1.
Med Phys ; 51(5): 3590-3596, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38128027

RESUMO

BACKGROUND: Protocol standardization and optimization for clinical translation of emerging quantitative multiparametric (mp)MRI biomarkers of high-risk prostate cancer requires imaging references that mimic realistic tissue value combinations for bias assessment in derived relaxation and diffusion parameters. PURPOSE: This work aimed to develop a novel class of hydrogel-based synthetic materials with simultaneously controlled quantitative relaxation, diffusion, and kurtosis parameters that mimic in vivo prostate value combinations in the same spatial compartment and allow stable assemblies of adjacent structures. METHODS: A set of materials with tunable T2, diffusion, and kurtosis were assembled to create quantitative biomimetic (mp)MRI references. T2 was controlled with variable agarose concentration, monoexponential diffusion by polyvinylpyrrolidone (PVP), and kurtosis by addition of lamellar vesicles. The materials were mechanically stabilized by UV cross-linked polyacrylamide gels (PAG) to allow biomimetic morphologies. The reference T2 were measured on a 3T scanner using multi-echo CPMG, and diffusion kurtosis-with multi-b DWI. RESULTS: Agarose concentration controls T2 values which are nominally independent of PVP or vesicle concentration. For agarose PVP hydrogels, monoexponential diffusion values are a function of PVP concentration and independent of agarose concentration. Compared to free vesicles, for agarose-PAG combined with vesicles, diffusion was predominantly controlled by vesicles and PAG, while kurtosis was affected by agarose and vesicle concentration. Both hydrogel classes achieved image voxel parameter values (T2, Da, Ka) for relaxation (T2: 65-255 ms), apparent diffusion (Da: 0.8-1.7 µm2/ms), and kurtosis (Ka: 0.5-1.25) within the target literature ranges for normal prostate zones and cancer lesions. Relaxation and diffusion parameters remained stable for over 6 months for layered material assemblies. CONCLUSION: A stable biomimetic mpMR reference based on hydrogels has been developed with a range of multi-compartment diffusion and relaxation parameter combinations observed in cancerous and healthy prostate tissue.


Assuntos
Hidrogéis , Neoplasias da Próstata , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Hidrogéis/química , Humanos , Difusão , Imageamento por Ressonância Magnética Multiparamétrica , Materiais Biomiméticos/química , Imageamento por Ressonância Magnética
2.
Ultrasound Med Biol ; 49(4): 1018-1030, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36690519

RESUMO

OBJECTIVE: Liver fibrosis has been found to increase the mechanical stiffness of the liver. To mimic different stages of liver fibrosis, commercially available phantoms (Model 039, CIRS, Inc.) have been produced for clinical quality assurance and research purposes. The purpose of this study was to investigate the mechanical property variability of the phantoms in two lots of CIRS Model 039 phantoms. METHODS: Each lot consisted of phantoms of four stiffness types, and there were 8-10 phantoms of each type. Shear wave elastography measurements were conducted on each phantom at 10 different angles. Group velocity measurements and phase velocity curves were calculated for every SWE acquisition. Multilevel functional principal component analysis (MFPCA) was performed on phase velocity data, which decomposes each phase velocity curve into the sum of eigenfunctions of two levels. The variance of the component scores of levels 1 and 2 were used to represent inter-phantom and intra-phantom variability, respectively. The 95% confidence intervals of phase velocity in a phantom type were calculated to reflect curve variability. DISCUSSION: The standard deviations of the group velocity for phantoms of any type were less than 0.04 and 0.02 m/s for lots 1 and 2, respectively. For both lots, in every type, the phase velocity curves of most individual phantoms fall within the 95% confidence interval. CONCLUSION: MFPCA is an effective tool for analyzing the inter- and intra-phantom variability of phase velocity curves. Given the known variability of a fully tested lot, estimation of the variability of a new lot can be performed with a reduced number of phantoms tested.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Cirrose Hepática , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Proteínas de Ciclo Celular
3.
Radiother Oncol ; 159: 224-230, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33798611

