Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 180(1-4): 391-394, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29688547

RESUMO

The Neutron Standards Laboratory of CIEMAT has conducted the characterization of the independent spent fuel storage installation at the Trillo Nuclear Power Plant. At this facility, the spent fuel assemblies are stored in ENSA-DPT type dual purpose casks. Neutron characterization was performed by dosimetry measurements with a neutron survey meter (LB6411) inside the facility, around an individual cask and between stored casks, and outside the facility. Spectra measurements were also performed with a Bonner sphere system in order to determine the integral quantities and validate the use of the neutron monitor at the different positions. Inside the facility, measured neutron spectra and neutron ambient dose equivalent rate are consistent with the casks spatial distribution and neutron emission rates, and measurements with both instruments are consistent with each other. Outside the facility, measured neutron ambient dose equivalent rates are well below the 0.5 µSv/h limit established by the nuclear regulatory authority.


Assuntos
Nêutrons , Centrais Nucleares , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Resíduos Radioativos/análise , Simulação por Computador , Desenho de Equipamento , Humanos , Método de Monte Carlo , Doses de Radiação , Proteção Radiológica/métodos
2.
Appl Radiat Isot ; 117: 58-64, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26994753

RESUMO

The response of a scintillation neutron detector of ZnS(Ag) with 10B was calculated, using the MCNPX Monte Carlo Code. The detector consists of four panels of polymethyl methacrylate (PMMA) and five thin layers of ~0.017cm thick 10B+ZnS(Ag) in contact with the PMMA. The response was calculated for the bare detector and with different thicknesses of High Density Polyethylene, HDPE, moderator for 29 monoenergetic sources as well as 241AmBe and 252Cf neutrons sources. In these calculations the reaction rate 10B(n, α)7Li and the neutron fluence in the sensitive area of the detector 10B+ZnS(Ag) was estimated. Measurements were made at the Neutron Measurements Laboratory, Universidad Politécnica de Madrid, LMN-UPM, to quantify the detections in counts per second in response to a 252Cf neutron source separated 200cm. The MCNPX computations were compared with measurements to estimate the efficiency of ZnS(Ag) for detecting the α that is created in the 10B(n, α)7Li reaction. After validating new models with different geometries it will be possible to improve the detector response trying to achieve a sensitivity of 2.5cps-ng252Cf comparable with the response requirements for 3He detectors installed in the Radiation Portal Monitors, RPMs. This type of detector can be considered an alternative to the 3He detectors for detection of Special Nuclear Material, SNM.

3.
Appl Radiat Isot ; 100: 84-90, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25468287

RESUMO

Monte Carlo calculations were carried out to characterize the neutron field produced by the calibration neutron sources of the Neutron Standards Laboratory at the Research Center for Energy, Environment, and Technology (CIEMAT) in Spain. For (241)AmBe and (252)Cf neutron sources, the neutron spectra, the ambient dose equivalent rates and the total neutron fluence rates were estimated. In the calibration hall, there are several items that modify the neutron field. To evaluate their effects different cases were used, from point-like source in vacuum up to the full model. Additionally, using the full model, the neutron spectra were estimated to different distances along the bench; with these spectra, the total neutron fluence and the ambient dose equivalent rates were calculated. The hall walls induce the largest changes in the neutron spectra and the respective integral quantities. The free-field neutron spectrum is modified due the room return effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...