Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Echocardiography ; 37(8): 1205-1212, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32686870

RESUMO

INTRODUCTION: Chagas disease (ChD) is one of the main parasitic diseases in Latin-America. Its heart involvement is the most important cause of death. The aim of this study is to evaluate if Doppler Tissue Imaging (DTI) may have a predictive value for later events in subjects with chronic ChD. METHODS: we analyses DTI variables of 543 patients with chronic ChD for the evaluation of predicting factors of events. Major adverse cardiovascular events (MACE) were considered as stroke, heart failure resistant to treatment, sustained ventricular tachycardia, implantable cardioverter-defibrillator, sudden death, and cardiovascular death. The following findings were also included in total evens: heart failure, bradycardia, ventricular arrhythmia, new conduction system abnormalities, and new echocardiographic abnormalities. Multivariate analysis with logistic regression was used in order to assess the Doppler and DTI parameters predicting events. Variables with a P-value ≤ .5 in the univariate analysis were included in the multivariate analysis. RESULTS: In patients with chronic ChD, the analysis of DTI parameters showed that S' wave and E' wave of the lateral wall of the left ventricle were significant predictors of MACE (OR: 0.83; 95% CI: 0.71-0.96; P-value: .015 and OR: 0.80; 95% CI: 0.66-0.98; P-value: .031, respectively). CONCLUSIONS: This study found that patients with chronic ChD who had events showed significantly lower parameters in the DTI. What is more, this study showed that even lower DTI parameters are significant predictors of events.


Assuntos
Doença de Chagas , Insuficiência Cardíaca , Doença de Chagas/complicações , Doença de Chagas/diagnóstico por imagem , Ecocardiografia , Ventrículos do Coração , Humanos , Ultrassonografia Doppler
2.
Echocardiography ; 37(2): 293-301, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31957094

RESUMO

BACKGROUND: Fabry disease (FD) is a rare X-linked storage disorder caused by deficiency of the lysosomal enzyme α-galactosidase A, and it typically causes multiorgan dysfunction. The main cause of death is heart disease resulting from left ventricular (LV) diastolic dysfunction, LV systolic dysfunction, severe LV hypertrophy (LVH), and sudden death. In several cardiac disorders, LV systolic dysfunction and ventricular arrhythmias are associated with mechanical dispersion (MD). MD has until now not been studied in patients with FD. OBJECTIVE: To investigate the prevalence of MD in patients with FD. METHODS: Complete echocardiographic data and speckle tracking echocardiographic data were collected. MD is an index of inter-segmental discoordination of contraction and is defined as the standard deviation (SD) of the time-to-peak longitudinal negative strain in 17 LV segments with a value >49 milliseconds. Patients with FD were divided into the following 2 groups: group I (patients with FD but no LVH, n = 64) and group II (patients with FD and LVH, n = 25). These groups were compared with a group of healthy subjects (group III, n = 50). Parametric variables were expressed as mean ± SD, and nonparametric variables were expressed as median and inter-quartile range. A P value <.05 was considered significant. RESULTS: A total of 113 patients with FD were included in this study. Of these, 24 (21%) were excluded because of poor imaging quality or presence of comorbidities, and the final study population consisted of 89 patients (mean age of 33.5 ± 14.5 years, 64% female). Group II patients were older than group I patients (46 ± 13 years vs 27 ± 11 years, P < .0001). There was no difference in LV ejection fraction between the 3 groups. There was also no difference in MD between groups I and III (32.4 ms [26-39] vs 32 ms [26-39]). In group II, the MD in 19 patients (76%) was 56 ms (39-80). CONCLUSIONS: To the best of our knowledge, this is the first study to assess the prevalence of MD in patients with FD. MD was observed in 76% of patients with FD and LVH. The use of MD in strain echocardiography may be beneficial in the assessment of patients with FD who develop heart failure.


Assuntos
Doença de Fabry , Disfunção Ventricular Esquerda , Adulto , Ecocardiografia , Doença de Fabry/complicações , Doença de Fabry/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adulto Jovem
3.
J Echocardiogr ; 12(1): 40-2, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27278915

RESUMO

We report the case of a rare congenital anomaly, a double-orifice mitral valve, in a 21-year-old woman who was asymptomatic and had no history of heart disease. Transthoracic echocardiography revealed two functionally normal orifices mitral valve of equal size. As the presentation in adulthood is rare, echocardiographers should be trained to make the appropriate diagnosis.

