding. Cell surface expression of each second calcium binding domain mutant complexed with beta(3) was observed. Each second calcium binding domain mutant was able to 1) bind to immobilized fibrinogen, 2) form fibrinogen-dependent aggregates after treatment with dithiothreitol, and 3) bind the activation-dependent antibody PAC1 after LIBS 6 treatment. Soluble fibrinogen binding studies suggested that there were only small changes in either the K(d) or B(max) of any mutant. We conclude that chimeras of alpha(IIb) containing the second calcium binding domain sequences of alpha(5) are capable of complexing with beta(3), that the complexes are expressed on the cell surface, and that mutant complexes are capable of binding both immobilized and soluble fibrinogen, suggesting that the second calcium binding domain does not determine ligand binding specificity.


Assuntos
Cálcio/metabolismo , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/genética , Receptores de Fibronectina/genética , Proteínas Recombinantes de Fusão/genética , Sequência de Aminoácidos , Animais , Anticorpos Monoclonais/metabolismo , Sítios de Ligação/genética , Células COS , Agregação Celular , Dimerização , Fibrinogênio/metabolismo , Citometria de Fluxo , Dados de Sequência Molecular , Mutação , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Ligação Proteica/genética , Receptores de Fibronectina/metabolismo , Proteínas Recombinantes de Fusão/metabolismo , Transfecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...