Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiol Prot ; 37(1): R1-R18, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-28118156

RESUMO

Proper understanding of the risk of radiation-induced late effects for patients receiving external photon beam radiotherapy requires the determination of reliable dose-response relationships. Although significant efforts have been devoted to improving dose estimates for the study of late effects, the most often questioned explanatory variable is still the dose. In this work, based on a literature review, we provide an in-depth description of the radiotherapy dose reconstruction process for the study of late effects. In particular, we focus on the identification of the main sources of dose uncertainty involved in this process and summarise their impacts on the dose-response relationship for radiotherapy late effects. We provide a number of recommendations for making progress in estimating the uncertainties in current studies of radiotherapy late effects and reducing these uncertainties in future studies.


Assuntos
Relação Dose-Resposta à Radiação , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Humanos , Medição de Risco , Incerteza
2.
J Appl Clin Med Phys ; 17(1): 143-157, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894346

RESUMO

The purpose of this investigation was to evaluate the dose on megavoltage CT (MVCT) images required for tomotherapy. As imaging possibilities are often used before each treatment and usually used several times before the session, we tried to evaluate the dose delivered during the procedure. For each scanning mode (fine, normal, and coarse), we first established the relative variation of these doses according to different technical parameters (explored length, patient setup). These dose variations measured with the TomoPhant, also known as Cheese phantom, showed the expected variations (due to the variation of scattered radiation) of 15% according to the explored length and ± 5% according to the phantom setup (due to the variation of the point of measurement in the bore). In order to estimate patient doses, an anthropomorphic phantom was used for thermoluminescent and film dosimetry. The degree of agreement between the two methods was very satisfactory (the differences correspond to 5 mGy per imaging session) for the three sites studied (head & neck, thorax, and abdomen). These measurements allowed us to estimate the delivered dose of between 1 cGy and 4 cGy according to the site and imaging mode. Finally, we attempted to investigate a way to calculate this delivered dose in our patients from the study conducted on a cylindrical phantom and by taking into account data from the initial kV-CT scan. The results we obtained were close to our measurements, with discrepancies below 5 mGy per MVCT.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Dosimetria Fotográfica/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagens de Fantasmas , Radioterapia Guiada por Imagem/métodos , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias Abdominais/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Processamento de Imagem Assistida por Computador , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Neoplasias Torácicas/radioterapia
3.
J Appl Clin Med Phys ; 16(6): 435­448, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699572

RESUMO

The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.


Assuntos
Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Elétrons/uso terapêutico , Desenho de Equipamento , Dosimetria Fotográfica , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/estatística & dados numéricos , Dosimetria Termoluminescente , Água
4.
Int J Radiat Oncol Biol Phys ; 90(5): 1216-24, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25442047

RESUMO

PURPOSE: To present a method for calculating dose-volume histograms (DVH's) to the active bone marrow (ABM) of patients who had undergone radiation therapy (RT) and subsequently developed leukemia. METHODS AND MATERIALS: The study focuses on 15 patients treated between 1961 and 1996. Whole-body RT planning computed tomographic (CT) data were not available. We therefore generated representative whole-body CTs similar to patient anatomy. In addition, we developed a method enabling us to obtain information on the density distribution of ABM all over the skeleton. Dose could then be calculated in a series of points distributed all over the skeleton in such a way that their local density reflected age-specific data for ABM distribution. Dose to particular regions and dose-volume histograms of the entire ABM were estimated for all patients. RESULTS: Depending on patient age, the total number of dose calculation points generated ranged from 1,190,970 to 4,108,524. The average dose to ABM ranged from 0.3 to 16.4 Gy. Dose-volume histograms analysis showed that the median doses (D50%) ranged from 0.06 to 12.8 Gy. We also evaluated the inhomogeneity of individual patient ABM dose distribution according to clinical situation. It was evident that the coefficient of variation of the dose for the whole ABM ranged from 1.0 to 5.7, which means that the standard deviation could be more than 5 times higher than the mean. CONCLUSIONS: For patients with available long-term follow-up data, our method provides reconstruction of dose-volume data comparable to detailed dose calculations, which have become standard in modern CT-based 3-dimensional RT planning. Our strategy of using dose-volume histograms offers new perspectives to retrospective epidemiological studies.


Assuntos
Medula Óssea/anatomia & histologia , Medula Óssea/efeitos da radiação , Leucemia Induzida por Radiação , Doses de Radiação , Adolescente , Adulto , Fatores Etários , Osso e Ossos/anatomia & histologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Análise por Pareamento , Ilustração Médica , Pessoa de Meia-Idade , Neoplasias/radioterapia , Estudos Retrospectivos , Fatores de Tempo
5.
Eur J Immunol ; 43(9): 2263-72, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23765389

RESUMO

Treg cells hold enormous promise for therapeutic application in GVH disease, a lethal complication of allogeneic HSC transplantation. Mouse studies showed that donor-derived recipient-specific Treg (rsTreg) cells are far more efficient than polyclonal Treg cells in suppressing GVH disease. However, clinical grade preparations of rsTreg cells carries the risk of containing significant numbers of highly pathogenic recipient-specific effector T cells. We hypothesized that an alternative approach using Treg cells specific for an exogenous (i.e. nondonor, nonrecipient) Ag (exoTreg cells) can overcome this risk by taking advantage of the bystander suppressive effect of Treg cells. For this, we used a murine model for aggressive GVH disease. We expanded ex vivo exoTreg cells that are primed against the HY Ag, which is only expressed in males. ExoTreg cells supressed GVH disease as efficiently as rsTreg cells in recipient male mice. We also applied this strategy in female mice that do not express this Ag. While exoTreg cells were not effective in female recipients when applied alone, providing the cognate HY Ag in vivo along side effectively activated exoTreg cells and completely abrogated GVH disease, establishing a targeted on/off system to provide a suppressive effect on alloreactive effector T cells.


Assuntos
Doença Enxerto-Hospedeiro/imunologia , Antígeno H-Y/imunologia , Linfócitos T Reguladores/imunologia , Linfócitos T Reguladores/transplante , Animais , Feminino , Ativação Linfocitária , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C3H , Camundongos Endogâmicos C57BL , Transplante Homólogo
6.
Clin Adv Hematol Oncol ; 11(2): 76-83, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23598908

RESUMO

The standard treatment for breast cancer patients at low risk of recurrence is based on conservative surgery followed by radiation therapy delivered to the whole breast. The accelerated partial breast irradiation (APBI) concept, developed more than 15 years ago, could be an option in selected patients. However, the ideal patient profile for APBI is still not clearly identified. Recent reports from the American Society for Radiation Oncology (ASTRO) and the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) have suggested selection criteria for "suitable patients" who could receive APBI outside of clinical trials. Currently, there are 6 ongoing phase III trials. All are characterized by a significant heterogeneity regarding inclusion criteria and stratification factors. The French UNICANCER trial (SHARE; ClinicalTrials.gov identifier NCT01247233) will randomize 2,800 patients in 3 arms: APBI (1 week) using 3-dimensional (3D) conformal radiotherapy, standard radiotherapy (6.5 weeks), and hypofractionated radiotherapy (3 weeks). In this article, we review the reported retrospective studies as well as older randomized trials. We will also describe the differences between the 6 ongoing phase III trials and the particularities of the French SHARE trial.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Mastectomia Segmentar , Radioterapia Conformacional/métodos , Neoplasias da Mama/cirurgia , Feminino , França , Humanos , Recidiva Local de Neoplasia/prevenção & controle , Seleção de Pacientes , Dosagem Radioterapêutica , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...