4.
Rev. argent. cardiol ; 81(6): 480-485, dic. 2013. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: lil-734457

RESUMO

El miocardio no compacto es una miocardiopatía genética primaria ocasionada por la detención de la embriogénesis normal del endocardio y el miocardio. Esta anomalía se asocia frecuentemente con arritmias, insuficiencia cardíaca y eventos embólicos. El presente estudio se llevó a cabo con el objetivo de describir la modalidad de presentación clínica y las características electrocardiográficas y ecocardiográficas en portadores de esta miocardiopatía. Se analizaron 22 pacientes con diagnóstico de miocardio no compacto detectados en el laboratorio de ecocardiografía entre julio de 2004 y abril de 2009. Toda la población en estudio fue analizada mediante electrocardiograma y eco-Doppler cardíaco transtorácico y en 12 casos se registró Holter de 24 horas. Se determinaron el peso, la altura y el índice de masa corporal, que se compararon contra 66 pacientes distribuidos en tres grupos de 22 pacientes cada uno: 1) grupo control de personas sin cardiopatías, 2) portadores de miocardiopatía hipertrófica y 3) pacientes con miocardiopatía dilatada idiopática. En la población estudiada con miocardio no compacto predominó el sexo femenino y se observó menor peso e índice de masa corporal en relación con los grupos comparados y el síntoma preponderante fue la disnea. El electrocardiograma mostró ritmo sinusal con trastornos de conducción y arritmia ventricular repetitiva. El eco transtorácico mostró diferentes grados de disfunción ventricular izquierda sistólica y diastólica con áreas de miocardio no compacto predominantes en los territorios medial y apical de los segmentos inferior, posterior y lateral, en algunos casos complicados con trombos intraventriculares y ocasionalmente asociados con fístulas coronarias.


Left ventricular noncompaction is a primary genetic cardiom-yopathy caused by arrest of normal embryogenesis of the endocardium and myocardium. This anomaly is frequently associated with arrhythmias, heart failure and thromboem-bolic events. The goal of the present study was to describe the clinical presentation and the electrocardiographic and echocardiographic characteristics of patients with this cardiomyopathy. Twenty-two patients with left ventricular noncompaction detected by echocardiography between July 2004 and April 2009 were analyzed. Electrocar di ogram and transthoracic Doppler echocardiography was performed to all the patients, and 12 patients underwent 24-hour Holter monitoring. Weight, height and body mass index were calculated and compared with 66 patients distributed in three groups of 22 patients each: 1) control group without heart disease, 2) hypertrophic cardiomyopathy; and 3) idiopathic dilated cardiomyopathy. In the population with left ventricular noncompaction, fe-male gender prevailed, lower weight and body mass index was observed and dyspnea was the most common symptom. The electrocardiogram showed sinus rhythm, conduction distur-bances and repetitive ventricular arrhythmia. Transthoracic echocardiography showed different degrees of systolic and diastolic left ventricular dysfunction with areas of noncom-paction in the mid and apical inferior, posterior and lateral segments; intraventricular thrombi were occasionally seen and sometimes associated with coronary artery fistulas.

5.
Rev. argent. cardiol ; 81(6): 480-485, dic. 2013. ilus, graf, tab
Artigo em Espanhol | BINACIS | ID: bin-129773

RESUMO

El miocardio no compacto es una miocardiopatía genética primaria ocasionada por la detención de la embriogénesis normal del endocardio y el miocardio. Esta anomalía se asocia frecuentemente con arritmias, insuficiencia cardíaca y eventos embólicos. El presente estudio se llevó a cabo con el objetivo de describir la modalidad de presentación clínica y las características electrocardiográficas y ecocardiográficas en portadores de esta miocardiopatía. Se analizaron 22 pacientes con diagnóstico de miocardio no compacto detectados en el laboratorio de ecocardiografía entre julio de 2004 y abril de 2009. Toda la población en estudio fue analizada mediante electrocardiograma y eco-Doppler cardíaco transtorácico y en 12 casos se registró Holter de 24 horas. Se determinaron el peso, la altura y el índice de masa corporal, que se compararon contra 66 pacientes distribuidos en tres grupos de 22 pacientes cada uno: 1) grupo control de personas sin cardiopatías, 2) portadores de miocardiopatía hipertrófica y 3) pacientes con miocardiopatía dilatada idiopática. En la población estudiada con miocardio no compacto predominó el sexo femenino y se observó menor peso e índice de masa corporal en relación con los grupos comparados y el síntoma preponderante fue la disnea. El electrocardiograma mostró ritmo sinusal con trastornos de conducción y arritmia ventricular repetitiva. El eco transtorácico mostró diferentes grados de disfunción ventricular izquierda sistólica y diastólica con áreas de miocardio no compacto predominantes en los territorios medial y apical de los segmentos inferior, posterior y lateral, en algunos casos complicados con trombos intraventriculares y ocasionalmente asociados con fístulas coronarias.(AU)


