Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Dental Press J Orthod ; 29(2): e2423212, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38865514

RESUMO

OBJECTIVE: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). METHODS: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. RESULTS: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. CONCLUSIONS: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.


Assuntos
Desenho de Aparelho Ortodôntico , Polietilenotereftalatos , Poliuretanos , Técnicas de Movimentação Dentária , Humanos , Estudos Retrospectivos , Adulto , Feminino , Técnicas de Movimentação Dentária/instrumentação , Masculino , Poliuretanos/uso terapêutico , Polietilenoglicóis , Arco Dental , Aparelhos Ortodônticos Removíveis , Adulto Jovem
2.
Dental Press J Orthod ; 29(2): e2423237, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775600

RESUMO

OBJECTIVE: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. METHODS: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. RESULTS: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. CONCLUSION: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.


Assuntos
Técnicas de Movimentação Dentária , Humanos , Técnicas de Movimentação Dentária/instrumentação , Estudos Retrospectivos , Adulto , Rotação , Feminino , Masculino , Desenho de Aparelho Ortodôntico , Incisivo , Modelos Dentários , Aparelhos Ortodônticos Removíveis , Arco Dental
3.
Dental press j. orthod. (Impr.) ; 29(2): e2423212, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557692

RESUMO

ABSTRACT Objective: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). Methods: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. Results: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. Conclusions: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.


RESUMO Objetivo: O objetivo deste estudo retrospectivo foi comparar a acurácia na expansão da arcada utilizando alinhadores Invisalign com dois tipos de material termoplástico: EX30® (Polietileno Tereftalato Glicol, ou PETG) e SmartTrack® (poliuretano). Método: A amostra desse estudo incluiu 65 pacientes adultos tratados consecutivamente em dois consultórios particulares: grupo 1 - tratado com EX30® (358 dentes), e grupo 2 - tratado com SmartTrack® (888 dentes). Foram avaliadas 623 medidas em três pares de modelos digitais, ao longo do tratamento: modelo 1 - inicial, modelo 2 - posição dentária planejada, modelo 3 - posição alcançada. Foram marcados 16 pontos de referência por arcada e, após o bestfit, 2 pontos por arcada foram copiados de um modelo digital para o outro. Medidas lineares de ambas as arcadas foram aferidas para caninos, pré-molares e primeiros molares, localizadas na margem gengival lingual e ponta de cúspide de todos os dentes. Foram realizadas comparações usando os testes Wilcoxon e Mann-Whitney. Resultados: Ambos os materiais termoplásticos apresentaram diferenças significativas entre os valores planejados e alcançados em todas as medidas, exceto na ponta de cúspide dos primeiros molares inferiores do grupo SmartTrack®. Não houve diferença estatística entre esses dois materiais quanto à acurácia da expansão transversa. Em termos gerais, a acurácia dos alinhadores EX30® na maxila e mandíbula foi de 37% e 38%, respectivamente. O grupo SmartTrack® apresentou acurácia de 56,62% e 68,72% na maxila e mandíbula, respectivamente. Conclusões: Não foi possível afirmar que um material expande melhor que o outro. Estudos clínicos controlados futuros devem ser conduzidos comparando SmartTrack® e EX30® sob condições similares.

4.
Dental press j. orthod. (Impr.) ; 29(2): e2423237, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557693

RESUMO

ABSTRACT Objective: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. Methods: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. Results: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. Conclusion: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.