RESUMO

PURPOSE: The purpose of this phantom study is to demonstrate that thermoacoustic range verification could be performed clinically. Thermoacoustic emissions generated in an anatomical multimodality imaging phantom during delivery of a clinical plan are compared to simulated emissions to estimate range shifts compared to the treatment plan. METHODS: A single-field 12-layerproton pencil beam scanning (PBS)treatment plancreated in Pinnacle prescribing6 Gy/fractionwas delivered by a superconducting synchrocyclotron to a triple modality (CT, MRI, and US) abdominal imaging phantom.Data was acquired by four acoustic receivers rigidly affixed to a linear ultrasound array. Receivers 1-2 were located distal to the treatment volume, whereas 3-4 were lateral. Receivers' room coordinates were computed relative to the ultrasound image plane after co-registration to the planning CT volume. For each prescribed beamlet, a set of thermoacoustic emissions corresponding to varied beam energies were computed. Simulated emissions were compared to measured emissions to estimate shifts of the Bragg peak. RESULTS: Shifts were small for high-dose beamlets that stopped in soft tissue. Signals acquired by channels 1-2 yielded shifts of -0.2±0.7mm relative to Monte Carlo simulations for high dose spots (~40 cGy) in the second layer. Additionally, for beam energy ≥125 MeV, thermoacoustic emissions qualitatively tracked lateral motion of pristine beams in a layered gelatin phantom, and time shifts induced by changing phantom layers were self-consistent within nanoseconds. CONCLUSIONS: Acoustic receivers tuned to spectra of thermoacoustic emissions may enable range verification during proton therapy.


Assuntos
Terapia com Prótons , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Ultrassonografia
4.
J Ultrasound Med ; 40(3): 569-581, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33410183

RESUMO

OBJECTIVES: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz. RESULTS: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a - 0.27 ± 0.027-m/s (-12.2% ± 1.2%) bias when using the clinically implemented 60-Hz vibration source. CONCLUSIONS: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140-Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.


Assuntos
Técnicas de Imagem por Elasticidade , Biomarcadores , Elasticidade , Humanos , América do Norte , Imagens de Fantasmas
5.
Phys Med Biol ; 59(19): 5775-93, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25208061

RESUMO

Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young's modulus over the range of normal and cirrhotic liver stiffnesses. The Young's modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.


Assuntos
Biomimética , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Imagens de Fantasmas , Humanos , Padrões de Referência , Resistência ao Cisalhamento , Ultrassonografia
6.
Physiol Meas ; 32(8): 1301-13, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21765205

RESUMO

Ultrasound has been widely used to nondestructively evaluate various materials, including biological tissues. Quantitative ultrasound has been used to assess bone quality and fracture risk. A pulsed phase-locked loop (PPLL) method has been proven for very sensitive tracking of ultrasound time-of-flight (TOF) changes. The objective of this work was to determine if the PPLL TOF tracking is sensitive to bone deformation changes during loading. The ability to noninvasively detect bone deformations has many implications, including assessment of bone strength and more accurate osteoporosis diagnostics and fracture risk prediction using a measure of bone mechanical quality. Fresh sheep femur cortical bone shell samples were instrumented with three 3-element rosette strain gauges and then tested under mechanical compression with eight loading levels using an MTS machine. Samples were divided into two groups based on internal marrow cavity content: with original marrow, or replaced with water. During compressive loading ultrasound waves were measured through acoustic transmission across the mid-diaphysis of bone. Finite element analysis (FEA) was used to describe ultrasound propagation path length changes under loading based on µCT-determined bone geometry. The results indicated that PPLL output correlates well to measured axial strain, with R(2) values of 0.70 ± 0.27 and 0.62 ± 0.29 for the marrow and water groups, respectively. The PPLL output correlates better with the ultrasound path length changes extracted from FEA. For the two validated FEA tests, correlation was improved to R(2) = 0.993 and R(2) = 0.879 through cortical path, from 0.815 and 0.794 via marrow path, respectively. This study shows that PPLL readings are sensitive to displacement changes during external bone loading, which may have potential to noninvasively assess bone strain and tissue mechanical properties.


Assuntos
Fêmur/fisiologia , Análise de Elementos Finitos , Fisiologia/métodos , Estresse Mecânico , Animais , Fenômenos Biomecânicos/fisiologia , Fêmur/diagnóstico por imagem , Reprodutibilidade dos Testes , Ovinos , Ultrassonografia , Microtomografia por Raio-X