Left ventricular noncompaction is a primary genetic cardiom-yopathy caused by arrest of normal embryogenesis of the endocardium and myocardium. This anomaly is frequently associated with arrhythmias, heart failure and thromboem-bolic events. The goal of the present study was to describe the clinical presentation and the electrocardiographic and echocardiographic characteristics of patients with this cardiomyopathy. Twenty-two patients with left ventricular noncompaction detected by echocardiography between July 2004 and April 2009 were analyzed. Electrocar di ogram and transthoracic Doppler echocardiography was performed to all the patients, and 12 patients underwent 24-hour Holter monitoring. Weight, height and body mass index were calculated and compared with 66 patients distributed in three groups of 22 patients each: 1) control group without heart disease, 2) hypertrophic cardiomyopathy; and 3) idiopathic dilated cardiomyopathy. In the population with left ventricular noncompaction, fe-male gender prevailed, lower weight and body mass index was observed and dyspnea was the most common symptom. The electrocardiogram showed sinus rhythm, conduction distur-bances and repetitive ventricular arrhythmia. Transthoracic echocardiography showed different degrees of systolic and diastolic left ventricular dysfunction with areas of noncom-paction in the mid and apical inferior, posterior and lateral segments; intraventricular thrombi were occasionally seen and sometimes associated with coronary artery fistulas.(AU)

6.
Int J Cardiovasc Imaging ; 25(4): 363-70, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19184521

RESUMO

Tissue Doppler imaging (TDI) is generally used for the assessment of ventricular function, and to a lesser extent, to evaluate the left atrial appendage (LAA). In the present study, we used TDI to analyze the contractile function of the right atrial appendage (RAA). The aim of this study was a comprehensive evaluation of RAA and LAA contractile function in patients with mitral stenosis and sinus rhythm. A total of 69 patients were assessed: group 1 (23 patients with severe MS, 38 +/- 11 years, 20 women), group 2 (23 patients with mild MS, 39 +/- 12 years, 19 women) and group 3 (23 healthy subjects, 42 +/- 14 years, 16 women). Multiplane transesophageal echo was performed in all patients. The RAA was visualized at 130 degrees and the LAA at 0 degrees . TDI sample volume was placed in the tip of both atrial appendages, with an ultrasound beam angle < 10 degrees . Flow velocities and myocardial velocities were measured. The presence of thrombus and/or spontaneous echo contrast (SEC) was assessed. TDI showed in normal subjects, myocardial contraction velocities in RAA similar to that of the LAA (21.8 +/- 4.2 vs. 20.1 +/- 4 cm/s, respectively, P = NS). In patients with MS, myocardial velocities in both atrial appendages were significantly lower than in normal subjects (RAA: 17.4 +/- 5.1 vs. 21.8 +/- 4.2 cm/s, respectively, P < 0.01, LAA: 9 +/- 5.1 vs. 20.1 +/- 4 cm/s, respectively, P < 0.001). Linear regression analysis showed a correlation between the impairment of systolic function of both appendages, pulmonary arterial pressure, valve area and transmitral gradient. Of the 46 patients with MS, patients with intense SEC had lower flow and myocardial velocities in the LAA than patients without SEC (16 +/- 5 vs. 50 +/- 3 cm/s, 6 +/- 2 vs. 10.6 +/- 5.6 cm/s, respectively, P < 0.001 and P < 0.001). In healthy subjects, myocardial contraction velocities in both appendages were similar. Patients with MS and sinus rhythm had contractile dysfunction of both appendages, shown by the decrease in myocardial velocities and related to the increase in atrial afterload. Both appendages exhibited a relation between contractile dysfunction and the presence of SEC, but dysfunction was less marked in the RAA, which might explain the lower prevalence of thrombi in the RAA.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Adulto , Análise de Variância , Velocidade do Fluxo Sanguíneo , Estudos Transversais , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Estudos Prospectivos
7.
Eur J Echocardiogr ; 9(1): 196-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18267923

