Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Neurophysiol ; 141: 119-125, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-33972159

RESUMO

OBJECTIVE: EEG source imaging (ESI) is a validated tool in the multimodal workup of patients with drug resistant focal epilepsy. However, it requires special expertise and it is underutilized. To circumvent this, automated analysis pipelines have been developed and validated for the interictal discharges. In this study, we present the clinical validation of an automated ESI for ictal EEG signals. METHODS: We have developed an automated analysis pipeline of ictal EEG activity, based on spectral analysis in source space, using an individual head model of six tissues. The analysis was done blinded to all other data. As reference standard, we used the concordance with the resected area and one-year postoperative outcome. RESULTS: We analyzed 50 consecutive patients undergoing epilepsy surgery (34 temporal and 16 extra-temporal). Thirty patients (60%) became seizure-free. The accuracy of the automated ESI was 74% (95% confidence interval: 59.66-85.37%). CONCLUSIONS: Automated ictal ESI has a high accuracy for localizing the seizure onset zone. SIGNIFICANCE: Automating the ESI of the ictal EEG signals will facilitate implementation of this tool in the presurgical evaluation.


Assuntos
Epilepsia Resistente a Medicamentos , Eletroencefalografia , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia/métodos , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Convulsões/diagnóstico por imagem , Convulsões/cirurgia
2.
Neuro Oncol ; 21(12): 1595-1606, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31618420

RESUMO

BACKGROUND: Diagnostic accuracy in previous studies of O-(2-[18F]-fluoroethyl)-L-tyrosine (18F-FET) PET in patients with suspected recurrent glioma may be influenced by prolonged dynamic PET acquisitions, heterogeneous populations, different non-standard-of-care therapies, and PET scans performed at different time points post radiotherapy. We investigated the diagnostic accuracy of a 20-minute 18F-FET PET scan in MRI-suspected recurrent glioblastoma 6 months after standard radiotherapy and its ability to prognosticate overall survival (OS). METHODS: In total, 146 glioblastoma patients with 168 18F-FET PET scans were reviewed retrospectively. Patients with MRI responses to bevacizumab or undergoing re-irradiation or immunotherapy after 18F-FET PET were excluded. Maximum and mean tumor-to-background ratios (TBRmax, TBRmean) and biological tumor volume (BTV) were recorded and verified by histopathology or clinical/radiological follow-up. Thresholds of 18F-FET parameters were determined by receiver operating characteristic (ROC) analysis. Prognostic factors were investigated in Cox proportional hazards models. RESULTS: Surgery was performed after 104 18F-FET PET scans, while clinical/radiological surveillance was used following 64, identifying 152 glioblastoma recurrences and 16 posttreatment changes. ROC analysis yielded thresholds of 2.0 for TBRmax, 1.8 for TBRmean, and 0.55 cm3 for BTV in differentiating recurrent glioblastoma from posttreatment changes with the best performance of TBRmax (sensitivity 99%, specificity 94%; P < 0.0001) followed by BTV (sensitivity 98%, specificity 94%; P < 0.0001). Using these thresholds, 166 18F-FET PET scans were correctly classified. Increasing BTV was associated with shorter OS (P < 0.0001). CONCLUSION: A 20-minute 18F-FET PET scan is a powerful tool to distinguish posttreatment changes from recurrent glioblastoma 6-month postradiotherapy, and predicts OS.


Assuntos
Neoplasias Encefálicas/patologia , Glioblastoma/patologia , Recidiva Local de Neoplasia/patologia , Tomografia por Emissão de Pósitrons/métodos , Tirosina/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/terapia , Quimiorradioterapia/mortalidade , Terapia Combinada , Feminino , Seguimentos , Glioblastoma/diagnóstico por imagem , Glioblastoma/metabolismo , Glioblastoma/terapia , Humanos , Imunoterapia/mortalidade , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/metabolismo , Recidiva Local de Neoplasia/terapia , Prognóstico , Compostos Radiofarmacêuticos/metabolismo , Estudos Retrospectivos , Taxa de Sobrevida , Tirosina/metabolismo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...