RESUMO Objetivo: Esse estudo retrospectivo teve como objetivo aferir a previsibilidade dos alinhadores Invisalign em relação aos movimentos de rotação e inclinações mesiodistal e vestibulolingual. Material e Métodos: Foram incluídos dois materiais nessa análise: EX30®, utilizado até 2013; e SmartTrack®, atualmente em uso. Esse estudo avaliou 56 pacientes tratados com Invisalign Comprehensive. Os dados foram avaliados em três pares de modelos digitais; modelo 1 - inicial, modelo 2 - planejado, e modelo 3 - alcançado. Foram marcados 60 pontos de referência em cada arcada, sendo a sobreposição realizada com auxílio de planos de referência. O grau de rotação e inclinações mesiodistal e vestibulolingual foi obtido por cálculos de trigonometria, usando um método validado publicado anteriormente. Os resultados foram comparados de acordo com os tipos de movimento dentário e grupos de dentes, também foi investigada a influência de variáveis predeterminadas na confiabilidade dos movimentos. Resultados: Os movimentos de rotação e inclinação mesiodistal não apresentaram diferença estatística, quando comparados os grupos EX30® e SmartTrack®. Somente a inclinação vestibulolingual apresentou diferença estatisticamente significativa, sendo que os grupos de incisivos e caninos tratados com alinhadores EX30® apresentaram um aumento na previsibilidade(p= 0,007 e p= 0,007, respectivamente). Para cada grau adicional planejado para movimento de rotação, ocorreu um aumento de 0,35° na discrepância, e aumentos de 0,40° e 0,41° para as inclinações mesiodistal e vestibulolingual, respectivamente. As discrepâncias entre EX30® e SmartTrack® foram comparadas por regressão linear multinível. Conclusão: Os alinhadores EX30® alcançaram maior previsibilidade para a inclinação vestibulolingual em dentes anteriores. No entanto, para rotação e inclinação mesiodistal, SmartTrack® e EX30® apresentaram previsibilidade similar. A quantidade total de movimento planejado apresenta influência significativa nas taxas de previsibilidade, com diminuição na acurácia para cada grau adicional.

5.
Dental Press J Orthod ; 20(2): 22-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25992983

RESUMO

Dr. Frazier-Bowers is an associate professor at the University of North Carolina, Chapel Hill (UNC-CH), in the Department of Orthodontics. She received a BA from the University of Illinois, Urbana-Champaign, and a DDS from the University of Illinois, Chicago. After completing the NIH Dentist-Scientist Program at UNC-CH in Orthodontics (Certificate, 97') and Genetics and Molecular Biology (PhD, 99'), she completed a post-doctoral fellowship at the University of Texas Health Science Center, Houston (UTHSC), in the Department of Orthodontics. Leadership positions include president of local NC-AADR (North Carolina (2005-2006); director of the AADR Craniofacial Biology group (CBG) 2004-2007; IADR/AADR councilor for NC-AADR (2007, 2008, 2012) and for the CBG (2012-2015); member of Southern Association of Orthodontists Scientific Affairs Committee (2005-2013) and the American Association of Orthodontists Council on Scientific Affairs (2014 ­ Present). Dr. Frazier-Bowers also serves various editorial boards including the Journal of Dental Research and the Scientific Advisory board for the Consortium on Orthodontic Advances in Science and Technology. Her current role as faculty at UNC-CH includes conducting human genetic studies to determine the etiology of inherited tooth disorders, mentoring students at all levels, teaching graduate and pre-doctoral level Growth and Development courses and treating patients in the UNC School of Dentistry faculty practice in Orthodontics.


Assuntos
Má Oclusão Classe III de Angle/terapia , Ortodontia Corretiva/métodos , Mapeamento Cromossômico , Análise por Conglomerados , Previsões , Interação Gene-Ambiente , Heterogeneidade Genética , Humanos , Imageamento Tridimensional/métodos , Má Oclusão Classe III de Angle/classificação , Má Oclusão Classe III de Angle/genética , Maxila/anormalidades , Desenvolvimento Maxilofacial/fisiologia , Fenótipo , Medicina de Precisão , Prognatismo/classificação , Anquilose Dental/fisiopatologia , Erupção Dentária/fisiologia , Dente Impactado/fisiopatologia
6.
Am J Orthod Dentofacial Orthop ; 132(3): 400-7, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17826611

RESUMO

This case report describes the treatment of a 25-year-old woman with anterior open bite, Class II skeletal malocclusion, and a history of temporomandibular joint pain and sounds. She also had significant anteroposterior and vertical discrepancies and a convex profile with protrusive lips. Intraorally, she had an anterior open bite of 3 mm and an overjet of 5 mm. Mandibular surgical rotation, associated with mandibular incisor extraction, was performed to reduce the protrusion, close the open bite, and minimize the temporomandibular joint disorder.


Assuntos
Má Oclusão Classe II de Angle/cirurgia , Mandíbula/cirurgia , Avanço Mandibular/métodos , Transtornos da Articulação Temporomandibular/cirurgia , Adulto , Cefalometria , Feminino , Humanos , Má Oclusão Classe II de Angle/complicações , Mordida Aberta/complicações , Mordida Aberta/cirurgia , Ortodontia Corretiva/métodos , Transtornos da Articulação Temporomandibular/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...