RESUMO

Thrombosis in a native aortic valve is a rare complication which may lead to systemic embolization. A few cases of aortic thrombosis in previously abnormal valves have been described. In this report, we describe a 42-year-old male who suffered two acute ischaemic attacks, one in the upper right limb and another in the cerebral territory supplied by the left sylvian artery, from a thrombus that developed in a bicuspid and stenotic aortic valve. The diagnosis was made with transthoracic and transoesophageal echocardiography, and the patient subsequently underwent surgery. In cases of bicuspid aortic valves, we should think of thrombosis as a possible complication with its resulting risk of embolism, and assess such patients with transthoracic and transoesophageal echocardiography, thus enabling their early detection and treatment.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Embolia/etiologia , Trombose/diagnóstico por imagem , Adulto , Estenose da Valva Aórtica/complicações , Humanos , Masculino , Recidiva , Trombose/etiologia , Ultrassonografia
8.
Rev. argent. cardiol ; 66(5): 559-62, sept.-oct. 1998. ilus
Artigo em Espanhol | LILACS | ID: lil-239459

RESUMO

Se presenta un hombre de 70 años, con antecedentes de hipertensión arterial, que padece un accidente cerebrovascular isquémico al quinto día de la cirugía de un adenocarcinoma de colon. El ecocardiograma trastorácico fue normal, pero el transesofágico mostró un gran trombo móvil adherido a una placa ateromatosa (debris) en la aorta torácica ascendente. Se realizó tratamiento anticoagulante y, al octavo mes del mismo, el ecocardiograma transesofágico comprobó la disolución del trombo sin detectarse complicaciones. El caso destaca la importancia del ecocardiograma transesofágico para detectar la fuente embolígena aórtica, la eficacia de la terapéutica anticoagulante y la posibilidad de un síndrome paraneoplásico


Assuntos
Humanos , Masculino , Idoso , Transtornos Cerebrovasculares/tratamento farmacológico , Transtornos Cerebrovasculares/terapia , Neoplasias do Colo/complicações , Neoplasias do Colo/cirurgia , Ecocardiografia Transesofagiana , Trombose/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Aorta Torácica
9.
Rev. argent. cardiol ; 66(5): 559-62, sept.-oct. 1998. ilus
Artigo em Espanhol | BINACIS | ID: bin-15723

RESUMO

Se presenta un hombre de 70 años, con antecedentes de hipertensión arterial, que padece un accidente cerebrovascular isquémico al quinto día de la cirugía de un adenocarcinoma de colon. El ecocardiograma trastorácico fue normal, pero el transesofágico mostró un gran trombo móvil adherido a una placa ateromatosa (debris) en la aorta torácica ascendente. Se realizó tratamiento anticoagulante y, al octavo mes del mismo, el ecocardiograma transesofágico comprobó la disolución del trombo sin detectarse complicaciones. El caso destaca la importancia del ecocardiograma transesofágico para detectar la fuente embolígena aórtica, la eficacia de la terapéutica anticoagulante y la posibilidad de un síndrome paraneoplásico (AU)


Assuntos
Humanos , Masculino , Idoso , Neoplasias do Colo/cirurgia , Neoplasias do Colo/complicações , Ecocardiografia Transesofagiana , Trombose/tratamento farmacológico , Transtornos Cerebrovasculares/terapia , Transtornos Cerebrovasculares/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Aorta Torácica
10.
Rev. argent. cardiol ; 66(3): 279-86, mayo-jun. 1998. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-239434

RESUMO

Se evaluó la presencia de cortocircuitos interauriculares y la asociación de eventos isquémicos cerebrovasculares en 20 pacientes portadores de aneurisma del septum interauricular (ASIA), realizándose ecocardiograma y Doppler color transtorácico (ETT) y transesofágico (ETE), con contraste en condiciones basales y durante la maniobra de Valsalva. Tuvo cortocircuito interauricular el 70 por ciento (14/20). De éstos, el 71 por ciento fue identificado por ETT con contraste y Valsalva y el 50 por ciento por ETE color, ETT y ETE con contraste en condiciones basales. El 15 por ciento de los pacientes con ASIA mostró accidente cerebrovascular isquémico, transitorio o constituído, de origen indeterminado


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Aneurisma , Comunicação Interventricular , Transtornos Cerebrovasculares , Ecocardiografia Doppler , Ecocardiografia Transesofagiana
11.
Rev. argent. cardiol ; 66(3): 279-86, mayo-jun. 1998. ilus, tab
Artigo em Espanhol | BINACIS | ID: bin-15748

