Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev. calid. asist ; 26(1): 54-61, ene.-feb. 2011. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-86055

RESUMO

Objetivo. Determinar la validez y la fiabilidad del índice de personalización de cuidados (IPC). Método. Estudio transversal realizado en el Hospital Puerta del Mar (Cádiz) del Servicio Andaluz de Salud, que incluyó a todos los pacientes ingresados en la unidad de Medicina Interna, 1.a sección, desde mayo 2007 a julio 2008. Se hizo un análisis descriptivo de la población estudiada y se calculó la fiabilidad, mediante el coeficiente 20 de Kuder-Richardson y una matriz de correlación de los ítems del IPC, y la validez, con un análisis factorial de máxima verosimilitud y una curva ROC para determinar la sensibilidad y la especificidad. Resultados. Se incluyó a 219 sujetos; el 74,4% de los encuestados eran pacientes y el 25,6%, cuidadores familiares. El 50,7% son mujeres, con una media de edad de 62,5 años y el 48,4% tiene nivel de estudios básico. Se obtuvo un valor de coeficiente 20 de Kuder-Richardson para el IPC de 0,835 y una correlación de ítems positiva, que se corresponden con tres grupos de ítems (factores). El análisis factorial de máxima verosimilitud confirmó los tres grupos mediante una rotación promax por la alta correlación entre ellos, y con una variancia máxima explicada del 91,42%. El área bajo la curva ROC es del 90,1%, con un punto de corte situado en 8 para una sensibilidad del 79,9% y una especificidad del 90,6%. Conclusiones. La fiabilidad del IPC, medida con la consistencia interna, está dentro del rango óptimo. Además, los factores de la matriz de correlaciones entre ítems se confirman mediante el análisis factorial, obteniendo una elevadísima variancia total explicada. El área bajo la curva ROC obtiene un excelente resultado frente al patrón de referencia considerado, la percepción de la relación de confianza(AU)


Objectives. To determine the validity and reliability of the personalised nursing care index (PNCI). Methods. A descriptive study was carried out in the Puerta del Mar Hospital (Cádiz) of the Andalusian Health Service, which included all patients admitted to an Internal Medicine ward from May 2007 to July 2008. A descriptive analysis was performed on the population included in the study. Furthermore, reliability was analysed with the 20-Kuder-Richardson coefficient and a correlation matrix between PNCI items; and validity via a maximum likelihood factorial analysis, and a ROC curve to determine sensitivity and specificity. Results. A total of 219 people were included in the survey, of whom 74.4% were patients and 26.6% caregivers. The percentages of males and females were similar with a mean age of 62.5 years and 48.4% finished basic school education. The 20-Kuder-Richarson value was 0.835; and a positive correlation between items, which corresponded to 3 groups of items (factors). The maximum likelihood factorial analysis confirmed the 3 items-factor groups with a Promax rotation due to the high correlation between them. The maximum explained variance was 91.42%. The ROC curve area was 90.1% with a cut-off point of 8, for a sensitivity of 79.9% and a specificity of 90.6%. Conclusions. The PCNI is reliable, with the internal consistency coefficient value in between an optimum range. Furthermore, factors obtained from the matrix correlation inter-items were confirmed with a factorial analysis, resulting in a high explained variance. The curve ROC area is excellent compared to the gold standard, considered as the perception of confidence relationship(AU)


Assuntos
Humanos , Masculino , Feminino , Papel do Profissional de Enfermagem , Enfermagem Primária/métodos , Enfermagem Primária , Cuidados Pré-Operatórios/enfermagem , Sensibilidade e Especificidade , Inquéritos e Questionários , Estudos Transversais , Análise Fatorial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...