RESUMO

Se evaluó la presencia de cortocircuitos interauriculares y la asociación de eventos isquémicos cerebrovasculares en 20 pacientes portadores de aneurisma del septum interauricular (ASIA), realizándose ecocardiograma y Doppler color transtorácico (ETT) y transesofágico (ETE), con contraste en condiciones basales y durante la maniobra de Valsalva. Tuvo cortocircuito interauricular el 70 por ciento (14/20). De éstos, el 71 por ciento fue identificado por ETT con contraste y Valsalva y el 50 por ciento por ETE color, ETT y ETE con contraste en condiciones basales. El 15 por ciento de los pacientes con ASIA mostró accidente cerebrovascular isquémico, transitorio o constituído, de origen indeterminado (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Aneurisma , Comunicação Interventricular/diagnóstico por imagem , Transtornos Cerebrovasculares , Ecocardiografia Doppler , Ecocardiografia Transesofagiana
12.
Acta physiol. pharmacol. latinoam ; 38(1): 19-25, ene.-mar. 1988. ilus
Artigo em Espanhol | LILACS | ID: lil-96486

RESUMO

Se ha registrado, mediante sensores piezoelétricos, la variación del estado contráctil consecuente a la hipertensión pulmonar aguda severa, provocada en corazones normales de perros por la estenosis experimental de la arteria pulmonar. Durante el proceso de la estenosis se aprecia, por una parte, un incremento proporcional sólo de la tensión isométrica de la pared del ventrículo derecho y del "kick" auricular, debidos a la dificultad creciente en la evacuación del contenido sanguíneo de ambas cavidades, y por otra parte, la pérdida de la distensibilidad de la pared, que al tornarse más rígida, limita el desarrollo de las presiones sistólica y diastólica del ventículo derecho. En tanto, el sensor isquierdo, describe las variaciones consecuentes a la contracción de dicha pared ventricular


Assuntos
Cães , Animais , Masculino , Feminino , Hipertensão Pulmonar/fisiopatologia , Contração Miocárdica , Estenose da Valva Pulmonar/fisiopatologia , Doença Aguda
13.
Acta physiol. pharmacol. latinoam ; 38(1): 19-25, ene.-mar. 1988. ilus
Artigo em Espanhol | BINACIS | ID: bin-27285

RESUMO

Se ha registrado, mediante sensores piezoelétricos, la variación del estado contráctil consecuente a la hipertensión pulmonar aguda severa, provocada en corazones normales de perros por la estenosis experimental de la arteria pulmonar. Durante el proceso de la estenosis se aprecia, por una parte, un incremento proporcional sólo de la tensión isométrica de la pared del ventrículo derecho y del "kick" auricular, debidos a la dificultad creciente en la evacuación del contenido sanguíneo de ambas cavidades, y por otra parte, la pérdida de la distensibilidad de la pared, que al tornarse más rígida, limita el desarrollo de las presiones sistólica y diastólica del ventículo derecho. En tanto, el sensor isquierdo, describe las variaciones consecuentes a la contracción de dicha pared ventricular (AU)


Assuntos
Cães , Animais , Masculino , Feminino , Hipertensão Pulmonar/fisiopatologia , Contração Miocárdica , Estenose da Valva Pulmonar/fisiopatologia , Doença Aguda
14.
Acta physiol. pharmacol. latinoam ; 36(4): 377-90, 1986. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-44842

RESUMO

Se analizan con sensores piezoeléctricos, implantados en la superficie del ventrículo izquierdo, las alteraciones mecánicas de la pared ventricular, originadas en el aumento de la postcarga provocada con estenosis aórticas experimentales agudas y crónicas. La tensión o fuerza desarrollada por la pared ventricular o la aceleración de la velocidad de acortamiento del elemento contráctil muestran en estas condiciones, en la curva del sensor piezoeléctrico, un nuevo estado contáctil característico de la rapidez de instalación y del tiempo transcurrido desde la estenosis aórtica. Se puede así sugerir, mediante el análisis de las curvas con el sensor piezoeléctrico, su diagnóstico, sus picos sistólicos y su tiempo de evolución. Se describen, además apelando a las variaciones que muestran las distintas fases del ciclo cardíaco en las curvas del sensor, los diferentes mecanismos de adaptación utilizados por el miocardio según cual sea la rapidez de instalación de la estenosis experimental


Assuntos
Cães , Animais , Masculino , Feminino , Pressão Arterial , Estenose da Valva Aórtica/fisiopatologia , Contração Miocárdica , Eletrocardiografia , Eletrodos Implantados , Frequência Cardíaca
15.
Acta physiol. pharmacol. latinoam ; 36(4): 377-90, 1986. ilus, Tab
Artigo em Espanhol | BINACIS | ID: bin-31567

RESUMO

Se analizan con sensores piezoeléctricos, implantados en la superficie del ventrículo izquierdo, las alteraciones mecánicas de la pared ventricular, originadas en el aumento de la postcarga provocada con estenosis aórticas experimentales agudas y crónicas. La tensión o fuerza desarrollada por la pared ventricular o la aceleración de la velocidad de acortamiento del elemento contráctil muestran en estas condiciones, en la curva del sensor piezoeléctrico, un nuevo estado contáctil característico de la rapidez de instalación y del tiempo transcurrido desde la estenosis aórtica. Se puede así sugerir, mediante el análisis de las curvas con el sensor piezoeléctrico, su diagnóstico, sus picos sistólicos y su tiempo de evolución. Se describen, además apelando a las variaciones que muestran las distintas fases del ciclo cardíaco en las curvas del sensor, los diferentes mecanismos de adaptación utilizados por el miocardio según cual sea la rapidez de instalación de la estenosis experimental (AU)


Assuntos
Cães , Animais , Masculino , Feminino , Contração Miocárdica , Estenose da Valva Aórtica/fisiopatologia , Pressão Sanguínea , Eletrocardiografia , Eletrodos Implantados , Frequência Cardíaca
16.
Acta physiol. pharmacol. latinoam ; 35(2): 217-22, abr.-jun. 1985. ilus
Artigo em Espanhol | LILACS | ID: lil-1631

RESUMO

Se describe un nuevo método empleado para el registro, mediante sensores piezoeléctricos, de la fuerza desarrollada o de la aceleración de la velocidad de acortamiento del elemento contráctil, a través de todo el ciclo cardíaco. La actividad normal del elemento contráctil muestra diferentes aspectos en ambos ventrículos. La curva SPz del ventrículo derecho es comparada con la curva SPz correspondiente al ventrículo izquierdo. La primera curva muestra que la eyección de sangre a la arteria pulmonar es debida, esencialmente, a la Fuerza desarrollada o a la aceleración de la velocidad de acortamiento del elemento contráctil, durante la fase de contracción isométrica del ciclo cardíaco. El período de eyección, con una velocidad de acortamiento bastante constante, parece completar la expulsión de la sangre. El flujo sanguíneo ventricular izquierdo hacia el circuito sistémico es debido principalmente a la fase de eyección temprana, donde la fuerza desarrollada o la aceleración de la velocidad de acortamiento del elemento contráctil parece ser mayor, para impulsar la sangre hacia la arteria aorta


Assuntos
Cães , Animais , Masculino , Feminino , Eletrocardiografia , Hemodinâmica , Contração Miocárdica , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Volume Sistólico , Ventrículos do Coração/fisiologia
17.
Acta physiol. pharmacol. latinoam ; 35(2): 217-22, abr.-jun. 1985. ilus
Artigo em Espanhol | BINACIS | ID: bin-36969

RESUMO

Se describe un nuevo método empleado para el registro, mediante sensores piezoeléctricos, de la fuerza desarrollada o de la aceleración de la velocidad de acortamiento del elemento contráctil, a través de todo el ciclo cardíaco. La actividad normal del elemento contráctil muestra diferentes aspectos en ambos ventrículos. La curva SPz del ventrículo derecho es comparada con la curva SPz correspondiente al ventrículo izquierdo. La primera curva muestra que la eyección de sangre a la arteria pulmonar es debida, esencialmente, a la Fuerza desarrollada o a la aceleración de la velocidad de acortamiento del elemento contráctil, durante la fase de contracción isométrica del ciclo cardíaco. El período de eyección, con una velocidad de acortamiento bastante constante, parece completar la expulsión de la sangre. El flujo sanguíneo ventricular izquierdo hacia el circuito sistémico es debido principalmente a la fase de eyección temprana, donde la fuerza desarrollada o la aceleración de la velocidad de acortamiento del elemento contráctil parece ser mayor, para impulsar la sangre hacia la arteria aorta (AU)


Assuntos
Cães , Animais , Masculino , Feminino , Contração Miocárdica , Eletrocardiografia , Hemodinâmica , Pressão Sanguínea , Velocidade do Fluxo Sanguíneo , Ventrículos do Coração/fisiologia , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...